Name Theory_2914-4659107-47_1
Workunit 232963462
Created 10 Jun 2025, 15:43:47 UTC
Sent 10 Jun 2025, 21:13:25 UTC
Report deadline 21 Jun 2025, 21:13:25 UTC
Received 10 Jun 2025, 21:53:48 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10664728
Run time 21 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.02 GFLOPS
Application version Theory Simulation v300.95 (vbox64_theory)
windows_x86_64
Peak working set size 10.21 MB
Peak swap size 2.11 MB
Peak disk usage 1.43 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2025-06-10 17:14:16 (10204): vboxwrapper version 26210
2025-06-10 17:14:16 (10204): BOINC client version: 7.16.11
2025-06-10 17:14:16 (10204): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2025-06-10 17:14:17 (10204): Detected: Heartbeat check (file: 'heartbeat' every 1800.000000 seconds)
2025-06-10 17:14:17 (10204): Successfully copied 'init_data.xml' to the shared directory.
2025-06-10 17:14:17 (10204): Successfully copied 'input' to the shared directory.
2025-06-10 17:14:17 (10204): Create VM. (boinc_9b36014406f673f8, slot#2)
2025-06-10 17:14:17 (10204): Setting Memory Size for VM. (630MB)
2025-06-10 17:14:18 (10204): Setting CPU Count for VM. (1)
2025-06-10 17:14:18 (10204): Setting Chipset Options for VM.
2025-06-10 17:14:18 (10204): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB)
2025-06-10 17:14:18 (10204): Setting Boot Options for VM.
2025-06-10 17:14:19 (10204): Setting Network Configuration for NAT. (Driver: virtio)
2025-06-10 17:14:19 (10204): Enabling VM Network Access.
2025-06-10 17:14:19 (10204): Disabling USB Support for VM.
2025-06-10 17:14:20 (10204): Disabling COM Port Support for VM.
2025-06-10 17:14:20 (10204): Disabling LPT Port Support for VM.
2025-06-10 17:14:20 (10204): Disabling Audio Support for VM.
2025-06-10 17:14:20 (10204): Disabling Clipboard Support for VM.
2025-06-10 17:14:21 (10204): Disabling Drag and Drop Support for VM.
2025-06-10 17:14:21 (10204): Adding storage controller(s) to VM.
2025-06-10 17:14:21 (10204): Adding virtual disk drive to VM. (Theory_2025_04_17_prod.vdi)
2025-06-10 17:14:26 (10204): Attempts: 4
2025-06-10 17:14:26 (10204): Adding VirtualBox Guest Additions to VM.
2025-06-10 17:14:26 (10204): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-06-10 17:14:27 (10204): forwarding host port 59150 to guest port 80
2025-06-10 17:14:27 (10204): Enabling remote desktop for VM.
2025-06-10 17:14:27 (10204): Required extension pack not installed, remote desktop not enabled.
2025-06-10 17:14:27 (10204): Enabling shared directory for VM.
2025-06-10 17:14:28 (10204): Starting VM using VBoxManage interface. (boinc_9b36014406f673f8, slot#2)
2025-06-10 17:14:30 (10204): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_9b36014406f673f8" --type headless
Output:
Waiting for VM "boinc_9b36014406f673f8" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2025-06-10 17:14:30 (10204): VM failed to start.
2025-06-10 17:14:30 (10204): Could not start 
2025-06-10 17:14:30 (10204): ERROR: VM failed to start
2025-06-10 17:14:30 (10204): Powering off VM.
2025-06-10 17:14:30 (10204): Deregistering VM. (boinc_9b36014406f673f8, slot#2)
2025-06-10 17:14:30 (10204): Removing network bandwidth throttle group from VM.
2025-06-10 17:14:30 (10204): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:12.629664          Launched VM: 61726384 pid: 9376 (0x24a0) frontend: headless name: boinc_9b36014406f673f8
00:00:12.656496          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:12.658366          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.705426          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:12.951954          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:12.952271          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:12.952330          Saving settings file "C:\Users\Nate\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.958544          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:12.958710          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_a36d4491c2dd28f0\boinc_a36d4491c2dd28f0.vbox" with version "1.16-windows"
00:00:12.966026 DeleteVM ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:12.966326 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_a36d4491c2dd28f0\boinc_a36d4491c2dd28f0.vbox" with version "1.16-windows"
00:00:13.171607          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_a36d4491c2dd28f0\boinc_a36d4491c2dd28f0.vbox" with version "1.16-windows"
00:00:13.229908          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.231490          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:13.271322          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.526761          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.527082          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.527154          Saving settings file "C:\Users\Nate\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:13.533615          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.533873          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_68a26fe298ccd37f\boinc_68a26fe298ccd37f.vbox" with version "1.16-windows"
00:00:13.541290 DeleteVM ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.541594 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_68a26fe298ccd37f\boinc_68a26fe298ccd37f.vbox" with version "1.16-windows"
00:00:13.701121          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_68a26fe298ccd37f\boinc_68a26fe298ccd37f.vbox" with version "1.16-windows"
00:00:13.756642          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.758415          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:13.800168          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.056966          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.057233          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.057291          Saving settings file "C:\Users\Nate\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.063713          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.063862          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_9b36014406f673f8\boinc_9b36014406f673f8.vbox" with version "1.16-windows"
00:00:14.070644 DeleteVM ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.070850 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_9b36014406f673f8\boinc_9b36014406f673f8.vbox" with version "1.16-windows"
00:00:14.793766          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_9b36014406f673f8\boinc_9b36014406f673f8.vbox" with version "1.16-windows"
00:00:14.848392          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.849989          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:14.889685          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:15.144468          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:15.144731          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:15.144786          Saving settings file "C:\Users\Nate\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:20.156615 main     VirtualBox: object deletion starts
00:00:20.157121 main     HostDnsMonitor: shutting down ...
00:00:20.157174 main     HostDnsMonitor: shut down
00:00:20.160507 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:20.160746 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

at line 2715 of file VBoxManageInfo.cpp

2025-06-10 17:14:17 (10204): 
Command: VBoxManage -q createvm --name "boinc_9b36014406f673f8" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_9b36014406f673f8' is created and registered.
UUID: 08de2399-4015-4e5c-bf5a-4c29e006f907
Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_9b36014406f673f8\boinc_9b36014406f673f8.vbox'

2025-06-10 17:14:17 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --description "Theory_2914-4659107-47_1" 
Exit Code: 0
Output:

2025-06-10 17:14:18 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --memory 630 
Exit Code: 0
Output:

2025-06-10 17:14:18 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --cpus 1 
Exit Code: 0
Output:

2025-06-10 17:14:18 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-06-10 17:14:18 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-06-10 17:14:19 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-06-10 17:14:19 (10204): 
Command: VBoxManage -q showvminfo "boinc_9b36014406f673f8" --machinereadable 
Exit Code: 0
Output:
name="boinc_9b36014406f673f8"
groups="/"
ostype="Linux 2.6 / 3.x / 4.x (64-bit)"
UUID="08de2399-4015-4e5c-bf5a-4c29e006f907"
CfgFile="C:\\ProgramData\\BOINC\\slots\\2\\boinc_9b36014406f673f8\\boinc_9b36014406f673f8.vbox"
SnapFldr="C:\\ProgramData\\BOINC\\slots\\2\\boinc_9b36014406f673f8\\Snapshots"
LogFldr="C:\\ProgramData\\BOINC\\slots\\2\\boinc_9b36014406f673f8\\Logs"
hardwareuuid="08de2399-4015-4e5c-bf5a-4c29e006f907"
memory=630
pagefusion="off"
vram=16
cpuexecutioncap=100
hpet="off"
cpu-profile="host"
chipset="piix3"
firmware="BIOS"
cpus=1
pae="on"
longmode="on"
triplefaultreset="off"
apic="on"
x2apic="on"
nested-hw-virt="off"
cpuid-portability-level=0
bootmenu="messageandmenu"
boot1="disk"
boot2="dvd"
boot3="none"
boot4="none"
acpi="on"
ioapic="on"
biosapic="apic"
biossystemtimeoffset=0
rtcuseutc="off"
hwvirtex="on"
nestedpaging="on"
largepages="on"
vtxvpid="on"
vtxux="on"
paravirtprovider="default"
effparavirtprovider="kvm"
VMState="poweroff"
VMStateChangeTime="2025-06-10T21:14:17.338000000"
graphicscontroller="vboxvga"
monitorcount=1
accelerate3d="off"
accelerate2dvideo="off"
teleporterenabled="off"
teleporterport=0
teleporteraddress=""
teleporterpassword=""
tracing-enabled="off"
tracing-allow-vm-access="off"
tracing-config=""
autostart-enabled="off"
autostart-delay=0
defaultfrontend=""
vmprocpriority="default"
natnet1="nat"
macaddress1="08002723DCA6"
cableconnected1="on"
nic1="nat"
nictype1="82540EM"
nicspeed1="0"
mtu="0"
sockSnd="64"
sockRcv="64"
tcpWndSnd="64"
tcpWndRcv="64"
nic2="none"
nic3="none"
nic4="none"
nic5="none"
nic6="none"
nic7="none"
nic8="none"
hidpointing="ps2mouse"
hidkeyboard="ps2kbd"
uart1="off"
uart2="off"
uart3="off"
uart4="off"
lpt1="off"
lpt2="off"
audio="dsound"
audio_out="off"
audio_in="off"
clipboard="disabled"
draganddrop="disabled"
vrde="off"
usb="off"
ehci="off"
xhci="off"
videocap="off"
videocapaudio="off"
capturescreens=""
capturefilename="C:\\ProgramData\\BOINC\\slots\\2\\boinc_9b36014406f673f8\\boinc_9b36014406f673f8.webm"
captureres="1024x768"
capturevideorate=512
capturevideofps=25
captureopts=""
description="Theory_2914-4659107-47_1"
GuestMemoryBalloon=0

2025-06-10 17:14:19 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --nic1 nat --nictype1 "virtio" --cableconnected1 off --natdnsproxy1 on 
Exit Code: 0
Output:

2025-06-10 17:14:19 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --cableconnected1 on 
Exit Code: 0
Output:

2025-06-10 17:14:20 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --usb off 
Exit Code: 0
Output:

2025-06-10 17:14:20 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-06-10 17:14:20 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-06-10 17:14:20 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --audio none 
Exit Code: 0
Output:

2025-06-10 17:14:21 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --clipboard disabled 
Exit Code: 0
Output:

2025-06-10 17:14:21 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --draganddrop disabled 
Exit Code: 0
Output:

2025-06-10 17:14:21 (10204): 
Command: VBoxManage -q storagectl "boinc_9b36014406f673f8" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-06-10 17:14:26 (10204): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:
UUID:           b1b25507-41e2-4ead-9ca8-6f5e1c8e2ce4
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       10240 MBytes
Size on disk:   2451 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576
Child UUIDs:    3dc936f6-0677-407c-9755-dcce483a5602
                f4912510-36f9-4e7d-bccc-f406092b16e1
                e0ed9b7b-d355-4fc2-a6d2-669de27a0ad0
                7a6cdff4-882d-40d9-b8d5-06d36e37f1df
                0d09a472-bb4a-4ffa-a46f-203d152fc234

2025-06-10 17:14:26 (10204): 
Command: VBoxManage -q storageattach "boinc_9b36014406f673f8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:

2025-06-10 17:14:26 (10204): 
Command: VBoxManage -q storageattach "boinc_9b36014406f673f8" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-06-10 17:14:27 (10204): 
Command: VBoxManage -q bandwidthctl "boinc_9b36014406f673f8" add "boinc_9b36014406f673f8_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-06-10 17:14:27 (10204): 
Command: VBoxManage -q modifyvm "boinc_9b36014406f673f8" --natpf1 ",tcp,127.0.0.1,59150,,80" 
Exit Code: 0
Output:

2025-06-10 17:14:27 (10204): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-06-10 17:14:27 (10204): 
Command: VBoxManage -q sharedfolder add "boinc_9b36014406f673f8" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared"
Exit Code: 0
Output:

2025-06-10 17:14:30 (10204): 
Command: VBoxManage -q startvm "boinc_9b36014406f673f8" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_9b36014406f673f8" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2025-06-10 17:14:30 (10204): 
Command: VBoxManage -q snapshot "boinc_9b36014406f673f8" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-06-10 17:14:30 (10204): 
Command: VBoxManage -q bandwidthctl "boinc_9b36014406f673f8" remove "boinc_9b36014406f673f8_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2025-06-10 17:14:30 (10204): 
Command: VBoxManage -q unregistervm "boinc_9b36014406f673f8" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-06-10 17:14:35 (10204): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 CERN