Name Theory_2848-4564776-726_0
Workunit 231932504
Created 28 Apr 2025, 9:46:35 UTC
Sent 28 Apr 2025, 16:03:48 UTC
Report deadline 9 May 2025, 16:03:48 UTC
Received 28 Apr 2025, 19:11:25 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10816018
Run time 28 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.06 GFLOPS
Application version Theory Simulation v300.95 (vbox64_theory)
windows_x86_64
Peak working set size 11.16 MB
Peak swap size 7.59 MB
Peak disk usage 1.44 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Unbekannter Fehler
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2025-04-28 18:04:00 (16532): vboxwrapper version 26210
2025-04-28 18:04:00 (16532): BOINC client version: 8.0.2
2025-04-28 18:04:01 (16532): Detected: VirtualBox VboxManage Interface (Version: 7.0.20)
2025-04-28 18:04:01 (16532): Detected: Heartbeat check (file: 'heartbeat' every 1800.000000 seconds)
2025-04-28 18:04:01 (16532): Successfully copied 'init_data.xml' to the shared directory.
2025-04-28 18:04:01 (16532): Successfully copied 'input' to the shared directory.
2025-04-28 18:04:01 (16532): Create VM. (boinc_d0f263b104c82007, slot#1)
2025-04-28 18:04:02 (16532): Setting Memory Size for VM. (630MB)
2025-04-28 18:04:02 (16532): Setting CPU Count for VM. (1)
2025-04-28 18:04:02 (16532): Setting Chipset Options for VM.
2025-04-28 18:04:03 (16532): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB)
2025-04-28 18:04:03 (16532): Setting Boot Options for VM.
2025-04-28 18:04:03 (16532): Setting Network Configuration for NAT. (Driver: virtio)
2025-04-28 18:04:04 (16532): Enabling VM Network Access.
2025-04-28 18:04:04 (16532): Disabling USB Support for VM.
2025-04-28 18:04:04 (16532): Disabling COM Port Support for VM.
2025-04-28 18:04:05 (16532): Disabling LPT Port Support for VM.
2025-04-28 18:04:05 (16532): Disabling Audio Support for VM.
2025-04-28 18:04:05 (16532): Disabling Clipboard Support for VM.
2025-04-28 18:04:05 (16532): Disabling Drag and Drop Support for VM.
2025-04-28 18:04:06 (16532): Adding storage controller(s) to VM.
2025-04-28 18:04:06 (16532): Adding virtual disk drive to VM. (Theory_2025_04_17_prod.vdi)
2025-04-28 18:04:08 (16532): Adding VirtualBox Guest Additions to VM.
2025-04-28 18:04:08 (16532): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-04-28 18:04:09 (16532): forwarding host port 49982 to guest port 80
2025-04-28 18:04:09 (16532): Enabling remote desktop for VM.
2025-04-28 18:04:10 (16532): Enabling shared directory for VM.
2025-04-28 18:04:11 (16532): Starting VM using VBoxManage interface. (boinc_d0f263b104c82007, slot#1)
2025-04-28 18:04:14 (16532): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_d0f263b104c82007" --type headless
Output:
VBoxManage.exe: error: Failed to launch the Remote Desktop Extension server (VERR_GENERAL_FAILURE)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_d0f263b104c82007" to power on...

2025-04-28 18:04:14 (16532): VM failed to start.
2025-04-28 18:04:14 (16532): Could not start 
2025-04-28 18:04:14 (16532): ERROR: VM failed to start
2025-04-28 18:04:14 (16532): Powering off VM.
2025-04-28 18:04:14 (16532): Deregistering VM. (boinc_d0f263b104c82007, slot#1)
2025-04-28 18:04:14 (16532): Removing network bandwidth throttle group from VM.
2025-04-28 18:04:15 (16532): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:50.274500          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.274663          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.274708          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.274745          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.276719          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox" with version "1.19-windows"
00:00:50.283107          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox"
00:00:50.564216          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.564265          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.564302          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.569980          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox" with version "1.19-windows"
00:00:50.623240          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox"
00:00:50.849369          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.849425          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.849464          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:50.856471          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox" with version "1.19-windows"
00:00:50.861816          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox"
00:00:51.420081          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.420131          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.420264          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.428648          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox" with version "1.19-windows"
00:00:51.472971          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox"
00:00:51.698797          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.698847          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.698885          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.704755          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox" with version "1.19-windows"
00:00:51.746647          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox"
00:00:51.999080          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.999131          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:51.999168          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:52.003379          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={431685da-3618-4ebc-b038-833ba829b4b2} aComponent={ExtPackWrap} aText={Failed to locate the cryptographic module 'VBoxPuelCrypto' in extension pack 'Oracle VM VirtualBox Extension Pack'}, preserve=false aResultDetail=0
00:00:52.003433          ERROR [COM]: aRC=VBOX_E_IPRT_ERROR (0x80bb0005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Couldn't resolve the library path of the crpytographic support module for extension pack 'Oracle VM VirtualBox Extension Pack'}, preserve=false aResultDetail=-1
00:00:52.013993          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:52.014255          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:52.448649          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:52.770492          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:52.770543          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:52.770582          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:52.779098          Launched VM: 2674965088 pid: 16992 (0x4260) frontend: headless name: boinc_b77fb75c7ba377ef
00:00:56.224913          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox" with version "1.19-windows"
00:00:56.230826          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b77fb75c7ba377ef\boinc_b77fb75c7ba377ef.vbox"

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

68"
rec_screen_video_rate_kbps=512
rec_screen_video_fps=25
description="Theory_2848-4564776-726_0"
GuestMemoryBalloon=0

2025-04-28 18:04:04 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on 
Exit Code: 0
Output:

2025-04-28 18:04:04 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --cable-connected1 on 
Exit Code: 0
Output:

2025-04-28 18:04:04 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --usb off 
Exit Code: 0
Output:

2025-04-28 18:04:05 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-04-28 18:04:05 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-04-28 18:04:05 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --audio-enabled off 
Exit Code: 0
Output:

2025-04-28 18:04:05 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --clipboard disabled 
Exit Code: 0
Output:

2025-04-28 18:04:06 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --draganddrop disabled 
Exit Code: 0
Output:

2025-04-28 18:04:06 (16532): 
Command: VBoxManage -q storagectl "boinc_d0f263b104c82007" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-04-28 18:04:06 (16532): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:
UUID:           b1b25507-41e2-4ead-9ca8-6f5e1c8e2ce4
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       10240 MBytes
Size on disk:   2451 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-04-28 18:04:06 (16532): 
Command: VBoxManage -q storageattach "boinc_d0f263b104c82007" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-04-28 18:04:07 (16532): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:
UUID:           b1b25507-41e2-4ead-9ca8-6f5e1c8e2ce4
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       10240 MBytes
Size on disk:   2451 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-04-28 18:04:07 (16532): 
Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:

2025-04-28 18:04:07 (16532): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:
UUID:           b1b25507-41e2-4ead-9ca8-6f5e1c8e2ce4
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_04_17_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       10240 MBytes
Size on disk:   2451 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-04-28 18:04:08 (16532): 
Command: VBoxManage -q storageattach "boinc_d0f263b104c82007" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:

2025-04-28 18:04:08 (16532): 
Command: VBoxManage -q storageattach "boinc_d0f263b104c82007" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-04-28 18:04:08 (16532): 
Command: VBoxManage -q storageattach "boinc_d0f263b104c82007" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_04_17_prod.vdi" 
Exit Code: 0
Output:

2025-04-28 18:04:08 (16532): 
Command: VBoxManage -q storageattach "boinc_d0f263b104c82007" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-04-28 18:04:09 (16532): 
Command: VBoxManage -q bandwidthctl "boinc_d0f263b104c82007" add "boinc_d0f263b104c82007_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-04-28 18:04:09 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --natpf1 ",tcp,127.0.0.1,49982,,80" 
Exit Code: 0
Output:

2025-04-28 18:04:09 (16532): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:        7.0.4
Revision:       154605
Edition:        
Description:    Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption.
VRDE Module:    VBoxVRDP
Crypto Module:  VBoxPuelCrypto
Usable:         true
Why unusable:   

2025-04-28 18:04:10 (16532): 
Command: VBoxManage -q modifyvm "boinc_d0f263b104c82007" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 49983 --vrde-property "Security/Method=RDP" 
Exit Code: 0
Output:

2025-04-28 18:04:10 (16532): 
Command: VBoxManage -q sharedfolder add "boinc_d0f263b104c82007" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2025-04-28 18:04:14 (16532): 
Command: VBoxManage -q startvm "boinc_d0f263b104c82007" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Failed to launch the Remote Desktop Extension server (VERR_GENERAL_FAILURE)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_d0f263b104c82007" to power on...

2025-04-28 18:04:14 (16532): 
Command: VBoxManage -q snapshot "boinc_d0f263b104c82007" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-04-28 18:04:15 (16532): 
Command: VBoxManage -q bandwidthctl "boinc_d0f263b104c82007" remove "boinc_d0f263b104c82007_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2025-04-28 18:04:15 (16532): 
Command: VBoxManage -q unregistervm "boinc_d0f263b104c82007" --delete 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot unregister the machine 'boinc_d0f263b104c82007' while it is locked
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component MachineWrap, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "Unregister(fDeleteAll ? CleanupMode_DetachAllReturnHardDisksAndVMRemovable :CleanupMode_DetachAllReturnHardDisksOnly, ComSafeArrayAsOutParam(aMedia))" at line 236 of file VBoxManageMisc.cpp

2025-04-28 18:04:16 (16532): 
Command: VBoxManage -q unregistervm "boinc_d0f263b104c82007" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-04-28 18:04:26 (16532): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 CERN