Name | BdnLDmVWI76nsSi4ap6QjLDmwznN0nGgGQJmkKkKDm3HxKDmx0i5pn_0 |
Workunit | 230561948 |
Created | 25 Feb 2025, 22:25:39 UTC |
Sent | 25 Feb 2025, 23:03:44 UTC |
Report deadline | 5 Mar 2025, 23:03:44 UTC |
Received | 25 Feb 2025, 23:31:10 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10802589 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 32.98 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.07 MB |
Peak swap size | 2.05 MB |
Peak disk usage | 241.93 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 19:26:52 (27804): Detected: vboxwrapper 26206 2025-02-25 19:26:52 (27804): Detected: BOINC client v8.0.2 2025-02-25 19:26:53 (27804): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-25 19:26:53 (27804): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 19:26:54 (27804): Create VM. (boinc_301ad2712d6a8888, slot#1) 2025-02-25 19:26:54 (27804): Setting Memory Size for VM. (4600MB) 2025-02-25 19:26:54 (27804): Setting CPU Count for VM. (6) 2025-02-25 19:26:55 (27804): Setting Chipset Options for VM. 2025-02-25 19:26:55 (27804): Setting Graphics Controller Options for VM. 2025-02-25 19:26:55 (27804): Setting Boot Options for VM. 2025-02-25 19:26:56 (27804): Setting Network Configuration for NAT. 2025-02-25 19:26:56 (27804): Enabling VM Network Access. 2025-02-25 19:26:56 (27804): Disabling USB Support for VM. 2025-02-25 19:26:56 (27804): Disabling COM Port Support for VM. 2025-02-25 19:26:57 (27804): Disabling LPT Port Support for VM. 2025-02-25 19:26:57 (27804): Disabling Audio Support for VM. 2025-02-25 19:26:57 (27804): Disabling Clipboard Support for VM. 2025-02-25 19:26:57 (27804): Disabling Drag and Drop Support for VM. 2025-02-25 19:26:58 (27804): Adding storage controller(s) to VM. 2025-02-25 19:26:58 (27804): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-25 19:27:01 (27804): Adding VirtualBox Guest Additions to VM. 2025-02-25 19:27:01 (27804): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 19:27:01 (27804): forwarding host port 54237 to guest port 80 2025-02-25 19:27:02 (27804): Enabling remote desktop for VM. 2025-02-25 19:27:02 (27804): Required extension pack not installed, remote desktop not enabled. 2025-02-25 19:27:02 (27804): Enabling shared directory for VM. 2025-02-25 19:27:02 (27804): Starting VM using VBoxManage interface. (boinc_301ad2712d6a8888, slot#1) 2025-02-25 19:27:03 (27804): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_301ad2712d6a8888" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_301ad2712d6a8888' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_301ad2712d6a8888" to power on... 2025-02-25 19:27:03 (27804): VM failed to start. 2025-02-25 19:27:03 (27804): Could not start 2025-02-25 19:27:03 (27804): ERROR: VM failed to start 2025-02-25 19:27:03 (27804): Powering off VM. 2025-02-25 19:27:03 (27804): Deregistering VM. (boinc_301ad2712d6a8888, slot#1) 2025-02-25 19:27:03 (27804): Removing network bandwidth throttle group from VM. 2025-02-25 19:27:03 (27804): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.672721 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.672848 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.676465 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:07.676717 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:07.683210 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:07.941204 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:07.947795 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:08.208260 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.208641 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:08.224100 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:08.224198 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.225404 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:08.231857 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:08.232139 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:08.238583 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:08.462236 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.463072 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.463186 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.466593 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:08.466741 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.469445 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:08.469679 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:08.476235 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:08.729831 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:08.736866 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:08.998829 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:09.005920 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:09.533857 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:09.540885 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:09.800839 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.804150 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.804202 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.808531 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.071339 Launched VM: 173801920 pid: 29792 (0x7460) frontend: headless name: boinc_301ad2712d6a8888 00:00:10.416832 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_301ad2712d6a8888' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.417139 Watcher Reaper: Pid 29792 (0x7460) exited normally: 1 (0x1) 00:00:10.449829 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.477359 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" with version "1.19-windows" 00:00:10.493000 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox" 00:00:10.745893 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.758220 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:10.758271 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.760890 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:10.761372 DeleteVM Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.764439 DeleteVM Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:15.783128 main VirtualBox: object deletion starts 00:00:15.783738 main HostDnsMonitor: shutting down ... 00:00:15.783756 main HostDnsMonitor: shut down 00:00:15.784647 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.784818 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-25 19:26:54 (27804): Command: VBoxManage -q createvm --name "boinc_301ad2712d6a8888" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_301ad2712d6a8888' is created and registered. UUID: c2c37fb7-aea2-45ee-9e14-1de89f6e9d31 Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\boinc_301ad2712d6a8888.vbox' 2025-02-25 19:26:54 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --description "BdnLDmVWI76nsSi4ap6QjLDmwznN0nGgGQJmkKkKDm3HxKDmx0i5pn_0" Exit Code: 0 Output: 2025-02-25 19:26:54 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --memory 4600 Exit Code: 0 Output: 2025-02-25 19:26:55 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --cpus 6 Exit Code: 0 Output: 2025-02-25 19:26:55 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 19:26:55 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 19:26:56 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 19:26:56 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 19:26:56 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 19:26:56 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --usb off Exit Code: 0 Output: 2025-02-25 19:26:57 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 19:26:57 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 19:26:57 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-25 19:26:57 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --clipboard disabled Exit Code: 0 Output: 2025-02-25 19:26:58 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 19:26:58 (27804): Command: VBoxManage -q storagectl "boinc_301ad2712d6a8888" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 19:26:58 (27804): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 19:26:58 (27804): Command: VBoxManage -q storageattach "boinc_301ad2712d6a8888" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 19:26:59 (27804): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 19:27:00 (27804): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 19:27:00 (27804): Command: VBoxManage -q storageattach "boinc_301ad2712d6a8888" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 19:27:01 (27804): Command: VBoxManage -q storageattach "boinc_301ad2712d6a8888" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 19:27:01 (27804): Command: VBoxManage -q storageattach "boinc_301ad2712d6a8888" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 19:27:01 (27804): Command: VBoxManage -q storageattach "boinc_301ad2712d6a8888" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 19:27:01 (27804): Command: VBoxManage -q bandwidthctl "boinc_301ad2712d6a8888" add "boinc_301ad2712d6a8888_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 19:27:02 (27804): Command: VBoxManage -q modifyvm "boinc_301ad2712d6a8888" --natpf1 ",tcp,127.0.0.1,54237,,80" Exit Code: 0 Output: 2025-02-25 19:27:02 (27804): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 19:27:02 (27804): Command: VBoxManage -q sharedfolder add "boinc_301ad2712d6a8888" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-02-25 19:27:03 (27804): Command: VBoxManage -q startvm "boinc_301ad2712d6a8888" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_301ad2712d6a8888' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_301ad2712d6a8888\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_301ad2712d6a8888" to power on... 2025-02-25 19:27:03 (27804): Command: VBoxManage -q snapshot "boinc_301ad2712d6a8888" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 19:27:03 (27804): Command: VBoxManage -q bandwidthctl "boinc_301ad2712d6a8888" remove "boinc_301ad2712d6a8888_net" Exit Code: 0 Output: 2025-02-25 19:27:03 (27804): Command: VBoxManage -q unregistervm "boinc_301ad2712d6a8888" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 19:27:08 (27804): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN