Name CMS_3520235_1744800845.866446_0
Workunit 231655326
Created 16 Apr 2025, 10:54:08 UTC
Sent 16 Apr 2025, 11:24:00 UTC
Report deadline 17 May 2025, 11:24:00 UTC
Received 16 Apr 2025, 13:24:23 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10841864
Run time 22 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 17.73 GFLOPS
Application version CMS Simulation v70.91 (vbox64_mt_mcore_cms)
windows_x86_64
Peak working set size 5.21 MB
Peak swap size 2.25 MB
Peak disk usage 0.77 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2025-04-16 14:23:56 (1408): vboxwrapper version 26210
2025-04-16 14:23:56 (1408): BOINC client version: 8.0.2
2025-04-16 14:23:56 (1408): Detected: VirtualBox VboxManage Interface (Version: 7.0.24)
2025-04-16 14:23:57 (1408): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2025-04-16 14:23:57 (1408): Successfully copied 'init_data.xml' to the shared directory.
2025-04-16 14:23:57 (1408): Create VM. (boinc_dc568d1c8ceebde6, slot#0)
2025-04-16 14:23:58 (1408): Setting Memory Size for VM. (4584MB)
2025-04-16 14:23:58 (1408): Setting CPU Count for VM. (4)
2025-04-16 14:23:58 (1408): Setting Chipset Options for VM.
2025-04-16 14:23:58 (1408): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB)
2025-04-16 14:23:59 (1408): Setting Boot Options for VM.
2025-04-16 14:23:59 (1408): Setting Network Configuration for NAT. (Driver: virtio)
2025-04-16 14:23:59 (1408): Enabling VM Network Access.
2025-04-16 14:24:00 (1408): Disabling USB Support for VM.
2025-04-16 14:24:00 (1408): Disabling COM Port Support for VM.
2025-04-16 14:24:00 (1408): Disabling LPT Port Support for VM.
2025-04-16 14:24:00 (1408): Disabling Audio Support for VM.
2025-04-16 14:24:01 (1408): Disabling Clipboard Support for VM.
2025-04-16 14:24:01 (1408): Disabling Drag and Drop Support for VM.
2025-04-16 14:24:01 (1408): Adding storage controller(s) to VM.
2025-04-16 14:24:01 (1408): Adding virtual disk drive to VM. (CMS_2025_04_08_prod.vdi)
2025-04-16 14:24:03 (1408): Adding VirtualBox Guest Additions to VM.
2025-04-16 14:24:04 (1408): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-04-16 14:24:04 (1408): forwarding host port 58366 to guest port 80
2025-04-16 14:24:04 (1408): Enabling remote desktop for VM.
2025-04-16 14:24:05 (1408): Required extension pack not installed, remote desktop not enabled.
2025-04-16 14:24:05 (1408): Enabling shared directory for VM.
2025-04-16 14:24:05 (1408): Starting VM using VBoxManage interface. (boinc_dc568d1c8ceebde6, slot#0)
2025-04-16 14:24:09 (1408): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_dc568d1c8ceebde6" --type headless
Output:
VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_dc568d1c8ceebde6" to power on...

2025-04-16 14:24:09 (1408): VM failed to start.
2025-04-16 14:24:09 (1408): Could not start 
2025-04-16 14:24:09 (1408): ERROR: VM failed to start
2025-04-16 14:24:09 (1408): Powering off VM.
2025-04-16 14:24:09 (1408): Deregistering VM. (boinc_dc568d1c8ceebde6, slot#0)
2025-04-16 14:24:09 (1408): Removing network bandwidth throttle group from VM.
2025-04-16 14:24:09 (1408): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.474427          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.475427          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.477427          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.477427          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.477427          Saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.488428          Finished saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml"
00:00:07.488428          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.488428          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.489428          Saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.495428          Finished saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml"
00:00:07.495428          Saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox" with version "1.19-windows"
00:00:07.501429          Finished saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox"
00:00:07.737442          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.739442          Saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox" with version "1.19-windows"
00:00:07.744443          Finished saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox"
00:00:07.997457          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:08.000457          Saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox" with version "1.19-windows"
00:00:08.010458          Finished saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox"
00:00:08.516487          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:08.518487          Saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox" with version "1.19-windows"
00:00:08.526487          Finished saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox"
00:00:08.771501          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:08.773501          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:08.776502          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.777502          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.781502          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.029516          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:09.037516          Launched VM: 70253952 pid: 4308 (0x10d4) frontend: headless name: boinc_dc568d1c8ceebde6
00:00:12.864295          Saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox" with version "1.19-windows"
00:00:12.868796          Finished saving settings file "D:\BOINCdata\slots\0\boinc_dc568d1c8ceebde6\boinc_dc568d1c8ceebde6.vbox"
00:00:12.927803          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:12.928804          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.982310          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.240843          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:13.241343          ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_dc568d1c8ceebde6' while it is locked}, preserve=false aResultDetail=0
00:00:14.499419          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.500419          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:14.500419          Saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.512420          Finished saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml"
00:00:14.512420          Saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.520420          Finished saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml"
00:00:14.521420 DeleteVM Saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.527420 DeleteVM Finished saving settings file "C:\Users\Peter\.VirtualBox\VirtualBox.xml"
00:00:19.536707 main     VirtualBox: object deletion starts
00:00:19.537707 main     HostDnsMonitor: shutting down ...
00:00:19.537707 main     HostDnsMonitor: shut down
00:00:19.541707 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:19.541707 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

kbd"
uart1="off"
uart2="off"
uart3="off"
uart4="off"
lpt1="off"
lpt2="off"
audio="default"
audio_out="off"
audio_in="off"
clipboard="disabled"
draganddrop="disabled"
vrde="off"
usb="off"
ehci="off"
xhci="off"
recording_enabled="off"
recording_screens=1
 rec_screen0
rec_screen_enabled="on"
rec_screen_id=0
rec_screen_video_enabled="on"
rec_screen_audio_enabled="off"
rec_screen_dest="File"
rec_screen_dest_filename="D:\\BOINCdata\\slots\\0\\boinc_dc568d1c8ceebde6\\boinc_dc568d1c8ceebde6-screen0.webm"
rec_screen_opts="vc_enabled=true,ac_enabled=false,ac_profile=med"
rec_screen_video_res_xy="1024x768"
rec_screen_video_rate_kbps=512
rec_screen_video_fps=25
description="CMS_3520235_1744800845.866446_0"
GuestMemoryBalloon=0

2025-04-16 14:23:59 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on 
Exit Code: 0
Output:

2025-04-16 14:24:00 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --cable-connected1 on 
Exit Code: 0
Output:

2025-04-16 14:24:00 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --usb off 
Exit Code: 0
Output:

2025-04-16 14:24:00 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-04-16 14:24:00 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-04-16 14:24:01 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --audio-enabled off 
Exit Code: 0
Output:

2025-04-16 14:24:01 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --clipboard disabled 
Exit Code: 0
Output:

2025-04-16 14:24:01 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --draganddrop disabled 
Exit Code: 0
Output:

2025-04-16 14:24:01 (1408): 
Command: VBoxManage -q storagectl "boinc_dc568d1c8ceebde6" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-04-16 14:24:02 (1408): 
Command: VBoxManage -q showhdinfo "D:\BOINCdata/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" 
Exit Code: 0
Output:
UUID:           fa49c4e2-ad29-47a5-b96a-3c89ce80d84c
Parent UUID:    base
State:          created
Type:           multiattach
Location:       D:\BOINCdata\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-04-16 14:24:02 (1408): 
Command: VBoxManage -q storageattach "boinc_dc568d1c8ceebde6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "D:\BOINCdata/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'D:\BOINCdata\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-04-16 14:24:02 (1408): 
Command: VBoxManage -q showhdinfo "D:\BOINCdata/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" 
Exit Code: 0
Output:
UUID:           fa49c4e2-ad29-47a5-b96a-3c89ce80d84c
Parent UUID:    base
State:          created
Type:           multiattach
Location:       D:\BOINCdata\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-04-16 14:24:02 (1408): 
Command: VBoxManage -q closemedium disk "D:\BOINCdata\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi" 
Exit Code: 0
Output:

2025-04-16 14:24:03 (1408): 
Command: VBoxManage -q showhdinfo "D:\BOINCdata/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" 
Exit Code: 0
Output:
UUID:           fa49c4e2-ad29-47a5-b96a-3c89ce80d84c
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       D:\BOINCdata\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-04-16 14:24:03 (1408): 
Command: VBoxManage -q storageattach "boinc_dc568d1c8ceebde6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "D:\BOINCdata/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" 
Exit Code: 0
Output:

2025-04-16 14:24:03 (1408): 
Command: VBoxManage -q storageattach "boinc_dc568d1c8ceebde6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-04-16 14:24:03 (1408): 
Command: VBoxManage -q storageattach "boinc_dc568d1c8ceebde6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "D:\BOINCdata/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" 
Exit Code: 0
Output:

2025-04-16 14:24:04 (1408): 
Command: VBoxManage -q storageattach "boinc_dc568d1c8ceebde6" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-04-16 14:24:04 (1408): 
Command: VBoxManage -q bandwidthctl "boinc_dc568d1c8ceebde6" add "boinc_dc568d1c8ceebde6_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-04-16 14:24:04 (1408): 
Command: VBoxManage -q modifyvm "boinc_dc568d1c8ceebde6" --natpf1 ",tcp,127.0.0.1,58366,,80" 
Exit Code: 0
Output:

2025-04-16 14:24:05 (1408): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-04-16 14:24:05 (1408): 
Command: VBoxManage -q sharedfolder add "boinc_dc568d1c8ceebde6" --name "shared" --hostpath "D:\BOINCdata\slots\0/shared"
Exit Code: 0
Output:

2025-04-16 14:24:09 (1408): 
Command: VBoxManage -q startvm "boinc_dc568d1c8ceebde6" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_dc568d1c8ceebde6" to power on...

2025-04-16 14:24:09 (1408): 
Command: VBoxManage -q snapshot "boinc_dc568d1c8ceebde6" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-04-16 14:24:09 (1408): 
Command: VBoxManage -q bandwidthctl "boinc_dc568d1c8ceebde6" remove "boinc_dc568d1c8ceebde6_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2025-04-16 14:24:09 (1408): 
Command: VBoxManage -q unregistervm "boinc_dc568d1c8ceebde6" --delete 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot unregister the machine 'boinc_dc568d1c8ceebde6' while it is locked
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component MachineWrap, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "Unregister(fDeleteAll ? CleanupMode_DetachAllReturnHardDisksAndVMRemovable :CleanupMode_DetachAllReturnHardDisksOnly, ComSafeArrayAsOutParam(aMedia))" at line 236 of file VBoxManageMisc.cpp

2025-04-16 14:24:11 (1408): 
Command: VBoxManage -q unregistervm "boinc_dc568d1c8ceebde6" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-04-16 14:24:16 (1408): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 CERN