| Name | 5LBMDmzQY38nsSi4ap6QjLDmwznN0nGgGQJmNLGKDmM02KDmRpNv0n_0 |
| Workunit | 238654976 |
| Created | 23 Jan 2026, 15:45:37 UTC |
| Sent | 23 Jan 2026, 19:34:15 UTC |
| Report deadline | 31 Jan 2026, 19:34:15 UTC |
| Received | 23 Jan 2026, 19:42:44 UTC |
| Server state | Over |
| Outcome | Computation error |
| Client state | Compute error |
| Exit status | 1 (0x00000001) Unknown error code |
| Computer ID | 10644698 |
| Run time | 22 sec |
| CPU time | 0 sec |
| Priority | 28 |
| Validate state | Invalid |
| Credit | 0.00 |
| Device peak FLOPS | 33.56 GFLOPS |
| Application version | ATLAS Simulation v3.03 (vbox64_mt_mcore_atlas) windows_x86_64 |
| Peak working set size | 7.69 MB |
| Peak swap size | 1.84 MB |
| Peak disk usage | 480.38 MB |
<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Incorrect function.
(0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2026-01-23 19:40:28 (14836): vboxwrapper version 26210
2026-01-23 19:40:28 (14836): BOINC client version: 8.0.2
2026-01-23 19:40:30 (14836): Detected: VirtualBox VboxManage Interface (Version: 7.2.4)
2026-01-23 19:40:30 (14836): Successfully copied 'init_data.xml' to the shared directory.
2026-01-23 19:40:30 (14836): Create VM. (boinc_4fbb7b6178a94f4f, slot#0)
2026-01-23 19:40:32 (14836): Setting Memory Size for VM. (4600MB)
2026-01-23 19:40:32 (14836): Setting CPU Count for VM. (6)
2026-01-23 19:40:32 (14836): Setting Chipset Options for VM.
2026-01-23 19:40:33 (14836): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB)
2026-01-23 19:40:33 (14836): Setting Boot Options for VM.
2026-01-23 19:40:33 (14836): Setting Network Configuration for NAT. (Driver: virtio)
2026-01-23 19:40:34 (14836): Enabling VM Network Access.
2026-01-23 19:40:34 (14836): Disabling USB Support for VM.
2026-01-23 19:40:34 (14836): Disabling COM Port Support for VM.
2026-01-23 19:40:34 (14836): Disabling LPT Port Support for VM.
2026-01-23 19:40:35 (14836): Disabling Audio Support for VM.
2026-01-23 19:40:35 (14836): Disabling Clipboard Support for VM.
2026-01-23 19:40:35 (14836): Disabling Drag and Drop Support for VM.
2026-01-23 19:40:35 (14836): Adding storage controller(s) to VM.
2026-01-23 19:40:36 (14836): Adding virtual disk drive to VM. (ATLAS_vbox_3.03_image.vdi)
2026-01-23 19:40:38 (14836): Adding VirtualBox Guest Additions to VM.
2026-01-23 19:40:38 (14836): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2026-01-23 19:40:38 (14836): forwarding host port 11507 to guest port 80
2026-01-23 19:40:39 (14836): Enabling remote desktop for VM.
2026-01-23 19:40:39 (14836): Enabling shared directory for VM.
2026-01-23 19:40:40 (14836): Starting VM using VBoxManage interface. (boinc_4fbb7b6178a94f4f, slot#0)
2026-01-23 19:40:41 (14836): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_4fbb7b6178a94f4f" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_4fbb7b6178a94f4f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'D:\Data\slots\0\boinc_4fbb7b6178a94f4f\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_4fbb7b6178a94f4f" to power on...
2026-01-23 19:40:41 (14836): VM failed to start.
2026-01-23 19:40:41 (14836): Could not start
2026-01-23 19:40:41 (14836): ERROR: VM failed to start
2026-01-23 19:40:41 (14836): Powering off VM.
2026-01-23 19:40:41 (14836): Deregistering VM. (boinc_4fbb7b6178a94f4f, slot#0)
2026-01-23 19:40:41 (14836): Removing network bandwidth throttle group from VM.
2026-01-23 19:40:42 (14836): Removing VM from VirtualBox.
Hypervisor System Log:
00:00:08.696859 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:08.697079 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.699500 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:08.732632 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:08.733243 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:08.763435 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:08.925074 Platform architecture set to 'x86'
00:00:08.927184 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.927582 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.928121 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:08.952641 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:09.200254 Platform architecture set to 'x86'
00:00:09.201640 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:09.238148 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:09.462221 Platform architecture set to 'x86'
00:00:09.464683 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:09.506737 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:09.982687 Platform architecture set to 'x86'
00:00:09.984240 VRDE: Generating certificate files 'D:\Data\slots\0\boinc_4fbb7b6178a94f4f\VRDEAutoGeneratedCert.pem' and 'D:\Data\slots\0\boinc_4fbb7b6178a94f4f\VRDEAutoGeneratedPrivateKey.pem'...
00:00:10.026846 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:10.180574 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:10.514105 Platform architecture set to 'x86'
00:00:10.515355 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:10.549754 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:10.778206 Platform architecture set to 'x86'
00:00:10.780024 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={2ce10519-3c09-45d8-a12d-e887786146b7} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:10.786315 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.786397 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.792416 WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={d5dcece0-b202-4416-a138-03502784cc07} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND). The service might not be installed on the host computer}, preserve=true aResultDetail=0
00:00:10.792528 WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={d5dcece0-b202-4416-a138-03502784cc07} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND). The service might not be installed on the host computer}, preserve=true aResultDetail=0
00:00:10.794616 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={83cfdc66-4f20-4569-ad39-8722f7d472b3} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0
00:00:10.795599 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.082269 Launched VM: 1085078912 pid: 8188 (0x1ffc) frontend: headless name: boinc_4fbb7b6178a94f4f
00:00:12.326725 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The virtual machine 'boinc_4fbb7b6178a94f4f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'D:\Data\slots\0\boinc_4fbb7b6178a94f4f\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:12.443285 Platform architecture set to 'x86'
00:00:12.444225 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.502109 Platform architecture set to 'x86'
00:00:12.504673 Saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox" with version "1.19-windows"
00:00:12.572765 Finished saving settings file "D:\Data\slots\0\boinc_4fbb7b6178a94f4f\boinc_4fbb7b6178a94f4f.vbox"
00:00:12.771874 Saving settings file "C:\Users\matth\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:12.777204 Finished saving settings file "C:\Users\matth\.VirtualBox\VirtualBox.xml"
00:00:12.777446 Saving settings file "C:\Users\matth\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:12.782369 Finished saving settings file "C:\Users\matth\.VirtualBox\VirtualBox.xml"
00:00:12.783767 DeleteVM Saving settings file "C:\Users\matth\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:12.788218 DeleteVM Finished saving settings file "C:\Users\matth\.VirtualBox\VirtualBox.xml"
00:00:17.800180 main VirtualBox: object deletion starts
00:00:17.800278 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={7d510820-a678-4730-a862-818dcd3fbed0} aComponent={MediumWrap} aText={Medium 'D:\VirtualMachines\sharedNTFSdrives\NTFSw2k_01.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:17.801206 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={7d510820-a678-4730-a862-818dcd3fbed0} aComponent={MediumWrap} aText={Medium 'D:\VirtualMachines\W764_Cuprosoft\W764_Cuprosoft.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:17.803836 main HostDnsMonitor: shutting down ...
00:00:17.803919 main HostDnsMonitor: shut down
00:00:17.806228 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={2ce10519-3c09-45d8-a12d-e887786146b7} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.807039 main VirtualBox: object deleted
VM Execution Log:
VM Startup Log:
VM Trace Log:
uart3="off"
uart4="off"
lpt1="off"
lpt2="off"
audio="default"
audio_out="off"
audio_in="off"
clipboard="disabled"
clipboard_file_transfers="off"
draganddrop="disabled"
vrde="off"
usb="off"
ehci="off"
xhci="off"
recording_started="off"
recording_enabled="off"
recording_screens=1
rec_screen0
rec_screen_enabled="on"
rec_screen_id=0
rec_screen_video_enabled="on"
rec_screen_audio_enabled="off"
rec_screen_dest="File"
rec_screen_dest_filename="D:\\Data\\slots\\0\\boinc_4fbb7b6178a94f4f\\boinc_4fbb7b6178a94f4f-screen0.webm"
rec_screen_opts="ac_profile=med"
rec_screen_video_res_xy="1024x768"
rec_screen_video_rate_kbps=512
rec_screen_video_fps=25
description="5LBMDmzQY38nsSi4ap6QjLDmwznN0nGgGQJmNLGKDmM02KDmRpNv0n_0"
GuestMemoryBalloon=0
2026-01-23 19:40:34 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on
Exit Code: 0
Output:
2026-01-23 19:40:34 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --cable-connected1 on
Exit Code: 0
Output:
2026-01-23 19:40:34 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --usb off
Exit Code: 0
Output:
2026-01-23 19:40:34 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --uart1 off --uart2 off
Exit Code: 0
Output:
2026-01-23 19:40:35 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --lpt1 off --lpt2 off
Exit Code: 0
Output:
2026-01-23 19:40:35 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --audio-enabled off
Exit Code: 0
Output:
2026-01-23 19:40:35 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --clipboard disabled
Exit Code: 0
Output:
2026-01-23 19:40:35 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --draganddrop disabled
Exit Code: 0
Output:
2026-01-23 19:40:36 (14836):
Command: VBoxManage -q storagectl "boinc_4fbb7b6178a94f4f" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:
2026-01-23 19:40:36 (14836):
Command: VBoxManage -q showhdinfo "D:\Data/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
UUID: 3e56213b-898f-4e83-899f-8eb541d45260
Parent UUID: base
State: created
Type: multiattach
Location: D:\Data\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20480 MBytes
Size on disk: 4204 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
2026-01-23 19:40:36 (14836):
Command: VBoxManage -q storageattach "boinc_4fbb7b6178a94f4f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "D:\Data/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'D:\Data\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp
2026-01-23 19:40:37 (14836):
Command: VBoxManage -q showhdinfo "D:\Data/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
UUID: 3e56213b-898f-4e83-899f-8eb541d45260
Parent UUID: base
State: created
Type: multiattach
Location: D:\Data\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20480 MBytes
Size on disk: 4204 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
2026-01-23 19:40:37 (14836):
Command: VBoxManage -q closemedium disk "D:\Data\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
2026-01-23 19:40:37 (14836):
Command: VBoxManage -q showhdinfo "D:\Data/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
UUID: 3e56213b-898f-4e83-899f-8eb541d45260
Parent UUID: base
State: created
Type: normal (base)
Location: D:\Data\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20480 MBytes
Size on disk: 4204 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
2026-01-23 19:40:37 (14836):
Command: VBoxManage -q storageattach "boinc_4fbb7b6178a94f4f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "D:\Data/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
2026-01-23 19:40:38 (14836):
Command: VBoxManage -q storageattach "boinc_4fbb7b6178a94f4f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none
Exit Code: 0
Output:
2026-01-23 19:40:38 (14836):
Command: VBoxManage -q storageattach "boinc_4fbb7b6178a94f4f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "D:\Data/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi"
Exit Code: 0
Output:
2026-01-23 19:40:38 (14836):
Command: VBoxManage -q storageattach "boinc_4fbb7b6178a94f4f" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\APPS\VBOX/VBoxGuestAdditions.iso"
Exit Code: 0
Output:
2026-01-23 19:40:38 (14836):
Command: VBoxManage -q bandwidthctl "boinc_4fbb7b6178a94f4f" add "boinc_4fbb7b6178a94f4f_net" --type network --limit 1024G
Exit Code: 0
Output:
2026-01-23 19:40:39 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --natpf1 ",tcp,127.0.0.1,11507,,80"
Exit Code: 0
Output:
2026-01-23 19:40:39 (14836):
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0: Oracle VM VirtualBox Extension Pack
Version: 5.2.16
Revision: 123759
Edition:
Description: USB 2.0 and USB 3.0 Host Controller, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe.
VRDE Module: VBoxVRDP
Crypto Module:
Usable: false
Why unusable: VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='Helper version mismatch - expected 0x10002 got 0x50000'
2026-01-23 19:40:39 (14836):
Command: VBoxManage -q modifyvm "boinc_4fbb7b6178a94f4f" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 11523 --vrde-property "Security/Method=RDP"
Exit Code: 0
Output:
2026-01-23 19:40:40 (14836):
Command: VBoxManage -q sharedfolder add "boinc_4fbb7b6178a94f4f" --name "shared" --hostpath "D:\Data\slots\0/shared"
Exit Code: 0
Output:
2026-01-23 19:40:41 (14836):
Command: VBoxManage -q startvm "boinc_4fbb7b6178a94f4f" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_4fbb7b6178a94f4f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'D:\Data\slots\0\boinc_4fbb7b6178a94f4f\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_4fbb7b6178a94f4f" to power on...
2026-01-23 19:40:41 (14836):
Command: VBoxManage -q snapshot "boinc_4fbb7b6178a94f4f" list
Exit Code: -108
Output:
This machine does not have any snapshots
2026-01-23 19:40:42 (14836):
Command: VBoxManage -q bandwidthctl "boinc_4fbb7b6178a94f4f" remove "boinc_4fbb7b6178a94f4f_net"
Exit Code: 0
Output:
2026-01-23 19:40:42 (14836):
Command: VBoxManage -q unregistervm "boinc_4fbb7b6178a94f4f" --delete
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%
2026-01-23 19:40:47 (14836): called boinc_finish(1)
</stderr_txt>
]]>
©2026 CERN