Name Theory_2922-4886102-89_0
Workunit 233606290
Created 14 Jul 2025, 0:41:26 UTC
Sent 14 Jul 2025, 2:16:38 UTC
Report deadline 25 Jul 2025, 2:16:38 UTC
Received 14 Jul 2025, 3:44:15 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10584891
Run time 3 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.85 GFLOPS
Application version Theory Simulation v300.98 (vbox64_theory)
windows_x86_64
Peak working set size 11.98 MB
Peak swap size 2.21 MB
Peak disk usage 1.11 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2025-07-13 22:25:58 (10264): vboxwrapper version 26210
2025-07-13 22:25:58 (10264): BOINC client version: 8.0.2
2025-07-13 22:25:59 (10264): Detected: VirtualBox VboxManage Interface (Version: 7.0.14)
2025-07-13 22:25:59 (10264): Detected: Heartbeat check (file: 'heartbeat' every 1800.000000 seconds)
2025-07-13 22:25:59 (10264): Successfully copied 'init_data.xml' to the shared directory.
2025-07-13 22:25:59 (10264): Successfully copied 'input' to the shared directory.
2025-07-13 22:25:59 (10264): Create VM. (boinc_064d43e02209f1a7, slot#2)
2025-07-13 22:26:00 (10264): Setting Memory Size for VM. (630MB)
2025-07-13 22:26:00 (10264): Setting CPU Count for VM. (1)
2025-07-13 22:26:00 (10264): Setting Chipset Options for VM.
2025-07-13 22:26:01 (10264): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB)
2025-07-13 22:26:01 (10264): Setting Boot Options for VM.
2025-07-13 22:26:01 (10264): Setting Network Configuration for NAT. (Driver: virtio)
2025-07-13 22:26:02 (10264): Enabling VM Network Access.
2025-07-13 22:26:02 (10264): Disabling USB Support for VM.
2025-07-13 22:26:02 (10264): Disabling COM Port Support for VM.
2025-07-13 22:26:03 (10264): Disabling LPT Port Support for VM.
2025-07-13 22:26:03 (10264): Disabling Audio Support for VM.
2025-07-13 22:26:03 (10264): Disabling Clipboard Support for VM.
2025-07-13 22:26:03 (10264): Disabling Drag and Drop Support for VM.
2025-07-13 22:26:04 (10264): Adding storage controller(s) to VM.
2025-07-13 22:26:04 (10264): Adding virtual disk drive to VM. (Theory_2025_07_03_prod.vdi)
2025-07-13 22:26:06 (10264): Adding VirtualBox Guest Additions to VM.
2025-07-13 22:26:06 (10264): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-07-13 22:26:06 (10264): forwarding host port 61234 to guest port 80
2025-07-13 22:26:07 (10264): Enabling remote desktop for VM.
2025-07-13 22:26:07 (10264): Enabling shared directory for VM.
2025-07-13 22:26:08 (10264): Starting VM using VBoxManage interface. (boinc_064d43e02209f1a7, slot#2)
2025-07-13 22:26:13 (10264): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_064d43e02209f1a7" --type headless
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_064d43e02209f1a7" to power on...

2025-07-13 22:26:13 (10264): VM failed to start.
2025-07-13 22:26:13 (10264): Could not start 
2025-07-13 22:26:13 (10264): ERROR: VM failed to start
2025-07-13 22:26:13 (10264): Powering off VM.
2025-07-13 22:26:13 (10264): Deregistering VM. (boinc_064d43e02209f1a7, slot#2)
2025-07-13 22:26:13 (10264): Removing network bandwidth throttle group from VM.
2025-07-13 22:26:13 (10264): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.120861          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.121024          Saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.123304          Finished saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml"
00:00:07.123724          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:07.125916          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:07.383263          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:07.385384          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:07.658161          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.658712          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:07.660768          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:07.660954          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.662647          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:07.665243          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:07.665748          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:07.668162          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:07.921912          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.934468          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.934629          Saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.936942          Finished saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml"
00:00:07.937286          Saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.939686          Finished saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml"
00:00:07.940066          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:07.942350          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:08.183378          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:08.185427          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:08.452528          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:08.454674          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:08.982253          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:08.984419          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:09.253063          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:09.255155          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:09.512885          ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0
00:00:09.519102          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.519181          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.736311          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.040726          Launched VM: 3478034080 pid: 496 (0x1f0) frontend: headless name: boinc_064d43e02209f1a7
00:00:14.500575          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox" with version "1.19-windows"
00:00:14.506245          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_064d43e02209f1a7\boinc_064d43e02209f1a7.vbox"
00:00:14.561383          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:14.864189          ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_064d43e02209f1a7' while it is locked}, preserve=false aResultDetail=0
00:00:16.130148          Saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.132456          Finished saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml"
00:00:16.132561          Saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.135387          Finished saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml"
00:00:16.136256 DeleteVM Saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.138632 DeleteVM Finished saving settings file "C:\Users\Me\.VirtualBox\VirtualBox.xml"
00:00:21.149591 main     VirtualBox: object deletion starts
00:00:21.153130 main     HostDnsMonitor: shutting down ...
00:00:21.153221 main     HostDnsMonitor: shut down
00:00:21.156274 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:21.156636 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

102-89_0"
GuestMemoryBalloon=0

2025-07-13 22:26:02 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on 
Exit Code: 0
Output:

2025-07-13 22:26:02 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --cable-connected1 on 
Exit Code: 0
Output:

2025-07-13 22:26:02 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --usb off 
Exit Code: 0
Output:

2025-07-13 22:26:03 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-07-13 22:26:03 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-07-13 22:26:03 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --audio-enabled off 
Exit Code: 0
Output:

2025-07-13 22:26:03 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --clipboard disabled 
Exit Code: 0
Output:

2025-07-13 22:26:04 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --draganddrop disabled 
Exit Code: 0
Output:

2025-07-13 22:26:04 (10264): 
Command: VBoxManage -q storagectl "boinc_064d43e02209f1a7" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-07-13 22:26:04 (10264): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" 
Exit Code: 0
Output:
UUID:           93ef7340-8636-46d8-8751-a7cb0c80413d
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       10240 MBytes
Size on disk:   2847 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-07-13 22:26:04 (10264): 
Command: VBoxManage -q storageattach "boinc_064d43e02209f1a7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-07-13 22:26:05 (10264): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" 
Exit Code: 0
Output:
UUID:           93ef7340-8636-46d8-8751-a7cb0c80413d
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       10240 MBytes
Size on disk:   2847 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-07-13 22:26:05 (10264): 
Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi" 
Exit Code: 0
Output:

2025-07-13 22:26:05 (10264): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" 
Exit Code: 0
Output:
UUID:           93ef7340-8636-46d8-8751-a7cb0c80413d
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_07_03_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       10240 MBytes
Size on disk:   2847 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-07-13 22:26:05 (10264): 
Command: VBoxManage -q storageattach "boinc_064d43e02209f1a7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" 
Exit Code: 0
Output:

2025-07-13 22:26:06 (10264): 
Command: VBoxManage -q storageattach "boinc_064d43e02209f1a7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-07-13 22:26:06 (10264): 
Command: VBoxManage -q storageattach "boinc_064d43e02209f1a7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_07_03_prod.vdi" 
Exit Code: 0
Output:

2025-07-13 22:26:06 (10264): 
Command: VBoxManage -q storageattach "boinc_064d43e02209f1a7" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-07-13 22:26:06 (10264): 
Command: VBoxManage -q bandwidthctl "boinc_064d43e02209f1a7" add "boinc_064d43e02209f1a7_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-07-13 22:26:07 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --natpf1 ",tcp,127.0.0.1,61234,,80" 
Exit Code: 0
Output:

2025-07-13 22:26:07 (10264): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:        7.0.14
Revision:       161095
Edition:        
Description:    Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption.
VRDE Module:    VBoxVRDP
Crypto Module:  VBoxPuelCrypto
Usable:         true
Why unusable:   

2025-07-13 22:26:07 (10264): 
Command: VBoxManage -q modifyvm "boinc_064d43e02209f1a7" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 61235 --vrde-property "Security/Method=RDP" 
Exit Code: 0
Output:

2025-07-13 22:26:08 (10264): 
Command: VBoxManage -q sharedfolder add "boinc_064d43e02209f1a7" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared"
Exit Code: 0
Output:

2025-07-13 22:26:13 (10264): 
Command: VBoxManage -q startvm "boinc_064d43e02209f1a7" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_064d43e02209f1a7" to power on...

2025-07-13 22:26:13 (10264): 
Command: VBoxManage -q snapshot "boinc_064d43e02209f1a7" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-07-13 22:26:13 (10264): 
Command: VBoxManage -q bandwidthctl "boinc_064d43e02209f1a7" remove "boinc_064d43e02209f1a7_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2025-07-13 22:26:13 (10264): 
Command: VBoxManage -q unregistervm "boinc_064d43e02209f1a7" --delete 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot unregister the machine 'boinc_064d43e02209f1a7' while it is locked
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component MachineWrap, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "Unregister(fDeleteAll ? CleanupMode_DetachAllReturnHardDisksAndVMRemovable :CleanupMode_DetachAllReturnHardDisksOnly, ComSafeArrayAsOutParam(aMedia))" at line 236 of file VBoxManageMisc.cpp

2025-07-13 22:26:14 (10264): 
Command: VBoxManage -q unregistervm "boinc_064d43e02209f1a7" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-07-13 22:26:20 (10264): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 CERN