Name | Theory_2922-4803299-113_2 |
Workunit | 233764725 |
Created | 26 Jul 2025, 20:27:29 UTC |
Sent | 27 Jul 2025, 15:59:25 UTC |
Report deadline | 7 Aug 2025, 15:59:25 UTC |
Received | 27 Jul 2025, 16:01:38 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10851140 |
Run time | 20 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.75 GFLOPS |
Application version | Theory Simulation v300.98 (vbox64_theory) windows_x86_64 |
Peak working set size | 7.17 MB |
Peak swap size | 1.82 MB |
Peak disk usage | 1.47 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-07-27 08:59:23 (24676): vboxwrapper version 26210 2025-07-27 08:59:23 (24676): BOINC client version: 8.0.2 2025-07-27 08:59:23 (24676): Detected: VirtualBox VboxManage Interface (Version: 7.1.12) 2025-07-27 08:59:24 (24676): Detected: Heartbeat check (file: 'heartbeat' every 1800.000000 seconds) 2025-07-27 08:59:24 (24676): Successfully copied 'init_data.xml' to the shared directory. 2025-07-27 08:59:24 (24676): Successfully copied 'input' to the shared directory. 2025-07-27 08:59:24 (24676): Create VM. (boinc_ebc920a826ebacbb, slot#1) 2025-07-27 08:59:25 (24676): Setting Memory Size for VM. (630MB) 2025-07-27 08:59:25 (24676): Setting CPU Count for VM. (1) 2025-07-27 08:59:25 (24676): Setting Chipset Options for VM. 2025-07-27 08:59:25 (24676): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB) 2025-07-27 08:59:26 (24676): Setting Boot Options for VM. 2025-07-27 08:59:26 (24676): Setting Network Configuration for NAT. (Driver: virtio) 2025-07-27 08:59:26 (24676): Enabling VM Network Access. 2025-07-27 08:59:27 (24676): Disabling USB Support for VM. 2025-07-27 08:59:27 (24676): Disabling COM Port Support for VM. 2025-07-27 08:59:27 (24676): Disabling LPT Port Support for VM. 2025-07-27 08:59:28 (24676): Disabling Audio Support for VM. 2025-07-27 08:59:28 (24676): Disabling Clipboard Support for VM. 2025-07-27 08:59:28 (24676): Disabling Drag and Drop Support for VM. 2025-07-27 08:59:29 (24676): Adding storage controller(s) to VM. 2025-07-27 08:59:29 (24676): Adding virtual disk drive to VM. (Theory_2025_07_03_prod.vdi) 2025-07-27 08:59:31 (24676): Adding VirtualBox Guest Additions to VM. 2025-07-27 08:59:31 (24676): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-07-27 08:59:31 (24676): forwarding host port 50120 to guest port 80 2025-07-27 08:59:32 (24676): Enabling remote desktop for VM. 2025-07-27 08:59:32 (24676): Enabling shared directory for VM. 2025-07-27 08:59:33 (24676): Starting VM using VBoxManage interface. (boinc_ebc920a826ebacbb, slot#1) 2025-07-27 08:59:36 (24676): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_ebc920a826ebacbb" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_ebc920a826ebacbb" to power on... 2025-07-27 08:59:36 (24676): VM failed to start. 2025-07-27 08:59:36 (24676): Could not start 2025-07-27 08:59:36 (24676): ERROR: VM failed to start 2025-07-27 08:59:36 (24676): Powering off VM. 2025-07-27 08:59:36 (24676): Deregistering VM. (boinc_ebc920a826ebacbb, slot#1) 2025-07-27 08:59:36 (24676): Removing network bandwidth throttle group from VM. 2025-07-27 08:59:36 (24676): Removing VM from VirtualBox. Hypervisor System Log: 00:00:14.079273 Platform architecture set to 'x86' 00:00:14.080293 VRDE: Generating certificate files 'E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\VRDEAutoGeneratedCert.pem' and 'E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\VRDEAutoGeneratedPrivateKey.pem'... 00:00:14.130738 Saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" with version "1.19-windows" 00:00:14.214251 Finished saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" 00:00:14.335138 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.335864 Platform architecture set to 'x86' 00:00:14.336718 Saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" with version "1.19-windows" 00:00:14.364362 Finished saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" 00:00:14.382675 Platform architecture set to 'x86' 00:00:14.591428 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.592137 Platform architecture set to 'x86' 00:00:14.593259 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:14.596625 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.596675 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.600728 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={bea3ef5c-de2f-4b74-aa3a-15d6249371a0} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0 00:00:14.601269 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.845639 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.851185 Launched VM: 1794300928 pid: 23328 (0x5b20) frontend: headless name: boinc_ebc920a826ebacbb 00:00:15.423309 Saving settings file "E:\ProgramData\BOINC\slots\0\boinc_6ca3ab30420231d6\boinc_6ca3ab30420231d6.vbox" with version "1.19-windows" 00:00:15.508799 Finished saving settings file "E:\ProgramData\BOINC\slots\0\boinc_6ca3ab30420231d6\boinc_6ca3ab30420231d6.vbox" 00:00:15.551051 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:15.552188 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.587680 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:15.855966 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:15.856367 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:15.856434 Saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.859231 Finished saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" 00:00:15.859308 Saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.861934 Finished saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" 00:00:15.862863 DeleteVM Saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.865690 DeleteVM Finished saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" 00:00:17.560238 Platform architecture set to 'x86' 00:00:18.234446 Saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" with version "1.19-windows" 00:00:18.257097 Finished saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" 00:00:18.298444 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:18.299568 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:18.335124 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:18.335872 Platform architecture set to 'x86' 00:00:18.336812 Saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" with version "1.19-windows" 00:00:18.357034 Finished saving settings file "E:\ProgramData\BOINC\slots\1\boinc_ebc920a826ebacbb\boinc_ebc920a826ebacbb.vbox" 00:00:18.595611 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:18.595869 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:18.595941 Saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:18.599304 Finished saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" 00:00:18.599377 Saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:18.602370 Finished saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" 00:00:18.603034 DeleteVM Saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:18.605695 DeleteVM Finished saving settings file "C:\Users\doche\.VirtualBox\VirtualBox.xml" 00:00:23.616356 main VirtualBox: object deletion starts 00:00:23.617311 main HostDnsMonitor: shutting down ... 00:00:23.617361 main HostDnsMonitor: shut down 00:00:23.618647 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:23.618999 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: ci="off" xhci="off" recording_started="off" recording_enabled="off" recording_screens=1 rec_screen0 rec_screen_enabled="on" rec_screen_id=0 rec_screen_video_enabled="on" rec_screen_audio_enabled="off" rec_screen_dest="File" rec_screen_dest_filename="E:\\ProgramData\\BOINC\\slots\\1\\boinc_ebc920a826ebacbb\\boinc_ebc920a826ebacbb-screen0.webm" rec_screen_opts="vc_enabled=true,ac_enabled=false,ac_profile=med" rec_screen_video_res_xy="1024x768" rec_screen_video_rate_kbps=512 rec_screen_video_fps=25 description="Theory_2922-4803299-113_2" GuestMemoryBalloon=0 2025-07-27 08:59:26 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on Exit Code: 0 Output: 2025-07-27 08:59:27 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --cable-connected1 on Exit Code: 0 Output: 2025-07-27 08:59:27 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --usb off Exit Code: 0 Output: 2025-07-27 08:59:27 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --uart1 off --uart2 off Exit Code: 0 Output: 2025-07-27 08:59:28 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-07-27 08:59:28 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --audio-enabled off Exit Code: 0 Output: 2025-07-27 08:59:28 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --clipboard disabled Exit Code: 0 Output: 2025-07-27 08:59:29 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --draganddrop disabled Exit Code: 0 Output: 2025-07-27 08:59:29 (24676): Command: VBoxManage -q storagectl "boinc_ebc920a826ebacbb" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-07-27 08:59:29 (24676): Command: VBoxManage -q showhdinfo "E:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" Exit Code: 0 Output: UUID: 93ef7340-8636-46d8-8751-a7cb0c80413d Parent UUID: base State: created Type: multiattach Location: E:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 10240 MBytes Size on disk: 2847 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-07-27 08:59:29 (24676): Command: VBoxManage -q storageattach "boinc_ebc920a826ebacbb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'E:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp 2025-07-27 08:59:30 (24676): Command: VBoxManage -q showhdinfo "E:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" Exit Code: 0 Output: UUID: 93ef7340-8636-46d8-8751-a7cb0c80413d Parent UUID: base State: created Type: multiattach Location: E:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 10240 MBytes Size on disk: 2847 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-07-27 08:59:30 (24676): Command: VBoxManage -q closemedium disk "E:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi" Exit Code: 0 Output: 2025-07-27 08:59:30 (24676): Command: VBoxManage -q showhdinfo "E:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" Exit Code: 0 Output: UUID: 93ef7340-8636-46d8-8751-a7cb0c80413d Parent UUID: base State: created Type: normal (base) Location: E:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 10240 MBytes Size on disk: 2847 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-07-27 08:59:30 (24676): Command: VBoxManage -q storageattach "boinc_ebc920a826ebacbb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "E:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" Exit Code: 0 Output: 2025-07-27 08:59:31 (24676): Command: VBoxManage -q storageattach "boinc_ebc920a826ebacbb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-07-27 08:59:31 (24676): Command: VBoxManage -q storageattach "boinc_ebc920a826ebacbb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" Exit Code: 0 Output: 2025-07-27 08:59:31 (24676): Command: VBoxManage -q storageattach "boinc_ebc920a826ebacbb" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-07-27 08:59:31 (24676): Command: VBoxManage -q bandwidthctl "boinc_ebc920a826ebacbb" add "boinc_ebc920a826ebacbb_net" --type network --limit 1024G Exit Code: 0 Output: 2025-07-27 08:59:32 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --natpf1 ",tcp,127.0.0.1,50120,,80" Exit Code: 0 Output: 2025-07-27 08:59:32 (24676): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 7.0.8 Revision: 156879 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: false Why unusable: VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='VirtualBox version mismatch - expected 7.0 got 7.1' 2025-07-27 08:59:32 (24676): Command: VBoxManage -q modifyvm "boinc_ebc920a826ebacbb" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 50124 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-07-27 08:59:32 (24676): Command: VBoxManage -q sharedfolder add "boinc_ebc920a826ebacbb" --name "shared" --hostpath "E:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-07-27 08:59:36 (24676): Command: VBoxManage -q startvm "boinc_ebc920a826ebacbb" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_ebc920a826ebacbb" to power on... 2025-07-27 08:59:36 (24676): Command: VBoxManage -q snapshot "boinc_ebc920a826ebacbb" list Exit Code: -108 Output: This machine does not have any snapshots 2025-07-27 08:59:36 (24676): Command: VBoxManage -q bandwidthctl "boinc_ebc920a826ebacbb" remove "boinc_ebc920a826ebacbb_net" Exit Code: 0 Output: 2025-07-27 08:59:37 (24676): Command: VBoxManage -q unregistervm "boinc_ebc920a826ebacbb" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-07-27 08:59:42 (24676): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN