Name | CMS_3515150_1741650265.421197_0 |
Workunit | 230774041 |
Created | 10 Mar 2025, 23:44:30 UTC |
Sent | 11 Mar 2025, 2:30:56 UTC |
Report deadline | 11 Apr 2025, 2:30:56 UTC |
Received | 11 Mar 2025, 3:22:11 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10844799 |
Run time | 1 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 16.93 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 10.19 MB |
Peak swap size | 4.50 MB |
Peak disk usage | 0.76 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-03-10 23:18:14 (7960): vboxwrapper version 26208 2025-03-10 23:18:14 (7960): BOINC client version: 8.0.2 2025-03-10 23:18:15 (7960): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2025-03-10 23:18:16 (7960): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-03-10 23:18:16 (7960): Successfully copied 'init_data.xml' to the shared directory. 2025-03-10 23:18:16 (7960): Create VM. (boinc_42203b2779638152, slot#5) 2025-03-10 23:18:16 (7960): Setting Memory Size for VM. (4584MB) 2025-03-10 23:18:17 (7960): Setting CPU Count for VM. (4) 2025-03-10 23:18:17 (7960): Setting Chipset Options for VM. 2025-03-10 23:18:17 (7960): Setting Graphics Controller Options for VM. 2025-03-10 23:18:17 (7960): Setting Boot Options for VM. 2025-03-10 23:18:18 (7960): Setting Network Configuration for NAT. 2025-03-10 23:18:18 (7960): Enabling VM Network Access. 2025-03-10 23:18:18 (7960): Disabling USB Support for VM. 2025-03-10 23:18:19 (7960): Disabling COM Port Support for VM. 2025-03-10 23:18:19 (7960): Disabling LPT Port Support for VM. 2025-03-10 23:18:19 (7960): Disabling Audio Support for VM. 2025-03-10 23:18:20 (7960): Disabling Clipboard Support for VM. 2025-03-10 23:18:20 (7960): Disabling Drag and Drop Support for VM. 2025-03-10 23:18:20 (7960): Adding storage controller(s) to VM. 2025-03-10 23:18:20 (7960): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-03-10 23:18:21 (7960): Adding VirtualBox Guest Additions to VM. 2025-03-10 23:18:22 (7960): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-03-10 23:18:22 (7960): forwarding host port 49571 to guest port 80 2025-03-10 23:18:22 (7960): Enabling remote desktop for VM. 2025-03-10 23:18:22 (7960): Required extension pack not installed, remote desktop not enabled. 2025-03-10 23:18:22 (7960): Enabling shared directory for VM. 2025-03-10 23:18:23 (7960): Starting VM using VBoxManage interface. (boinc_42203b2779638152, slot#5) 2025-03-10 23:18:27 (7960): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_42203b2779638152" --type headless Output: Waiting for VM "boinc_42203b2779638152" to power on... VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2025-03-10 23:18:27 (7960): VM failed to start. 2025-03-10 23:18:27 (7960): Could not start 2025-03-10 23:18:27 (7960): ERROR: VM failed to start 2025-03-10 23:18:27 (7960): Powering off VM. 2025-03-10 23:18:27 (7960): Deregistering VM. (boinc_42203b2779638152, slot#5) 2025-03-10 23:18:27 (7960): Removing network bandwidth throttle group from VM. 2025-03-10 23:18:28 (7960): Removing VM from VirtualBox. Hypervisor System Log: 00:00:01.431199 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:01.690615 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:01.953115 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:02.218189 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:02.477936 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:03.065112 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:03.253795 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:03.522767 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:03.774051 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:04.041387 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:04.298066 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:04.558300 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:04.820552 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:05.084068 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:05.347482 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:05.867533 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.868534 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.868534 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.875587 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:06.129427 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:06.390317 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.390843 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:06.395932 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.398930 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:06.402575 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:06.652554 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.653555 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.653555 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.659605 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.666188 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:06.920039 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:07.179085 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:07.703369 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:08.295323 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.295323 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.300332 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.484002 Launched VM: 84762864 pid: 6568 (0x19a8) frontend: headless name: boinc_42203b2779638152 00:00:12.559882 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:12.682025 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:13.112929 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox" with version "1.16-windows" 00:00:13.290271 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:18.303365 main VirtualBox: object deletion starts 00:00:18.304367 main HostDnsMonitor: shutting down ... 00:00:18.304367 main HostDnsMonitor: shut down 00:00:18.305368 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:18.305368 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: tPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: E:\ProgramFiles/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2025-03-10 23:18:16 (7960): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2025-03-11T03:18:15.916000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Memory size: 10195 MByte Memory available: 2997 MByte Operating system: Windows 8.1 Operating system version: 6.3.9600 2025-03-10 23:18:16 (7960): Command: VBoxManage -q showvminfo "boinc_42203b2779638152" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_42203b2779638152' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2025-03-10 23:18:16 (7960): Command: VBoxManage -q createvm --name "boinc_42203b2779638152" --basefolder "E:\ProgramFiles\BOINC\DataFiles\slots\5" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_42203b2779638152' is created and registered. UUID: 0021051c-fe4c-4eab-a778-a432312474e3 Settings file: 'E:\ProgramFiles\BOINC\DataFiles\slots\5\boinc_42203b2779638152\boinc_42203b2779638152.vbox' 2025-03-10 23:18:16 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --description "CMS_3515150_1741650265.421197_0" Exit Code: 0 Output: 2025-03-10 23:18:17 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --memory 4584 Exit Code: 0 Output: 2025-03-10 23:18:17 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --cpus 4 Exit Code: 0 Output: 2025-03-10 23:18:17 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-03-10 23:18:17 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-03-10 23:18:18 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-03-10 23:18:18 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-03-10 23:18:18 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --cableconnected1 on Exit Code: 0 Output: 2025-03-10 23:18:19 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --usb off Exit Code: 0 Output: 2025-03-10 23:18:19 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --uart1 off --uart2 off Exit Code: 0 Output: 2025-03-10 23:18:19 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-03-10 23:18:20 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --audio none Exit Code: 0 Output: 2025-03-10 23:18:20 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --clipboard disabled Exit Code: 0 Output: 2025-03-10 23:18:20 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --draganddrop disabled Exit Code: 0 Output: 2025-03-10 23:18:20 (7960): Command: VBoxManage -q storagectl "boinc_42203b2779638152" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-03-10 23:18:21 (7960): Command: VBoxManage -q showhdinfo "E:\ProgramFiles\BOINC\DataFiles/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: E:\ProgramFiles\BOINC\DataFiles\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-03-10 23:18:21 (7960): Command: VBoxManage -q storageattach "boinc_42203b2779638152" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "E:\ProgramFiles\BOINC\DataFiles/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-03-10 23:18:21 (7960): Command: VBoxManage -q storageattach "boinc_42203b2779638152" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-03-10 23:18:21 (7960): Command: VBoxManage -q storageattach "boinc_42203b2779638152" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\ProgramFiles\BOINC\DataFiles/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-03-10 23:18:22 (7960): Command: VBoxManage -q storageattach "boinc_42203b2779638152" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "E:\ProgramFiles/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-03-10 23:18:22 (7960): Command: VBoxManage -q bandwidthctl "boinc_42203b2779638152" add "boinc_42203b2779638152_net" --type network --limit 1024G Exit Code: 0 Output: 2025-03-10 23:18:22 (7960): Command: VBoxManage -q modifyvm "boinc_42203b2779638152" --natpf1 ",tcp,127.0.0.1,49571,,80" Exit Code: 0 Output: 2025-03-10 23:18:22 (7960): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-03-10 23:18:23 (7960): Command: VBoxManage -q sharedfolder add "boinc_42203b2779638152" --name "shared" --hostpath "E:\ProgramFiles\BOINC\DataFiles\slots\5/shared" Exit Code: 0 Output: 2025-03-10 23:18:27 (7960): Command: VBoxManage -q startvm "boinc_42203b2779638152" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_42203b2779638152" to power on... VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2025-03-10 23:18:27 (7960): Command: VBoxManage -q snapshot "boinc_42203b2779638152" list Exit Code: -108 Output: This machine does not have any snapshots 2025-03-10 23:18:28 (7960): Command: VBoxManage -q bandwidthctl "boinc_42203b2779638152" remove "boinc_42203b2779638152_net" Exit Code: 0 Output: 2025-03-10 23:18:28 (7960): Command: VBoxManage -q unregistervm "boinc_42203b2779638152" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-03-10 23:18:33 (7960): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN