| Name | AT0NDmvHS48n9Rq4apOajLDm4fhM0noT9bVo0NGKDmlJ2KDmZk11Qo_2 |
| Workunit | 238714183 |
| Created | 27 Jan 2026, 4:22:52 UTC |
| Sent | 27 Jan 2026, 4:33:20 UTC |
| Report deadline | 4 Feb 2026, 4:33:20 UTC |
| Received | 27 Jan 2026, 4:44:38 UTC |
| Server state | Over |
| Outcome | Computation error |
| Client state | Compute error |
| Exit status | 1 (0x00000001) Unknown error code |
| Computer ID | 10669625 |
| Run time | 20 sec |
| CPU time | 0 sec |
| Priority | 28 |
| Validate state | Invalid |
| Credit | 0.00 |
| Device peak FLOPS | 5.72 GFLOPS |
| Application version | ATLAS Simulation v3.03 (vbox64_mt_mcore_atlas) windows_x86_64 |
| Peak working set size | 11.25 MB |
| Peak swap size | 6.28 MB |
| Peak disk usage | 482.64 MB |
<core_client_version>8.2.8</core_client_version>
<![CDATA[
<message>
Unzul�ssige Funktion.
(0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2026-01-27 05:39:24 (5988): vboxwrapper version 26210
2026-01-27 05:39:24 (5988): BOINC client version: 8.2.8
2026-01-27 05:39:25 (5988): Detected: VirtualBox VboxManage Interface (Version: 7.2.4)
2026-01-27 05:39:26 (5988): Successfully copied 'init_data.xml' to the shared directory.
2026-01-27 05:39:26 (5988): Create VM. (boinc_39d9720756dcce79, slot#3)
2026-01-27 05:39:26 (5988): Setting Memory Size for VM. (4800MB)
2026-01-27 05:39:27 (5988): Setting CPU Count for VM. (8)
2026-01-27 05:39:27 (5988): Setting Chipset Options for VM.
2026-01-27 05:39:27 (5988): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB)
2026-01-27 05:39:27 (5988): Setting Boot Options for VM.
2026-01-27 05:39:28 (5988): Setting Network Configuration for NAT. (Driver: virtio)
2026-01-27 05:39:28 (5988): Enabling VM Network Access.
2026-01-27 05:39:28 (5988): Disabling USB Support for VM.
2026-01-27 05:39:29 (5988): Disabling COM Port Support for VM.
2026-01-27 05:39:29 (5988): Disabling LPT Port Support for VM.
2026-01-27 05:39:29 (5988): Disabling Audio Support for VM.
2026-01-27 05:39:30 (5988): Disabling Clipboard Support for VM.
2026-01-27 05:39:30 (5988): Disabling Drag and Drop Support for VM.
2026-01-27 05:39:30 (5988): Adding storage controller(s) to VM.
2026-01-27 05:39:30 (5988): Adding virtual disk drive to VM. (ATLAS_vbox_3.03_image.vdi)
2026-01-27 05:39:32 (5988): Adding VirtualBox Guest Additions to VM.
2026-01-27 05:39:33 (5988): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2026-01-27 05:39:33 (5988): forwarding host port 56974 to guest port 80
2026-01-27 05:39:33 (5988): Enabling remote desktop for VM.
2026-01-27 05:39:34 (5988): Enabling shared directory for VM.
2026-01-27 05:39:35 (5988): Starting VM using VBoxManage interface. (boinc_39d9720756dcce79, slot#3)
2026-01-27 05:39:37 (5988): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_39d9720756dcce79" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_39d9720756dcce79' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_39d9720756dcce79" to power on...
2026-01-27 05:39:37 (5988): VM failed to start.
2026-01-27 05:39:37 (5988): Could not start
2026-01-27 05:39:37 (5988): ERROR: VM failed to start
2026-01-27 05:39:37 (5988): Powering off VM.
2026-01-27 05:39:37 (5988): Deregistering VM. (boinc_39d9720756dcce79, slot#3)
2026-01-27 05:39:37 (5988): Removing network bandwidth throttle group from VM.
2026-01-27 05:39:37 (5988): Removing VM from VirtualBox.
Hypervisor System Log:
00:00:07.699664 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:07.713502 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:07.713690 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.715981 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:07.719130 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:07.719691 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:07.722311 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:07.971265 Platform architecture set to 'x86'
00:00:07.973069 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.973480 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.974123 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:07.987966 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:08.234808 Platform architecture set to 'x86'
00:00:08.236244 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:08.240962 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:08.498594 Platform architecture set to 'x86'
00:00:08.500695 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:08.514039 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:09.029256 Platform architecture set to 'x86'
00:00:09.030815 VRDE: Generating certificate files 'C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\VRDEAutoGeneratedCert.pem' and 'C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\VRDEAutoGeneratedPrivateKey.pem'...
00:00:09.135464 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:09.148868 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:09.299903 Platform architecture set to 'x86'
00:00:09.301205 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:09.304448 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:09.564650 Platform architecture set to 'x86'
00:00:09.566195 ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0
00:00:09.571981 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.572058 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.787154 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={83cfdc66-4f20-4569-ad39-8722f7d472b3} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0
00:00:09.788066 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.088116 Launched VM: 2434241712 pid: 17012 (0x4274) frontend: headless name: boinc_39d9720756dcce79
00:00:12.592493 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The virtual machine 'boinc_39d9720756dcce79' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:12.644701 Platform architecture set to 'x86'
00:00:12.645420 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.690138 Platform architecture set to 'x86'
00:00:12.691351 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox" with version "1.19-windows"
00:00:12.704889 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\boinc_39d9720756dcce79.vbox"
00:00:12.959405 Saving settings file "C:\Users\Egon Olsen\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.973176 Finished saving settings file "C:\Users\Egon Olsen\.VirtualBox\VirtualBox.xml"
00:00:12.973419 Saving settings file "C:\Users\Egon Olsen\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.977124 Finished saving settings file "C:\Users\Egon Olsen\.VirtualBox\VirtualBox.xml"
00:00:12.978134 DeleteVM Saving settings file "C:\Users\Egon Olsen\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.981382 DeleteVM Finished saving settings file "C:\Users\Egon Olsen\.VirtualBox\VirtualBox.xml"
00:00:17.994555 main VirtualBox: object deletion starts
00:00:17.994626 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={7d510820-a678-4730-a862-818dcd3fbed0} aComponent={MediumWrap} aText={Medium 'C:\Users\Egon Olsen\VirtualBox VMs\Arbeit10\Arbeit10.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:17.995212 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={7d510820-a678-4730-a862-818dcd3fbed0} aComponent={MediumWrap} aText={Medium 'C:\Users\Egon Olsen\VirtualBox VMs\Tuxedo\Tuxedo.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:17.997093 main HostDnsMonitor: shutting down ...
00:00:17.997134 main HostDnsMonitor: shut down
00:00:17.998743 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={2ce10519-3c09-45d8-a12d-e887786146b7} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.999087 main VirtualBox: object deleted
VM Execution Log:
VM Startup Log:
VM Trace Log:
79-screen0.webm"
rec_screen_opts="ac_profile=med"
rec_screen_video_res_xy="1024x768"
rec_screen_video_rate_kbps=512
rec_screen_video_fps=25
description="AT0NDmvHS48n9Rq4apOajLDm4fhM0noT9bVo0NGKDmlJ2KDmZk11Qo_2"
GuestMemoryBalloon=0
2026-01-27 05:39:28 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on
Exit Code: 0
Output:
2026-01-27 05:39:28 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --cable-connected1 on
Exit Code: 0
Output:
2026-01-27 05:39:29 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --usb off
Exit Code: 0
Output:
2026-01-27 05:39:29 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --uart1 off --uart2 off
Exit Code: 0
Output:
2026-01-27 05:39:29 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --lpt1 off --lpt2 off
Exit Code: 0
Output:
2026-01-27 05:39:30 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --audio-enabled off
Exit Code: 0
Output:
2026-01-27 05:39:30 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --clipboard disabled
Exit Code: 0
Output:
2026-01-27 05:39:30 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --draganddrop disabled
Exit Code: 0
Output:
2026-01-27 05:39:30 (5988):
Command: VBoxManage -q storagectl "boinc_39d9720756dcce79" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:
2026-01-27 05:39:31 (5988):
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
UUID: 3e56213b-898f-4e83-899f-8eb541d45260
Parent UUID: base
State: created
Type: multiattach
Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20480 MBytes
Size on disk: 4204 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
2026-01-27 05:39:31 (5988):
Command: VBoxManage -q storageattach "boinc_39d9720756dcce79" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp
2026-01-27 05:39:31 (5988):
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
UUID: 3e56213b-898f-4e83-899f-8eb541d45260
Parent UUID: base
State: created
Type: multiattach
Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20480 MBytes
Size on disk: 4204 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
2026-01-27 05:39:31 (5988):
Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
2026-01-27 05:39:32 (5988):
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
UUID: 3e56213b-898f-4e83-899f-8eb541d45260
Parent UUID: base
State: created
Type: normal (base)
Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20480 MBytes
Size on disk: 4204 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
2026-01-27 05:39:32 (5988):
Command: VBoxManage -q storageattach "boinc_39d9720756dcce79" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
2026-01-27 05:39:32 (5988):
Command: VBoxManage -q storageattach "boinc_39d9720756dcce79" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none
Exit Code: 0
Output:
2026-01-27 05:39:32 (5988):
Command: VBoxManage -q storageattach "boinc_39d9720756dcce79" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
2026-01-27 05:39:33 (5988):
Command: VBoxManage -q storageattach "boinc_39d9720756dcce79" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso"
Exit Code: 0
Output:
2026-01-27 05:39:33 (5988):
Command: VBoxManage -q bandwidthctl "boinc_39d9720756dcce79" add "boinc_39d9720756dcce79_net" --type network --limit 1024G
Exit Code: 0
Output:
2026-01-27 05:39:33 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --natpf1 ",tcp,127.0.0.1,56974,,80"
Exit Code: 0
Output:
2026-01-27 05:39:34 (5988):
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 2
Pack no. 0: Oracle VirtualBox Extension Pack
Version: 7.2.4
Revision: 170995
Edition:
Description: Oracle Cloud Infrastructure integration, VirtualBox RDP, PXE ROM, Disk Encryption, full VM encryption.
VRDE Module: VBoxVRDP
Crypto Module: VBoxPuelCrypto
Usable: true
Why unusable:
Pack no. 1: Oracle VM VirtualBox Extension Pack
Version: 7.0.20
Revision: 163906
Edition:
Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption.
VRDE Module: VBoxVRDP
Crypto Module: VBoxPuelCrypto
Usable: false
Why unusable: VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='VirtualBox version mismatch - expected 7.0 got 7.2'
2026-01-27 05:39:34 (5988):
Command: VBoxManage -q modifyvm "boinc_39d9720756dcce79" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 56975 --vrde-property "Security/Method=RDP"
Exit Code: 0
Output:
2026-01-27 05:39:34 (5988):
Command: VBoxManage -q sharedfolder add "boinc_39d9720756dcce79" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared"
Exit Code: 0
Output:
2026-01-27 05:39:37 (5988):
Command: VBoxManage -q startvm "boinc_39d9720756dcce79" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_39d9720756dcce79' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_39d9720756dcce79\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_39d9720756dcce79" to power on...
2026-01-27 05:39:37 (5988):
Command: VBoxManage -q snapshot "boinc_39d9720756dcce79" list
Exit Code: -108
Output:
This machine does not have any snapshots
2026-01-27 05:39:37 (5988):
Command: VBoxManage -q bandwidthctl "boinc_39d9720756dcce79" remove "boinc_39d9720756dcce79_net"
Exit Code: 0
Output:
2026-01-27 05:39:38 (5988):
Command: VBoxManage -q unregistervm "boinc_39d9720756dcce79" --delete
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%
2026-01-27 05:39:43 (5988): called boinc_finish(1)
</stderr_txt>
]]>
©2026 CERN