Name | GuzNDmtUTJ7n9Rq4apOajLDm4fhM0noT9bVoFjIUDmIvpKDmAX7zxn_0 |
Workunit | 231251388 |
Created | 31 Mar 2025, 12:33:03 UTC |
Sent | 31 Mar 2025, 13:58:43 UTC |
Report deadline | 8 Apr 2025, 13:58:43 UTC |
Received | 31 Mar 2025, 14:03:58 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10869903 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 40.12 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 9.06 MB |
Peak swap size | 2.11 MB |
Peak disk usage | 328.58 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Nespr�vn� funkce. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-03-31 16:01:04 (19052): Detected: vboxwrapper 26206 2025-03-31 16:01:04 (19052): Detected: BOINC client v8.0.2 2025-03-31 16:01:04 (19052): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-03-31 16:01:05 (19052): Successfully copied 'init_data.xml' to the shared directory. 2025-03-31 16:01:05 (19052): Create VM. (boinc_2cea64dbd03de1ea, slot#0) 2025-03-31 16:01:06 (19052): Setting Memory Size for VM. (4800MB) 2025-03-31 16:01:06 (19052): Setting CPU Count for VM. (8) 2025-03-31 16:01:06 (19052): Setting Chipset Options for VM. 2025-03-31 16:01:06 (19052): Setting Graphics Controller Options for VM. 2025-03-31 16:01:07 (19052): Setting Boot Options for VM. 2025-03-31 16:01:07 (19052): Setting Network Configuration for NAT. 2025-03-31 16:01:07 (19052): Enabling VM Network Access. 2025-03-31 16:01:07 (19052): Disabling USB Support for VM. 2025-03-31 16:01:08 (19052): Disabling COM Port Support for VM. 2025-03-31 16:01:08 (19052): Disabling LPT Port Support for VM. 2025-03-31 16:01:08 (19052): Disabling Audio Support for VM. 2025-03-31 16:01:09 (19052): Disabling Clipboard Support for VM. 2025-03-31 16:01:09 (19052): Disabling Drag and Drop Support for VM. 2025-03-31 16:01:09 (19052): Adding storage controller(s) to VM. 2025-03-31 16:01:09 (19052): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-03-31 16:01:12 (19052): Adding VirtualBox Guest Additions to VM. 2025-03-31 16:01:13 (19052): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-03-31 16:01:13 (19052): forwarding host port 49712 to guest port 80 2025-03-31 16:01:13 (19052): Enabling remote desktop for VM. 2025-03-31 16:01:13 (19052): Required extension pack not installed, remote desktop not enabled. 2025-03-31 16:01:13 (19052): Enabling shared directory for VM. 2025-03-31 16:01:14 (19052): Starting VM using VBoxManage interface. (boinc_2cea64dbd03de1ea, slot#0) 2025-03-31 16:01:14 (19052): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_2cea64dbd03de1ea" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_2cea64dbd03de1ea' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_2cea64dbd03de1ea" to power on... 2025-03-31 16:01:14 (19052): VM failed to start. 2025-03-31 16:01:14 (19052): Could not start 2025-03-31 16:01:14 (19052): ERROR: VM failed to start 2025-03-31 16:01:14 (19052): Powering off VM. 2025-03-31 16:01:14 (19052): Deregistering VM. (boinc_2cea64dbd03de1ea, slot#0) 2025-03-31 16:01:14 (19052): Removing network bandwidth throttle group from VM. 2025-03-31 16:01:15 (19052): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.384726 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.384868 Saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.390525 Finished saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" 00:00:07.390863 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:07.395499 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:07.670708 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:07.678770 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:07.932767 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.933230 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:07.939230 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:07.939356 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.940785 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:07.945678 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:07.946132 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:07.951468 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:08.202682 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.204160 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.204327 Saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.210951 Finished saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" 00:00:08.211247 Saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.216362 Finished saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" 00:00:08.216805 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:08.222377 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:08.511552 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:08.518737 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:08.749295 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:08.754786 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:09.277192 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:09.284235 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:09.562070 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.568028 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.568096 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.575092 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.838904 Launched VM: 467878704 pid: 11100 (0x2b5c) frontend: headless name: boinc_2cea64dbd03de1ea 00:00:10.227263 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_2cea64dbd03de1ea' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.228257 Watcher Reaper: Pid 11100 (0x2b5c) exited normally: 1 (0x1) 00:00:10.300355 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.344840 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" with version "1.19-windows" 00:00:10.351959 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox" 00:00:10.691579 Saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.697816 Finished saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" 00:00:10.697953 Saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.702878 Finished saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" 00:00:10.703636 DeleteVM Saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.708338 DeleteVM Finished saving settings file "C:\Users\anton\.VirtualBox\VirtualBox.xml" 00:00:15.725731 main VirtualBox: object deletion starts 00:00:15.726583 main HostDnsMonitor: shutting down ... 00:00:15.726612 main HostDnsMonitor: shut down 00:00:15.728697 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.728899 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-03-31 16:01:05 (19052): Command: VBoxManage -q createvm --name "boinc_2cea64dbd03de1ea" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_2cea64dbd03de1ea' is created and registered. UUID: 481bc30d-51a8-4fb5-b1ee-7fc6770c511b Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\boinc_2cea64dbd03de1ea.vbox' 2025-03-31 16:01:06 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --description "GuzNDmtUTJ7n9Rq4apOajLDm4fhM0noT9bVoFjIUDmIvpKDmAX7zxn_0" Exit Code: 0 Output: 2025-03-31 16:01:06 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --memory 4800 Exit Code: 0 Output: 2025-03-31 16:01:06 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --cpus 8 Exit Code: 0 Output: 2025-03-31 16:01:06 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-03-31 16:01:07 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-03-31 16:01:07 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-03-31 16:01:07 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-03-31 16:01:07 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --cableconnected1 on Exit Code: 0 Output: 2025-03-31 16:01:08 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --usb off Exit Code: 0 Output: 2025-03-31 16:01:08 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --uart1 off --uart2 off Exit Code: 0 Output: 2025-03-31 16:01:08 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-03-31 16:01:09 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-03-31 16:01:09 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --clipboard disabled Exit Code: 0 Output: 2025-03-31 16:01:09 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --draganddrop disabled Exit Code: 0 Output: 2025-03-31 16:01:09 (19052): Command: VBoxManage -q storagectl "boinc_2cea64dbd03de1ea" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-03-31 16:01:10 (19052): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-03-31 16:01:10 (19052): Command: VBoxManage -q storageattach "boinc_2cea64dbd03de1ea" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-03-31 16:01:10 (19052): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-03-31 16:01:11 (19052): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-03-31 16:01:12 (19052): Command: VBoxManage -q storageattach "boinc_2cea64dbd03de1ea" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-03-31 16:01:12 (19052): Command: VBoxManage -q storageattach "boinc_2cea64dbd03de1ea" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-03-31 16:01:12 (19052): Command: VBoxManage -q storageattach "boinc_2cea64dbd03de1ea" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-03-31 16:01:13 (19052): Command: VBoxManage -q storageattach "boinc_2cea64dbd03de1ea" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-03-31 16:01:13 (19052): Command: VBoxManage -q bandwidthctl "boinc_2cea64dbd03de1ea" add "boinc_2cea64dbd03de1ea_net" --type network --limit 1024G Exit Code: 0 Output: 2025-03-31 16:01:13 (19052): Command: VBoxManage -q modifyvm "boinc_2cea64dbd03de1ea" --natpf1 ",tcp,127.0.0.1,49712,,80" Exit Code: 0 Output: 2025-03-31 16:01:13 (19052): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-03-31 16:01:14 (19052): Command: VBoxManage -q sharedfolder add "boinc_2cea64dbd03de1ea" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-03-31 16:01:14 (19052): Command: VBoxManage -q startvm "boinc_2cea64dbd03de1ea" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_2cea64dbd03de1ea' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_2cea64dbd03de1ea\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_2cea64dbd03de1ea" to power on... 2025-03-31 16:01:14 (19052): Command: VBoxManage -q snapshot "boinc_2cea64dbd03de1ea" list Exit Code: -108 Output: This machine does not have any snapshots 2025-03-31 16:01:15 (19052): Command: VBoxManage -q bandwidthctl "boinc_2cea64dbd03de1ea" remove "boinc_2cea64dbd03de1ea_net" Exit Code: 0 Output: 2025-03-31 16:01:15 (19052): Command: VBoxManage -q unregistervm "boinc_2cea64dbd03de1ea" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 16:01:20 (19052): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN