Name | fdQLDmXJHK7nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmgqFLDmHxWonn_0 |
Workunit | 231328842 |
Created | 2 Apr 2025, 17:44:22 UTC |
Sent | 2 Apr 2025, 22:48:46 UTC |
Report deadline | 10 Apr 2025, 22:48:46 UTC |
Received | 3 Apr 2025, 8:43:42 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10848193 |
Run time | 5 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 37.24 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.74 MB |
Peak swap size | 2.15 MB |
Peak disk usage | 212.15 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Fonction incorrecte. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-04-03 01:05:11 (45788): Detected: vboxwrapper 26206 2025-04-03 01:05:11 (45788): Detected: BOINC client v8.0.2 2025-04-03 01:05:12 (45788): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-04-03 01:05:12 (45788): Successfully copied 'init_data.xml' to the shared directory. 2025-04-03 01:05:12 (45788): Create VM. (boinc_a64285312ffe8ef3, slot#0) 2025-04-03 01:05:13 (45788): Setting Memory Size for VM. (4800MB) 2025-04-03 01:05:13 (45788): Setting CPU Count for VM. (8) 2025-04-03 01:05:14 (45788): Setting Chipset Options for VM. 2025-04-03 01:05:14 (45788): Setting Graphics Controller Options for VM. 2025-04-03 01:05:14 (45788): Setting Boot Options for VM. 2025-04-03 01:05:14 (45788): Setting Network Configuration for NAT. 2025-04-03 01:05:15 (45788): Enabling VM Network Access. 2025-04-03 01:05:15 (45788): Disabling USB Support for VM. 2025-04-03 01:05:15 (45788): Disabling COM Port Support for VM. 2025-04-03 01:05:16 (45788): Disabling LPT Port Support for VM. 2025-04-03 01:05:16 (45788): Disabling Audio Support for VM. 2025-04-03 01:05:16 (45788): Disabling Clipboard Support for VM. 2025-04-03 01:05:16 (45788): Disabling Drag and Drop Support for VM. 2025-04-03 01:05:17 (45788): Adding storage controller(s) to VM. 2025-04-03 01:05:17 (45788): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-04-03 01:05:20 (45788): Adding VirtualBox Guest Additions to VM. 2025-04-03 01:05:20 (45788): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-04-03 01:05:20 (45788): forwarding host port 28297 to guest port 80 2025-04-03 01:05:21 (45788): Enabling remote desktop for VM. 2025-04-03 01:05:21 (45788): Required extension pack not installed, remote desktop not enabled. 2025-04-03 01:05:21 (45788): Enabling shared directory for VM. 2025-04-03 01:05:22 (45788): Starting VM using VBoxManage interface. (boinc_a64285312ffe8ef3, slot#0) 2025-04-03 01:05:22 (45788): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_a64285312ffe8ef3" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_a64285312ffe8ef3' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_a64285312ffe8ef3" to power on... 2025-04-03 01:05:22 (45788): VM failed to start. 2025-04-03 01:05:22 (45788): Could not start 2025-04-03 01:05:22 (45788): ERROR: VM failed to start 2025-04-03 01:05:22 (45788): Powering off VM. 2025-04-03 01:05:22 (45788): Deregistering VM. (boinc_a64285312ffe8ef3, slot#0) 2025-04-03 01:05:22 (45788): Removing network bandwidth throttle group from VM. 2025-04-03 01:05:23 (45788): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.124504 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.124719 Saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.130731 Finished saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" 00:00:08.131194 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:08.136862 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:08.406073 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:08.411793 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:08.677793 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.678425 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:08.683326 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:08.683566 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.688322 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:08.693008 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:08.693534 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:08.698432 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:08.960146 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.962499 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.962748 Saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.969831 Finished saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" 00:00:08.970221 Saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.976000 Finished saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" 00:00:08.976430 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:08.981612 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:09.231129 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:09.236397 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:09.511364 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:09.516570 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:10.068202 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:10.073726 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:10.348767 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.354907 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.355029 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.361597 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.645524 Launched VM: 3820608768 pid: 32072 (0x7d48) frontend: headless name: boinc_a64285312ffe8ef3 00:00:11.209714 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_a64285312ffe8ef3' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.210257 Watcher Reaper: Pid 32072 (0x7d48) exited normally: 1 (0x1) 00:00:11.307065 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.381523 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" with version "1.19-windows" 00:00:11.386732 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox" 00:00:11.650646 Saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.657391 Finished saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" 00:00:11.657563 Saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.664592 Finished saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" 00:00:11.665839 DeleteVM Saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.672676 DeleteVM Finished saving settings file "C:\Users\moloc\.VirtualBox\VirtualBox.xml" 00:00:16.687162 main VirtualBox: object deletion starts 00:00:16.688426 main HostDnsMonitor: shutting down ... 00:00:16.688518 main HostDnsMonitor: shut down 00:00:16.690304 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.690848 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-04-03 01:05:13 (45788): Command: VBoxManage -q createvm --name "boinc_a64285312ffe8ef3" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_a64285312ffe8ef3' is created and registered. UUID: 2c1c1cef-3e65-4ad8-abdf-807dd75621cd Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\boinc_a64285312ffe8ef3.vbox' 2025-04-03 01:05:13 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --description "fdQLDmXJHK7nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmgqFLDmHxWonn_0" Exit Code: 0 Output: 2025-04-03 01:05:13 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --memory 4800 Exit Code: 0 Output: 2025-04-03 01:05:14 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --cpus 8 Exit Code: 0 Output: 2025-04-03 01:05:14 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-04-03 01:05:14 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-04-03 01:05:14 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-04-03 01:05:15 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-04-03 01:05:15 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --cableconnected1 on Exit Code: 0 Output: 2025-04-03 01:05:15 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --usb off Exit Code: 0 Output: 2025-04-03 01:05:16 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --uart1 off --uart2 off Exit Code: 0 Output: 2025-04-03 01:05:16 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-04-03 01:05:16 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-04-03 01:05:16 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --clipboard disabled Exit Code: 0 Output: 2025-04-03 01:05:17 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --draganddrop disabled Exit Code: 0 Output: 2025-04-03 01:05:17 (45788): Command: VBoxManage -q storagectl "boinc_a64285312ffe8ef3" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-04-03 01:05:17 (45788): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-04-03 01:05:17 (45788): Command: VBoxManage -q storageattach "boinc_a64285312ffe8ef3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-04-03 01:05:18 (45788): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-04-03 01:05:19 (45788): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-04-03 01:05:19 (45788): Command: VBoxManage -q storageattach "boinc_a64285312ffe8ef3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-04-03 01:05:20 (45788): Command: VBoxManage -q storageattach "boinc_a64285312ffe8ef3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-04-03 01:05:20 (45788): Command: VBoxManage -q storageattach "boinc_a64285312ffe8ef3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-04-03 01:05:20 (45788): Command: VBoxManage -q storageattach "boinc_a64285312ffe8ef3" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-04-03 01:05:20 (45788): Command: VBoxManage -q bandwidthctl "boinc_a64285312ffe8ef3" add "boinc_a64285312ffe8ef3_net" --type network --limit 1024G Exit Code: 0 Output: 2025-04-03 01:05:21 (45788): Command: VBoxManage -q modifyvm "boinc_a64285312ffe8ef3" --natpf1 ",tcp,127.0.0.1,28297,,80" Exit Code: 0 Output: 2025-04-03 01:05:21 (45788): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-04-03 01:05:21 (45788): Command: VBoxManage -q sharedfolder add "boinc_a64285312ffe8ef3" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-04-03 01:05:22 (45788): Command: VBoxManage -q startvm "boinc_a64285312ffe8ef3" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_a64285312ffe8ef3' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_a64285312ffe8ef3\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_a64285312ffe8ef3" to power on... 2025-04-03 01:05:22 (45788): Command: VBoxManage -q snapshot "boinc_a64285312ffe8ef3" list Exit Code: -108 Output: This machine does not have any snapshots 2025-04-03 01:05:23 (45788): Command: VBoxManage -q bandwidthctl "boinc_a64285312ffe8ef3" remove "boinc_a64285312ffe8ef3_net" Exit Code: 0 Output: 2025-04-03 01:05:23 (45788): Command: VBoxManage -q unregistervm "boinc_a64285312ffe8ef3" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 01:05:28 (45788): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN