Name | h4xNDmDpXR8n9Rq4apOajLDm4fhM0noT9bVof3QYDmxSQMDm7vPVxm_1 |
Workunit | 235845461 |
Created | 10 Oct 2025, 22:16:02 UTC |
Sent | 11 Oct 2025, 0:56:11 UTC |
Report deadline | 19 Oct 2025, 0:56:11 UTC |
Received | 11 Oct 2025, 2:17:56 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10489461 |
Run time | 9 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 26.42 GFLOPS |
Application version | ATLAS Simulation v3.03 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 10.51 MB |
Peak swap size | 1.79 MB |
Peak disk usage | 210.48 MB |
<core_client_version>8.2.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-10-10 18:16:54 (2620): vboxwrapper version 26210 2025-10-10 18:16:54 (2620): BOINC client version: 8.2.4 2025-10-10 18:16:55 (2620): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-10-10 18:16:56 (2620): Successfully copied 'init_data.xml' to the shared directory. 2025-10-10 18:16:56 (2620): Create VM. (boinc_ced46e5b1af7bf67, slot#38) 2025-10-10 18:16:56 (2620): Setting Memory Size for VM. (4800MB) 2025-10-10 18:16:57 (2620): Setting CPU Count for VM. (8) 2025-10-10 18:16:57 (2620): Setting Chipset Options for VM. 2025-10-10 18:16:57 (2620): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB) 2025-10-10 18:16:58 (2620): Setting Boot Options for VM. 2025-10-10 18:16:58 (2620): Setting Network Configuration for NAT. (Driver: virtio) 2025-10-10 18:16:58 (2620): Enabling VM Network Access. 2025-10-10 18:16:59 (2620): Disabling USB Support for VM. 2025-10-10 18:16:59 (2620): Disabling COM Port Support for VM. 2025-10-10 18:16:59 (2620): Disabling LPT Port Support for VM. 2025-10-10 18:16:59 (2620): Disabling Audio Support for VM. 2025-10-10 18:17:00 (2620): Disabling Clipboard Support for VM. 2025-10-10 18:17:00 (2620): Disabling Drag and Drop Support for VM. 2025-10-10 18:17:00 (2620): Adding storage controller(s) to VM. 2025-10-10 18:17:00 (2620): Adding virtual disk drive to VM. (ATLAS_vbox_3.03_image.vdi) 2025-10-10 18:17:02 (2620): Adding VirtualBox Guest Additions to VM. 2025-10-10 18:17:03 (2620): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-10-10 18:17:03 (2620): forwarding host port 50118 to guest port 80 2025-10-10 18:17:03 (2620): Enabling remote desktop for VM. 2025-10-10 18:17:04 (2620): Enabling shared directory for VM. 2025-10-10 18:17:05 (2620): Starting VM using VBoxManage interface. (boinc_ced46e5b1af7bf67, slot#38) 2025-10-10 18:17:05 (2620): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_ced46e5b1af7bf67" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_ced46e5b1af7bf67' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\38\boinc_ced46e5b1af7bf67\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_ced46e5b1af7bf67" to power on... 2025-10-10 18:17:05 (2620): VM failed to start. 2025-10-10 18:17:05 (2620): Could not start 2025-10-10 18:17:05 (2620): ERROR: VM failed to start 2025-10-10 18:17:05 (2620): Powering off VM. 2025-10-10 18:17:05 (2620): Deregistering VM. (boinc_ced46e5b1af7bf67, slot#38) 2025-10-10 18:17:05 (2620): Removing network bandwidth throttle group from VM. 2025-10-10 18:17:07 (2620): Attempts: 2 2025-10-10 18:17:07 (2620): Removing VM from VirtualBox. Hypervisor System Log: 04:20:43.756697 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:44.248053 Saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" with version "1.19-windows" 04:20:44.259948 Finished saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" 04:20:44.275922 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:44.305489 Saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 04:20:44.313829 Finished saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" 04:20:44.314511 Saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" with version "1.19-windows" 04:20:44.325395 Finished saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" 04:20:44.327184 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" with version "1.19-windows" 04:20:44.327904 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {17c9a64c-b603-43e5-8fc1-0f17da6ca1a2}}, preserve=false aResultDetail=0 04:20:44.340452 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" 04:20:44.342772 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {17c9a64c-b603-43e5-8fc1-0f17da6ca1a2}}, preserve=false aResultDetail=0 04:20:44.351246 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:44.512929 Saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" with version "1.19-windows" 04:20:44.525232 Finished saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" 04:20:44.539810 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:44.759876 ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0 04:20:44.771079 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 04:20:44.771221 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 04:20:44.775247 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:44.944181 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 04:20:44.959328 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:45.284341 Launched VM: 3354653824 pid: 22424 (0x5798) frontend: headless name: boinc_40eceb0f6d7687f5 04:20:45.302619 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:45.733582 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_40eceb0f6d7687f5' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 04:20:45.734324 Watcher Reaper: Pid 22424 (0x5798) exited normally: 1 (0x1) 04:20:45.762734 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:45.844156 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 04:20:45.855277 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:45.943747 Saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" with version "1.19-windows" 04:20:45.957671 Finished saving settings file "C:\ProgramData\BOINC\slots\39\boinc_40eceb0f6d7687f5\boinc_40eceb0f6d7687f5.vbox" 04:20:45.974862 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is PoweredOff)}, preserve=false aResultDetail=0 04:20:46.209758 Saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 04:20:46.216093 Finished saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" 04:20:46.216596 Saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 04:20:46.222795 Finished saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" 04:20:46.224403 DeleteVM Saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 04:20:46.230540 DeleteVM Finished saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" 04:20:46.231923 Saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 04:20:46.238128 Finished saving settings file "C:\Users\Dad\.VirtualBox\VirtualBox.xml" 04:20:46.253807 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {51b3ae9c-0d85-4fd2-b6e1-2e7cce258b90}}, preserve=false aResultDetail=0 04:20:46.269386 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {51b3ae9c-0d85-4fd2-b6e1-2e7cce258b90}}, preserve=false aResultDetail=0 04:20:46.295398 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The machine is not mutable (state is Running)}, preserve=false aResultDetail=0 VM Execution Log: VM Startup Log: VM Trace Log: io="default" audio_out="off" audio_in="off" clipboard="disabled" draganddrop="disabled" vrde="off" usb="off" ehci="off" xhci="off" recording_enabled="off" recording_screens=1 rec_screen0 rec_screen_enabled="on" rec_screen_id=0 rec_screen_video_enabled="on" rec_screen_audio_enabled="off" rec_screen_dest="File" rec_screen_dest_filename="C:\\ProgramData\\BOINC\\slots\\38\\boinc_ced46e5b1af7bf67\\boinc_ced46e5b1af7bf67-screen0.webm" rec_screen_opts="vc_enabled=true,ac_enabled=false,ac_profile=med" rec_screen_video_res_xy="1024x768" rec_screen_video_rate_kbps=512 rec_screen_video_fps=25 description="h4xNDmDpXR8n9Rq4apOajLDm4fhM0noT9bVof3QYDmxSQMDm7vPVxm_1" GuestMemoryBalloon=0 2025-10-10 18:16:58 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on Exit Code: 0 Output: 2025-10-10 18:16:59 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --cable-connected1 on Exit Code: 0 Output: 2025-10-10 18:16:59 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --usb off Exit Code: 0 Output: 2025-10-10 18:16:59 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --uart1 off --uart2 off Exit Code: 0 Output: 2025-10-10 18:16:59 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-10-10 18:17:00 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --audio-enabled off Exit Code: 0 Output: 2025-10-10 18:17:00 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --clipboard disabled Exit Code: 0 Output: 2025-10-10 18:17:00 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --draganddrop disabled Exit Code: 0 Output: 2025-10-10 18:17:00 (2620): Command: VBoxManage -q storagectl "boinc_ced46e5b1af7bf67" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-10-10 18:17:01 (2620): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: UUID: 3e56213b-898f-4e83-899f-8eb541d45260 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-10-10 18:17:01 (2620): Command: VBoxManage -q storageattach "boinc_ced46e5b1af7bf67" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-10-10 18:17:01 (2620): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: UUID: 3e56213b-898f-4e83-899f-8eb541d45260 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-10-10 18:17:01 (2620): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: 2025-10-10 18:17:02 (2620): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: UUID: 3e56213b-898f-4e83-899f-8eb541d45260 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.03_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-10-10 18:17:02 (2620): Command: VBoxManage -q storageattach "boinc_ced46e5b1af7bf67" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: 2025-10-10 18:17:02 (2620): Command: VBoxManage -q storageattach "boinc_ced46e5b1af7bf67" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-10-10 18:17:02 (2620): Command: VBoxManage -q storageattach "boinc_ced46e5b1af7bf67" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.03_image.vdi" Exit Code: 0 Output: 2025-10-10 18:17:03 (2620): Command: VBoxManage -q storageattach "boinc_ced46e5b1af7bf67" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-10-10 18:17:03 (2620): Command: VBoxManage -q bandwidthctl "boinc_ced46e5b1af7bf67" add "boinc_ced46e5b1af7bf67_net" --type network --limit 1024G Exit Code: 0 Output: 2025-10-10 18:17:03 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --natpf1 ",tcp,127.0.0.1,50118,,80" Exit Code: 0 Output: 2025-10-10 18:17:03 (2620): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 7.0.6 Revision: 155176 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: true Why unusable: 2025-10-10 18:17:04 (2620): Command: VBoxManage -q modifyvm "boinc_ced46e5b1af7bf67" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 50119 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-10-10 18:17:04 (2620): Command: VBoxManage -q sharedfolder add "boinc_ced46e5b1af7bf67" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\38/shared" Exit Code: 0 Output: 2025-10-10 18:17:05 (2620): Command: VBoxManage -q startvm "boinc_ced46e5b1af7bf67" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_ced46e5b1af7bf67' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\38\boinc_ced46e5b1af7bf67\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_ced46e5b1af7bf67" to power on... 2025-10-10 18:17:05 (2620): Command: VBoxManage -q snapshot "boinc_ced46e5b1af7bf67" list Exit Code: -108 Output: This machine does not have any snapshots 2025-10-10 18:17:06 (2620): Command: VBoxManage -q bandwidthctl "boinc_ced46e5b1af7bf67" remove "boinc_ced46e5b1af7bf67_net" Exit Code: 0 Output: 2025-10-10 18:17:07 (2620): Command: VBoxManage -q unregistervm "boinc_ced46e5b1af7bf67" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-10-10 18:17:17 (2620): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN