Name | HDlNDmdFwc7n9Rq4apOajLDm4fhM0noT9bVof3QYDmlLLKDmOe9xsm_1 |
Workunit | 232549955 |
Created | 24 May 2025, 6:07:24 UTC |
Sent | 24 May 2025, 6:47:40 UTC |
Report deadline | 1 Jun 2025, 6:47:40 UTC |
Received | 24 May 2025, 7:15:49 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -1073741819 (0xC0000005) STATUS_ACCESS_VIOLATION |
Computer ID | 10772314 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 31.59 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 12.60 MB |
Peak swap size | 5.60 MB |
Peak disk usage | 214.03 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> (unknown error) (317) - exit code 3221225477 (0xc0000005)</message> <stderr_txt> 2025-05-24 08:49:23 (15396): Detected: vboxwrapper 26206 2025-05-24 08:49:23 (15396): Detected: BOINC client v7.24.1 2025-05-24 08:49:24 (15396): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-05-24 08:49:24 (15396): Successfully copied 'init_data.xml' to the shared directory. 2025-05-24 08:49:24 (15396): Create VM. (boinc_62e5ac6631162cff, slot#8) 2025-05-24 08:49:25 (15396): Setting Memory Size for VM. (4600MB) 2025-05-24 08:49:25 (15396): Setting CPU Count for VM. (6) 2025-05-24 08:49:26 (15396): Setting Chipset Options for VM. 2025-05-24 08:49:26 (15396): Setting Graphics Controller Options for VM. 2025-05-24 08:49:26 (15396): Setting Boot Options for VM. 2025-05-24 08:49:26 (15396): Setting Network Configuration for NAT. 2025-05-24 08:49:27 (15396): Enabling VM Network Access. 2025-05-24 08:49:27 (15396): Disabling USB Support for VM. 2025-05-24 08:49:27 (15396): Disabling COM Port Support for VM. 2025-05-24 08:49:27 (15396): Disabling LPT Port Support for VM. 2025-05-24 08:49:28 (15396): Disabling Audio Support for VM. 2025-05-24 08:49:28 (15396): Disabling Clipboard Support for VM. 2025-05-24 08:49:28 (15396): Disabling Drag and Drop Support for VM. 2025-05-24 08:49:28 (15396): Adding storage controller(s) to VM. 2025-05-24 08:49:29 (15396): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-05-24 08:49:32 (15396): Adding VirtualBox Guest Additions to VM. 2025-05-24 08:49:32 (15396): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-05-24 08:49:32 (15396): forwarding host port 65440 to guest port 80 2025-05-24 08:49:32 (15396): Enabling remote desktop for VM. 2025-05-24 08:49:33 (15396): Required extension pack not installed, remote desktop not enabled. 2025-05-24 08:49:33 (15396): Enabling shared directory for VM. 2025-05-24 08:49:33 (15396): Starting VM using VBoxManage interface. (boinc_62e5ac6631162cff, slot#8) 2025-05-24 08:49:34 (15396): Error in start VM for VM: -1073741819 Command: VBoxManage -q startvm "boinc_62e5ac6631162cff" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_62e5ac6631162cff' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_62e5ac6631162cff" to power on... 2025-05-24 08:49:34 (15396): VM failed to start. 2025-05-24 08:49:34 (15396): Could not start 2025-05-24 08:49:34 (15396): ERROR: VM failed to start 2025-05-24 08:49:34 (15396): Powering off VM. 2025-05-24 08:49:34 (15396): Deregistering VM. (boinc_62e5ac6631162cff, slot#8) 2025-05-24 08:49:34 (15396): Removing network bandwidth throttle group from VM. 2025-05-24 08:49:34 (15396): Removing VM from VirtualBox. Hypervisor System Log: 00:00:06.072015 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:07.585298 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.585736 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.585926 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.590377 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:07.590731 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:07.593812 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:07.841498 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:07.845751 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:08.095365 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.096229 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:08.101358 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:08.101492 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.103411 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:08.106464 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:08.106849 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:08.109948 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:08.367346 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.368843 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.369010 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.373191 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:08.373419 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.376163 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:08.376434 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:08.379552 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:08.625540 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:08.630480 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:08.883987 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:08.888462 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:09.421142 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:09.424535 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:09.689197 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.697324 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.697425 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.706728 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.948655 Launched VM: 1344320256 pid: 21584 (0x5450) frontend: headless name: boinc_62e5ac6631162cff 00:00:10.802160 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_62e5ac6631162cff' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005)}, preserve=false aResultDetail=0 00:00:10.878126 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.941128 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" with version "1.19-windows" 00:00:10.944873 Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox" 00:00:11.198584 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.203030 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:11.203147 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.205813 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:11.206470 DeleteVM Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.210055 DeleteVM Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:16.217350 main VirtualBox: object deletion starts 00:00:16.217953 main HostDnsMonitor: shutting down ... 00:00:16.217984 main HostDnsMonitor: shut down 00:00:16.219216 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.219452 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: pp 2025-05-24 08:49:24 (15396): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\8/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-05-24 08:49:25 (15396): Command: VBoxManage -q createvm --name "boinc_62e5ac6631162cff" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_62e5ac6631162cff' is created and registered. UUID: f0cc2c8a-880b-440a-a805-18d363bcc66d Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_62e5ac6631162cff\boinc_62e5ac6631162cff.vbox' 2025-05-24 08:49:25 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --description "HDlNDmdFwc7n9Rq4apOajLDm4fhM0noT9bVof3QYDmlLLKDmOe9xsm_1" Exit Code: 0 Output: 2025-05-24 08:49:25 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --memory 4600 Exit Code: 0 Output: 2025-05-24 08:49:26 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --cpus 6 Exit Code: 0 Output: 2025-05-24 08:49:26 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-05-24 08:49:26 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-05-24 08:49:26 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-05-24 08:49:27 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-05-24 08:49:27 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --cableconnected1 on Exit Code: 0 Output: 2025-05-24 08:49:27 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --usb off Exit Code: 0 Output: 2025-05-24 08:49:27 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --uart1 off --uart2 off Exit Code: 0 Output: 2025-05-24 08:49:28 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-05-24 08:49:28 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-05-24 08:49:28 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --clipboard disabled Exit Code: 0 Output: 2025-05-24 08:49:28 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --draganddrop disabled Exit Code: 0 Output: 2025-05-24 08:49:29 (15396): Command: VBoxManage -q storagectl "boinc_62e5ac6631162cff" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-05-24 08:49:29 (15396): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-05-24 08:49:29 (15396): Command: VBoxManage -q storageattach "boinc_62e5ac6631162cff" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-05-24 08:49:30 (15396): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-05-24 08:49:31 (15396): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-05-24 08:49:31 (15396): Command: VBoxManage -q storageattach "boinc_62e5ac6631162cff" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-05-24 08:49:31 (15396): Command: VBoxManage -q storageattach "boinc_62e5ac6631162cff" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-05-24 08:49:32 (15396): Command: VBoxManage -q storageattach "boinc_62e5ac6631162cff" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-05-24 08:49:32 (15396): Command: VBoxManage -q storageattach "boinc_62e5ac6631162cff" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-05-24 08:49:32 (15396): Command: VBoxManage -q bandwidthctl "boinc_62e5ac6631162cff" add "boinc_62e5ac6631162cff_net" --type network --limit 1024G Exit Code: 0 Output: 2025-05-24 08:49:32 (15396): Command: VBoxManage -q modifyvm "boinc_62e5ac6631162cff" --natpf1 ",tcp,127.0.0.1,65440,,80" Exit Code: 0 Output: 2025-05-24 08:49:33 (15396): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-05-24 08:49:33 (15396): Command: VBoxManage -q sharedfolder add "boinc_62e5ac6631162cff" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared" Exit Code: 0 Output: 2025-05-24 08:49:34 (15396): Command: VBoxManage -q startvm "boinc_62e5ac6631162cff" --type headless Exit Code: -1073741819 Output: VBoxManage.exe: error: The virtual machine 'boinc_62e5ac6631162cff' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_62e5ac6631162cff" to power on... 2025-05-24 08:49:34 (15396): Command: VBoxManage -q snapshot "boinc_62e5ac6631162cff" list Exit Code: -108 Output: This machine does not have any snapshots 2025-05-24 08:49:34 (15396): Command: VBoxManage -q bandwidthctl "boinc_62e5ac6631162cff" remove "boinc_62e5ac6631162cff_net" Exit Code: 0 Output: 2025-05-24 08:49:35 (15396): Command: VBoxManage -q unregistervm "boinc_62e5ac6631162cff" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 08:49:40 (15396): called boinc_finish(-1073741819) </stderr_txt> ]]>
©2025 CERN