Name | Theory_2848-4463386-997_0 |
Workunit | 232441453 |
Created | 20 May 2025, 6:02:13 UTC |
Sent | 20 May 2025, 11:01:13 UTC |
Report deadline | 31 May 2025, 11:01:13 UTC |
Received | 21 May 2025, 0:51:58 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10751443 |
Run time | 7 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 1.97 GFLOPS |
Application version | Theory Simulation v300.95 (vbox64_theory) windows_x86_64 |
Peak working set size | 10.75 MB |
Peak swap size | 6.39 MB |
Peak disk usage | 1.10 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Unbekannter Fehler (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-05-20 23:07:32 (10888): vboxwrapper version 26210 2025-05-20 23:07:32 (10888): BOINC client version: 8.0.4 2025-05-20 23:07:37 (10888): Detected: VirtualBox VboxManage Interface (Version: 7.1.6) 2025-05-20 23:07:37 (10888): Detected: Heartbeat check (file: 'heartbeat' every 1800.000000 seconds) 2025-05-20 23:07:37 (10888): Successfully copied 'init_data.xml' to the shared directory. 2025-05-20 23:07:37 (10888): Successfully copied 'input' to the shared directory. 2025-05-20 23:07:37 (10888): Create VM. (boinc_2335b88b44c54c92, slot#0) 2025-05-20 23:07:38 (10888): Setting Memory Size for VM. (630MB) 2025-05-20 23:07:39 (10888): Setting CPU Count for VM. (1) 2025-05-20 23:07:39 (10888): Setting Chipset Options for VM. 2025-05-20 23:07:39 (10888): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB) 2025-05-20 23:07:40 (10888): Setting Boot Options for VM. 2025-05-20 23:07:41 (10888): Setting Network Configuration for NAT. (Driver: virtio) 2025-05-20 23:07:41 (10888): Enabling VM Network Access. 2025-05-20 23:07:41 (10888): Disabling USB Support for VM. 2025-05-20 23:07:42 (10888): Disabling COM Port Support for VM. 2025-05-20 23:07:42 (10888): Disabling LPT Port Support for VM. 2025-05-20 23:07:42 (10888): Disabling Audio Support for VM. 2025-05-20 23:07:42 (10888): Disabling Clipboard Support for VM. 2025-05-20 23:07:43 (10888): Disabling Drag and Drop Support for VM. 2025-05-20 23:07:43 (10888): Adding storage controller(s) to VM. 2025-05-20 23:07:44 (10888): Adding virtual disk drive to VM. (Theory_2025_04_17_prod.vdi) 2025-05-20 23:07:47 (10888): Adding VirtualBox Guest Additions to VM. 2025-05-20 23:07:47 (10888): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-05-20 23:07:47 (10888): forwarding host port 56440 to guest port 80 2025-05-20 23:07:48 (10888): Enabling remote desktop for VM. 2025-05-20 23:07:49 (10888): Enabling shared directory for VM. 2025-05-20 23:07:49 (10888): Starting VM using VBoxManage interface. (boinc_2335b88b44c54c92, slot#0) 2025-05-20 23:08:00 (10888): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_2335b88b44c54c92" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_2335b88b44c54c92" to power on... 2025-05-20 23:08:00 (10888): VM failed to start. 2025-05-20 23:08:00 (10888): Could not start 2025-05-20 23:08:00 (10888): ERROR: VM failed to start 2025-05-20 23:08:00 (10888): Powering off VM. 2025-05-20 23:08:00 (10888): Deregistering VM. (boinc_2335b88b44c54c92, slot#0) 2025-05-20 23:08:01 (10888): Removing network bandwidth throttle group from VM. 2025-05-20 23:08:01 (10888): Removing VM from VirtualBox. Hypervisor System Log: 00:00:12.734077 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:12.734295 Saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.758516 Finished saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" 00:00:12.760227 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" with version "1.19-windows" 00:00:12.791987 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" 00:00:13.163448 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.168478 Platform architecture set to 'x86' 00:00:13.174589 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" with version "1.19-windows" 00:00:13.200349 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" 00:00:13.457043 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.464690 Platform architecture set to 'x86' 00:00:13.475699 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" with version "1.19-windows" 00:00:13.500915 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" 00:00:14.018744 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.025292 Platform architecture set to 'x86' 00:00:14.047339 VRDE: Generating certificate files 'C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\VRDEAutoGeneratedCert.pem' and 'C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\VRDEAutoGeneratedPrivateKey.pem'... 00:00:14.193520 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" with version "1.19-windows" 00:00:14.221788 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" 00:00:14.571924 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.576948 Platform architecture set to 'x86' 00:00:14.583365 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" with version "1.19-windows" 00:00:14.616439 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" 00:00:14.824003 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.829133 Platform architecture set to 'x86' 00:00:14.837039 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:14.858240 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.858550 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:14.886634 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={bea3ef5c-de2f-4b74-aa3a-15d6249371a0} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0 00:00:14.890129 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.117850 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:15.145630 Launched VM: 2439648272 pid: 2060 (0x80c) frontend: headless name: boinc_2335b88b44c54c92 00:00:23.072814 Platform architecture set to 'x86' 00:00:26.156787 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" with version "1.19-windows" 00:00:26.225594 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" 00:00:26.517556 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:26.533517 Platform architecture set to 'x86' 00:00:26.558887 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:26.824755 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:26.830089 Platform architecture set to 'x86' 00:00:26.836472 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" with version "1.19-windows" 00:00:26.867492 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2335b88b44c54c92\boinc_2335b88b44c54c92.vbox" 00:00:27.072935 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:27.087466 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:27.087705 Saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:27.124862 Finished saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" 00:00:27.125169 Saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:27.150537 Finished saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" 00:00:27.163702 DeleteVM Saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:27.203420 DeleteVM Finished saving settings file "C:\Users\cbrom\.VirtualBox\VirtualBox.xml" 00:00:32.234777 main VirtualBox: object deletion starts 00:00:32.241758 main HostDnsMonitor: shutting down ... 00:00:32.241898 main HostDnsMonitor: shut down 00:00:32.247550 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:32.248785 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: xhci="off" recording_started="off" recording_enabled="off" recording_screens=1 rec_screen0 rec_screen_enabled="on" rec_screen_id=0 rec_screen_video_enabled="on" rec_screen_audio_enabled="off" rec_screen_dest="File" rec_screen_dest_filename="C:\\ProgramData\\BOINC\\slots\\0\\boinc_2335b88b44c54c92\\boinc_2335b88b44c54c92-screen0.webm" rec_screen_opts="vc_enabled=true,ac_enabled=false,ac_profile=med" rec_screen_video_res_xy="1024x768" rec_screen_video_rate_kbps=512 rec_screen_video_fps=25 description="Theory_2848-4463386-997_0" GuestMemoryBalloon=0 2025-05-20 23:07:41 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on Exit Code: 0 Output: 2025-05-20 23:07:41 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --cable-connected1 on Exit Code: 0 Output: 2025-05-20 23:07:42 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --usb off Exit Code: 0 Output: 2025-05-20 23:07:42 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --uart1 off --uart2 off Exit Code: 0 Output: 2025-05-20 23:07:42 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-05-20 23:07:42 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --audio-enabled off Exit Code: 0 Output: 2025-05-20 23:07:43 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --clipboard disabled Exit Code: 0 Output: 2025-05-20 23:07:43 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --draganddrop disabled Exit Code: 0 Output: 2025-05-20 23:07:44 (10888): Command: VBoxManage -q storagectl "boinc_2335b88b44c54c92" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-05-20 23:07:44 (10888): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" Exit Code: 0 Output: UUID: b1b25507-41e2-4ead-9ca8-6f5e1c8e2ce4 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 10240 MBytes Size on disk: 2451 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-05-20 23:07:44 (10888): Command: VBoxManage -q storageattach "boinc_2335b88b44c54c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp 2025-05-20 23:07:45 (10888): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" Exit Code: 0 Output: UUID: b1b25507-41e2-4ead-9ca8-6f5e1c8e2ce4 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 10240 MBytes Size on disk: 2451 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-05-20 23:07:45 (10888): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi" Exit Code: 0 Output: 2025-05-20 23:07:45 (10888): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" Exit Code: 0 Output: UUID: b1b25507-41e2-4ead-9ca8-6f5e1c8e2ce4 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 10240 MBytes Size on disk: 2451 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-05-20 23:07:46 (10888): Command: VBoxManage -q storageattach "boinc_2335b88b44c54c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" Exit Code: 0 Output: 2025-05-20 23:07:46 (10888): Command: VBoxManage -q storageattach "boinc_2335b88b44c54c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-05-20 23:07:47 (10888): Command: VBoxManage -q storageattach "boinc_2335b88b44c54c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" Exit Code: 0 Output: 2025-05-20 23:07:47 (10888): Command: VBoxManage -q storageattach "boinc_2335b88b44c54c92" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-05-20 23:07:47 (10888): Command: VBoxManage -q bandwidthctl "boinc_2335b88b44c54c92" add "boinc_2335b88b44c54c92_net" --type network --limit 1024G Exit Code: 0 Output: 2025-05-20 23:07:48 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --natpf1 ",tcp,127.0.0.1,56440,,80" Exit Code: 0 Output: 2025-05-20 23:07:48 (10888): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 6.1.32 Revision: 149290 Edition: Description: Oracle Cloud Infrastructure integration, USB 2.0 and USB 3.0 Host Controller, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe. VRDE Module: VBoxVRDP Crypto Module: Usable: false Why unusable: VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='Helper version mismatch - expected 0x30000 got 0x50000' 2025-05-20 23:07:49 (10888): Command: VBoxManage -q modifyvm "boinc_2335b88b44c54c92" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 56441 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-05-20 23:07:49 (10888): Command: VBoxManage -q sharedfolder add "boinc_2335b88b44c54c92" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-05-20 23:08:00 (10888): Command: VBoxManage -q startvm "boinc_2335b88b44c54c92" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_2335b88b44c54c92" to power on... 2025-05-20 23:08:01 (10888): Command: VBoxManage -q snapshot "boinc_2335b88b44c54c92" list Exit Code: -108 Output: This machine does not have any snapshots 2025-05-20 23:08:01 (10888): Command: VBoxManage -q bandwidthctl "boinc_2335b88b44c54c92" remove "boinc_2335b88b44c54c92_net" Exit Code: 0 Output: 2025-05-20 23:08:02 (10888): Command: VBoxManage -q unregistervm "boinc_2335b88b44c54c92" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-05-20 23:08:07 (10888): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN