Name | KviMDmXf8N7nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmdYTLDm3STPnn_0 |
Workunit | 231583663 |
Created | 13 Apr 2025, 9:19:00 UTC |
Sent | 13 Apr 2025, 12:33:42 UTC |
Report deadline | 21 Apr 2025, 12:33:42 UTC |
Received | 13 Apr 2025, 14:10:06 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10872228 |
Run time | 20 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 8.45 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.52 MB |
Peak swap size | 2.10 MB |
Peak disk usage | 210.53 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-04-13 09:09:10 (71420): Detected: vboxwrapper 26206 2025-04-13 09:09:10 (71420): Detected: BOINC client v8.0.2 2025-04-13 09:09:11 (71420): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-04-13 09:09:11 (71420): Successfully copied 'init_data.xml' to the shared directory. 2025-04-13 09:09:12 (71420): Create VM. (boinc_c495c28fb1dc26db, slot#3) 2025-04-13 09:09:12 (71420): Setting Memory Size for VM. (4200MB) 2025-04-13 09:09:12 (71420): Setting CPU Count for VM. (2) 2025-04-13 09:09:13 (71420): Setting Chipset Options for VM. 2025-04-13 09:09:13 (71420): Setting Graphics Controller Options for VM. 2025-04-13 09:09:13 (71420): Setting Boot Options for VM. 2025-04-13 09:09:13 (71420): Setting Network Configuration for NAT. 2025-04-13 09:09:14 (71420): Enabling VM Network Access. 2025-04-13 09:09:14 (71420): Disabling USB Support for VM. 2025-04-13 09:09:15 (71420): Disabling COM Port Support for VM. 2025-04-13 09:09:15 (71420): Disabling LPT Port Support for VM. 2025-04-13 09:09:15 (71420): Disabling Audio Support for VM. 2025-04-13 09:09:15 (71420): Disabling Clipboard Support for VM. 2025-04-13 09:09:16 (71420): Disabling Drag and Drop Support for VM. 2025-04-13 09:09:16 (71420): Adding storage controller(s) to VM. 2025-04-13 09:09:16 (71420): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-04-13 09:09:19 (71420): Adding VirtualBox Guest Additions to VM. 2025-04-13 09:09:19 (71420): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-04-13 09:09:20 (71420): forwarding host port 60839 to guest port 80 2025-04-13 09:09:20 (71420): Enabling remote desktop for VM. 2025-04-13 09:09:20 (71420): Required extension pack not installed, remote desktop not enabled. 2025-04-13 09:09:20 (71420): Enabling shared directory for VM. 2025-04-13 09:09:21 (71420): Starting VM using VBoxManage interface. (boinc_c495c28fb1dc26db, slot#3) 2025-04-13 09:09:22 (71420): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_c495c28fb1dc26db" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_c495c28fb1dc26db' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_c495c28fb1dc26db" to power on... 2025-04-13 09:09:22 (71420): VM failed to start. 2025-04-13 09:09:22 (71420): Could not start 2025-04-13 09:09:22 (71420): ERROR: VM failed to start 2025-04-13 09:09:22 (71420): Powering off VM. 2025-04-13 09:09:22 (71420): Deregistering VM. (boinc_c495c28fb1dc26db, slot#3) 2025-04-13 09:09:22 (71420): Removing network bandwidth throttle group from VM. 2025-04-13 09:09:22 (71420): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.461274 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.461553 Saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.471846 Finished saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" 00:00:08.472751 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:08.481211 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:08.736348 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:08.745279 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:09.000237 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.001190 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:09.010706 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:09.011168 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.016402 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:09.024953 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:09.026771 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:09.036272 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:09.270358 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.273874 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.274196 Saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.280211 Finished saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" 00:00:09.281232 Saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.289075 Finished saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" 00:00:09.290061 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:09.300100 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:09.539913 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:09.554344 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:09.814881 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:09.828536 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:10.349212 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:10.359380 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:10.614073 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.628234 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.628421 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.642848 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.880567 Launched VM: 1215345616 pid: 67956 (0x10974) frontend: headless name: boinc_c495c28fb1dc26db 00:00:11.638497 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_c495c28fb1dc26db' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.639490 Watcher Reaper: Pid 67956 (0x10974) exited normally: 1 (0x1) 00:00:11.753508 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.842777 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" with version "1.19-windows" 00:00:11.856376 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox" 00:00:12.116971 Saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.127534 Finished saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" 00:00:12.127713 Saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.132424 Finished saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" 00:00:12.134259 DeleteVM Saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.141095 DeleteVM Finished saving settings file "C:\Users\kennl\.VirtualBox\VirtualBox.xml" 00:00:17.164558 main VirtualBox: object deletion starts 00:00:17.165566 main HostDnsMonitor: shutting down ... 00:00:17.165619 main HostDnsMonitor: shut down 00:00:17.167585 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:17.167842 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\3/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-04-13 09:09:12 (71420): Command: VBoxManage -q createvm --name "boinc_c495c28fb1dc26db" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_c495c28fb1dc26db' is created and registered. UUID: fd3dc1c5-1901-4a95-963a-dc81040dbcd6 Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\boinc_c495c28fb1dc26db.vbox' 2025-04-13 09:09:12 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --description "KviMDmXf8N7nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmdYTLDm3STPnn_0" Exit Code: 0 Output: 2025-04-13 09:09:12 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --memory 4200 Exit Code: 0 Output: 2025-04-13 09:09:13 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --cpus 2 Exit Code: 0 Output: 2025-04-13 09:09:13 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-04-13 09:09:13 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-04-13 09:09:13 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-04-13 09:09:14 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-04-13 09:09:14 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --cableconnected1 on Exit Code: 0 Output: 2025-04-13 09:09:15 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --usb off Exit Code: 0 Output: 2025-04-13 09:09:15 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --uart1 off --uart2 off Exit Code: 0 Output: 2025-04-13 09:09:15 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-04-13 09:09:15 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-04-13 09:09:16 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --clipboard disabled Exit Code: 0 Output: 2025-04-13 09:09:16 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --draganddrop disabled Exit Code: 0 Output: 2025-04-13 09:09:16 (71420): Command: VBoxManage -q storagectl "boinc_c495c28fb1dc26db" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-04-13 09:09:17 (71420): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-04-13 09:09:17 (71420): Command: VBoxManage -q storageattach "boinc_c495c28fb1dc26db" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-04-13 09:09:17 (71420): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-04-13 09:09:18 (71420): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-04-13 09:09:19 (71420): Command: VBoxManage -q storageattach "boinc_c495c28fb1dc26db" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-04-13 09:09:19 (71420): Command: VBoxManage -q storageattach "boinc_c495c28fb1dc26db" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-04-13 09:09:19 (71420): Command: VBoxManage -q storageattach "boinc_c495c28fb1dc26db" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-04-13 09:09:19 (71420): Command: VBoxManage -q storageattach "boinc_c495c28fb1dc26db" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-04-13 09:09:20 (71420): Command: VBoxManage -q bandwidthctl "boinc_c495c28fb1dc26db" add "boinc_c495c28fb1dc26db_net" --type network --limit 1024G Exit Code: 0 Output: 2025-04-13 09:09:20 (71420): Command: VBoxManage -q modifyvm "boinc_c495c28fb1dc26db" --natpf1 ",tcp,127.0.0.1,60839,,80" Exit Code: 0 Output: 2025-04-13 09:09:20 (71420): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-04-13 09:09:21 (71420): Command: VBoxManage -q sharedfolder add "boinc_c495c28fb1dc26db" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared" Exit Code: 0 Output: 2025-04-13 09:09:22 (71420): Command: VBoxManage -q startvm "boinc_c495c28fb1dc26db" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_c495c28fb1dc26db' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_c495c28fb1dc26db\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_c495c28fb1dc26db" to power on... 2025-04-13 09:09:22 (71420): Command: VBoxManage -q snapshot "boinc_c495c28fb1dc26db" list Exit Code: -108 Output: This machine does not have any snapshots 2025-04-13 09:09:22 (71420): Command: VBoxManage -q bandwidthctl "boinc_c495c28fb1dc26db" remove "boinc_c495c28fb1dc26db_net" Exit Code: 0 Output: 2025-04-13 09:09:22 (71420): Command: VBoxManage -q unregistervm "boinc_c495c28fb1dc26db" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 09:09:28 (71420): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN