Name | oDHMDmvSnT8n9Rq4apOajLDm4fhM0noT9bVof3QYDmUHZMDmiAQmXo_1 |
Workunit | 236451552 |
Created | 17 Oct 2025, 3:09:22 UTC |
Sent | 17 Oct 2025, 6:01:16 UTC |
Report deadline | 25 Oct 2025, 6:01:16 UTC |
Received | 17 Oct 2025, 7:40:30 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10458127 |
Run time | 25 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 12.84 GFLOPS |
Application version | ATLAS Simulation v3.03 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 12.22 MB |
Peak swap size | 2.38 MB |
Peak disk usage | 217.68 MB |
<core_client_version>8.2.4</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-10-16 23:39:34 (16328): vboxwrapper version 26210 2025-10-16 23:39:34 (16328): BOINC client version: 8.2.4 2025-10-16 23:39:36 (16328): Detected: VirtualBox VboxManage Interface (Version: 7.1.10) 2025-10-16 23:39:36 (16328): Successfully copied 'init_data.xml' to the shared directory. 2025-10-16 23:39:36 (16328): Create VM. (boinc_b0bd476b9d96c8c9, slot#3) 2025-10-16 23:39:37 (16328): Setting Memory Size for VM. (4300MB) 2025-10-16 23:39:37 (16328): Setting CPU Count for VM. (3) 2025-10-16 23:39:38 (16328): Setting Chipset Options for VM. 2025-10-16 23:39:38 (16328): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB) 2025-10-16 23:39:38 (16328): Setting Boot Options for VM. 2025-10-16 23:39:39 (16328): Setting Network Configuration for NAT. (Driver: virtio) 2025-10-16 23:39:39 (16328): Enabling VM Network Access. 2025-10-16 23:39:39 (16328): Disabling USB Support for VM. 2025-10-16 23:39:40 (16328): Disabling COM Port Support for VM. 2025-10-16 23:39:40 (16328): Disabling LPT Port Support for VM. 2025-10-16 23:39:40 (16328): Disabling Audio Support for VM. 2025-10-16 23:39:40 (16328): Disabling Clipboard Support for VM. 2025-10-16 23:39:41 (16328): Disabling Drag and Drop Support for VM. 2025-10-16 23:39:41 (16328): Adding storage controller(s) to VM. 2025-10-16 23:39:41 (16328): Adding virtual disk drive to VM. (ATLAS_vbox_3.03_image.vdi) 2025-10-16 23:39:43 (16328): Adding VirtualBox Guest Additions to VM. 2025-10-16 23:39:44 (16328): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-10-16 23:39:44 (16328): forwarding host port 61896 to guest port 80 2025-10-16 23:39:44 (16328): Enabling remote desktop for VM. 2025-10-16 23:39:45 (16328): Enabling shared directory for VM. 2025-10-16 23:39:46 (16328): Starting VM using VBoxManage interface. (boinc_b0bd476b9d96c8c9, slot#3) 2025-10-16 23:39:52 (16328): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_b0bd476b9d96c8c9" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_b0bd476b9d96c8c9" to power on... 2025-10-16 23:39:52 (16328): VM failed to start. 2025-10-16 23:39:52 (16328): Could not start 2025-10-16 23:39:52 (16328): ERROR: VM failed to start 2025-10-16 23:39:52 (16328): Powering off VM. 2025-10-16 23:39:52 (16328): Deregistering VM. (boinc_b0bd476b9d96c8c9, slot#3) 2025-10-16 23:39:52 (16328): Removing network bandwidth throttle group from VM. 2025-10-16 23:39:52 (16328): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.490467 Finished saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" 00:00:08.490975 Saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" with version "1.19-windows" 00:00:08.518373 Finished saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" 00:00:08.749236 Platform architecture set to 'x86' 00:00:08.751558 Saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" with version "1.19-windows" 00:00:08.776979 Finished saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" 00:00:09.017826 Platform architecture set to 'x86' 00:00:09.021664 Saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" with version "1.19-windows" 00:00:09.043024 Finished saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" 00:00:09.557663 Platform architecture set to 'x86' 00:00:09.560704 VRDE: Generating certificate files 'E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\VRDEAutoGeneratedCert.pem' and 'E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\VRDEAutoGeneratedPrivateKey.pem'... 00:00:09.664281 Saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" with version "1.19-windows" 00:00:09.806069 Finished saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" 00:00:10.089669 Platform architecture set to 'x86' 00:00:10.092668 Saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" with version "1.19-windows" 00:00:10.127543 Finished saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" 00:00:10.340566 Platform architecture set to 'x86' 00:00:10.343287 ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0 00:00:10.353169 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.353354 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.540871 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={bea3ef5c-de2f-4b74-aa3a-15d6249371a0} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0 00:00:10.542396 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.568822 USBPROXY usbLibGetDevices: Starting USB device enumeration 00:00:10.585242 USBPROXY Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&575da04&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 3 00:00:10.608338 USBPROXY usbLibDevGetHubPortDevices: No DriverKey on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:10.608373 USBPROXY usbLibDevCfgDrGet: IOCTL_USB_GET_DESCRIPTOR_FROM_NODE_CONNECTION #1 failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:10.608645 USBPROXY usbLibGetDevices: Found 6 USB devices, 0 captured 00:00:10.886808 Launched VM: 3228611440 pid: 3436 (0xd6c) frontend: headless name: boinc_b0bd476b9d96c8c9 00:00:13.482646 USBPROXY usbLibGetDevices: Starting USB device enumeration 00:00:13.499168 USBPROXY Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&575da04&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 3 00:00:13.522282 USBPROXY usbLibDevGetHubPortDevices: No DriverKey on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:13.522350 USBPROXY usbLibDevCfgDrGet: IOCTL_USB_GET_DESCRIPTOR_FROM_NODE_CONNECTION #1 failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:13.522655 USBPROXY usbLibGetDevices: Found 6 USB devices, 0 captured 00:00:15.590448 Platform architecture set to 'x86' 00:00:16.182171 USBPROXY usbLibGetDevices: Starting USB device enumeration 00:00:16.198638 USBPROXY Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&575da04&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 3 00:00:16.221348 USBPROXY usbLibDevGetHubPortDevices: No DriverKey on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:16.221388 USBPROXY usbLibDevCfgDrGet: IOCTL_USB_GET_DESCRIPTOR_FROM_NODE_CONNECTION #1 failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:16.221679 USBPROXY usbLibGetDevices: Found 6 USB devices, 0 captured 00:00:17.103438 Saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" with version "1.19-windows" 00:00:17.160066 Finished saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" 00:00:17.268798 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:17.371746 Platform architecture set to 'x86' 00:00:17.373883 Saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" with version "1.19-windows" 00:00:17.412618 Finished saving settings file "E:\ProgramData1\BOINC\slots\3\boinc_b0bd476b9d96c8c9\boinc_b0bd476b9d96c8c9.vbox" 00:00:17.631451 Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.634564 Finished saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" 00:00:17.634642 Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.637513 Finished saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" 00:00:17.638784 DeleteVM Saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.642595 DeleteVM Finished saving settings file "C:\Users\Allan\.VirtualBox\VirtualBox.xml" 00:00:22.420972 USBPROXY usbLibGetDevices: Starting USB device enumeration 00:00:22.437500 USBPROXY Getting USB descriptor (id 0) failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&575da04&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 3 00:00:22.459819 USBPROXY usbLibDevGetHubPortDevices: No DriverKey on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:22.459853 USBPROXY usbLibDevCfgDrGet: IOCTL_USB_GET_DESCRIPTOR_FROM_NODE_CONNECTION #1 failed (dwErr=31) on hub USB#VID_8087&PID_0024#5&c42fd0f&0&1#{f18a0e88-c30c-11d0-8815-00a0c906bed8} port 5 00:00:22.460156 USBPROXY usbLibGetDevices: Found 6 USB devices, 0 captured 00:00:22.664765 main VirtualBox: object deletion starts 00:00:22.667094 main HostDnsMonitor: shutting down ... 00:00:22.667152 main HostDnsMonitor: shut down 00:00:22.670446 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:22.671019 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: clipboard="disabled" clipboard_file_transfers="off" draganddrop="disabled" vrde="off" usb="off" ehci="off" xhci="off" recording_started="off" recording_enabled="off" recording_screens=1 rec_screen0 rec_screen_enabled="on" rec_screen_id=0 rec_screen_video_enabled="on" rec_screen_audio_enabled="off" rec_screen_dest="File" rec_screen_dest_filename="E:\\ProgramData1\\BOINC\\slots\\3\\boinc_b0bd476b9d96c8c9\\boinc_b0bd476b9d96c8c9-screen0.webm" rec_screen_opts="vc_enabled=true,ac_enabled=false,ac_profile=med" rec_screen_video_res_xy="1024x768" rec_screen_video_rate_kbps=512 rec_screen_video_fps=25 description="oDHMDmvSnT8n9Rq4apOajLDm4fhM0noT9bVof3QYDmUHZMDmiAQmXo_1" GuestMemoryBalloon=0 2025-10-16 23:39:39 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on Exit Code: 0 Output: 2025-10-16 23:39:39 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --cable-connected1 on Exit Code: 0 Output: 2025-10-16 23:39:40 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --usb off Exit Code: 0 Output: 2025-10-16 23:39:40 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --uart1 off --uart2 off Exit Code: 0 Output: 2025-10-16 23:39:40 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-10-16 23:39:40 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --audio-enabled off Exit Code: 0 Output: 2025-10-16 23:39:41 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --clipboard disabled Exit Code: 0 Output: 2025-10-16 23:39:41 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --draganddrop disabled Exit Code: 0 Output: 2025-10-16 23:39:41 (16328): Command: VBoxManage -q storagectl "boinc_b0bd476b9d96c8c9" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-10-16 23:39:41 (16328): Command: VBoxManage -q showhdinfo "E:\ProgramData1\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: UUID: 3e56213b-898f-4e83-899f-8eb541d45260 Parent UUID: base State: created Type: multiattach Location: E:\ProgramData1\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-10-16 23:39:42 (16328): Command: VBoxManage -q storageattach "boinc_b0bd476b9d96c8c9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\ProgramData1\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'E:\ProgramData1\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp 2025-10-16 23:39:42 (16328): Command: VBoxManage -q showhdinfo "E:\ProgramData1\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: UUID: 3e56213b-898f-4e83-899f-8eb541d45260 Parent UUID: base State: created Type: multiattach Location: E:\ProgramData1\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-10-16 23:39:42 (16328): Command: VBoxManage -q closemedium disk "E:\ProgramData1\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: 2025-10-16 23:39:43 (16328): Command: VBoxManage -q showhdinfo "E:\ProgramData1\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: UUID: 3e56213b-898f-4e83-899f-8eb541d45260 Parent UUID: base State: created Type: normal (base) Location: E:\ProgramData1\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-10-16 23:39:43 (16328): Command: VBoxManage -q storageattach "boinc_b0bd476b9d96c8c9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "E:\ProgramData1\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: 2025-10-16 23:39:43 (16328): Command: VBoxManage -q storageattach "boinc_b0bd476b9d96c8c9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-10-16 23:39:43 (16328): Command: VBoxManage -q storageattach "boinc_b0bd476b9d96c8c9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\ProgramData1\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: 2025-10-16 23:39:44 (16328): Command: VBoxManage -q storageattach "boinc_b0bd476b9d96c8c9" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-10-16 23:39:44 (16328): Command: VBoxManage -q bandwidthctl "boinc_b0bd476b9d96c8c9" add "boinc_b0bd476b9d96c8c9_net" --type network --limit 1024G Exit Code: 0 Output: 2025-10-16 23:39:44 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --natpf1 ",tcp,127.0.0.1,61896,,80" Exit Code: 0 Output: 2025-10-16 23:39:44 (16328): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VirtualBox Extension Pack Version: 7.1.8 Revision: 168469 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: true Why unusable: 2025-10-16 23:39:45 (16328): Command: VBoxManage -q modifyvm "boinc_b0bd476b9d96c8c9" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 61898 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-10-16 23:39:45 (16328): Command: VBoxManage -q sharedfolder add "boinc_b0bd476b9d96c8c9" --name "shared" --hostpath "E:\ProgramData1\BOINC\slots\3/shared" Exit Code: 0 Output: 2025-10-16 23:39:52 (16328): Command: VBoxManage -q startvm "boinc_b0bd476b9d96c8c9" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_b0bd476b9d96c8c9" to power on... 2025-10-16 23:39:52 (16328): Command: VBoxManage -q snapshot "boinc_b0bd476b9d96c8c9" list Exit Code: -108 Output: This machine does not have any snapshots 2025-10-16 23:39:52 (16328): Command: VBoxManage -q bandwidthctl "boinc_b0bd476b9d96c8c9" remove "boinc_b0bd476b9d96c8c9_net" Exit Code: 0 Output: 2025-10-16 23:39:53 (16328): Command: VBoxManage -q unregistervm "boinc_b0bd476b9d96c8c9" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-10-16 23:39:58 (16328): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN