Name | SSiLDmTWI76nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmLGxKDmntx8Io_0 |
Workunit | 230561831 |
Created | 25 Feb 2025, 22:25:09 UTC |
Sent | 25 Feb 2025, 22:56:53 UTC |
Report deadline | 5 Mar 2025, 22:56:53 UTC |
Received | 25 Feb 2025, 23:31:10 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10802589 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 32.98 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.00 MB |
Peak swap size | 2.05 MB |
Peak disk usage | 240.53 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 19:24:57 (30016): Detected: vboxwrapper 26206 2025-02-25 19:24:57 (30016): Detected: BOINC client v8.0.2 2025-02-25 19:24:58 (30016): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-25 19:24:58 (30016): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 19:24:58 (30016): Create VM. (boinc_836cc202e0a78e6f, slot#1) 2025-02-25 19:24:59 (30016): Setting Memory Size for VM. (4600MB) 2025-02-25 19:24:59 (30016): Setting CPU Count for VM. (6) 2025-02-25 19:24:59 (30016): Setting Chipset Options for VM. 2025-02-25 19:25:00 (30016): Setting Graphics Controller Options for VM. 2025-02-25 19:25:00 (30016): Setting Boot Options for VM. 2025-02-25 19:25:00 (30016): Setting Network Configuration for NAT. 2025-02-25 19:25:01 (30016): Enabling VM Network Access. 2025-02-25 19:25:01 (30016): Disabling USB Support for VM. 2025-02-25 19:25:01 (30016): Disabling COM Port Support for VM. 2025-02-25 19:25:01 (30016): Disabling LPT Port Support for VM. 2025-02-25 19:25:02 (30016): Disabling Audio Support for VM. 2025-02-25 19:25:02 (30016): Disabling Clipboard Support for VM. 2025-02-25 19:25:02 (30016): Disabling Drag and Drop Support for VM. 2025-02-25 19:25:02 (30016): Adding storage controller(s) to VM. 2025-02-25 19:25:03 (30016): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-25 19:25:06 (30016): Adding VirtualBox Guest Additions to VM. 2025-02-25 19:25:06 (30016): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 19:25:06 (30016): forwarding host port 54230 to guest port 80 2025-02-25 19:25:06 (30016): Enabling remote desktop for VM. 2025-02-25 19:25:07 (30016): Required extension pack not installed, remote desktop not enabled. 2025-02-25 19:25:07 (30016): Enabling shared directory for VM. 2025-02-25 19:25:07 (30016): Starting VM using VBoxManage interface. (boinc_836cc202e0a78e6f, slot#1) 2025-02-25 19:25:08 (30016): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_836cc202e0a78e6f" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_836cc202e0a78e6f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_836cc202e0a78e6f" to power on... 2025-02-25 19:25:08 (30016): VM failed to start. 2025-02-25 19:25:08 (30016): Could not start 2025-02-25 19:25:08 (30016): ERROR: VM failed to start 2025-02-25 19:25:08 (30016): Powering off VM. 2025-02-25 19:25:08 (30016): Deregistering VM. (boinc_836cc202e0a78e6f, slot#1) 2025-02-25 19:25:08 (30016): Removing network bandwidth throttle group from VM. 2025-02-25 19:25:08 (30016): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.421786 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.421908 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.434242 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:07.434493 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:07.441054 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:07.689060 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:07.704760 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:07.955901 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.956256 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:07.972399 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:07.972493 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.973650 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:07.980351 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:07.980639 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:07.987233 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:08.224809 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.225661 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.225762 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.238035 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:08.238182 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.240929 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:08.241230 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:08.247826 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:08.493455 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:08.509741 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:08.761711 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:08.777861 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:09.297538 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:09.313799 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:09.563725 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.567014 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.567062 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.571304 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.834824 Launched VM: 3319978816 pid: 29588 (0x7394) frontend: headless name: boinc_836cc202e0a78e6f 00:00:10.164782 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_836cc202e0a78e6f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.165096 Watcher Reaper: Pid 29588 (0x7394) exited normally: 1 (0x1) 00:00:10.198153 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.226970 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" with version "1.19-windows" 00:00:10.243108 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox" 00:00:10.479315 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.491221 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:10.491272 Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.493959 Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:10.494492 DeleteVM Saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.497645 DeleteVM Finished saving settings file "C:\Users\geore\.VirtualBox\VirtualBox.xml" 00:00:15.519902 main VirtualBox: object deletion starts 00:00:15.520557 main HostDnsMonitor: shutting down ... 00:00:15.520578 main HostDnsMonitor: shut down 00:00:15.521321 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.521488 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-25 19:24:59 (30016): Command: VBoxManage -q createvm --name "boinc_836cc202e0a78e6f" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_836cc202e0a78e6f' is created and registered. UUID: 3cf4a0d2-ad74-4ed3-950c-173d43886e79 Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\boinc_836cc202e0a78e6f.vbox' 2025-02-25 19:24:59 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --description "SSiLDmTWI76nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmLGxKDmntx8Io_0" Exit Code: 0 Output: 2025-02-25 19:24:59 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --memory 4600 Exit Code: 0 Output: 2025-02-25 19:24:59 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --cpus 6 Exit Code: 0 Output: 2025-02-25 19:25:00 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 19:25:00 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 19:25:00 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 19:25:01 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 19:25:01 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 19:25:01 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --usb off Exit Code: 0 Output: 2025-02-25 19:25:01 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 19:25:02 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 19:25:02 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-25 19:25:02 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --clipboard disabled Exit Code: 0 Output: 2025-02-25 19:25:02 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 19:25:03 (30016): Command: VBoxManage -q storagectl "boinc_836cc202e0a78e6f" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 19:25:03 (30016): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 19:25:03 (30016): Command: VBoxManage -q storageattach "boinc_836cc202e0a78e6f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 19:25:03 (30016): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 19:25:05 (30016): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 19:25:05 (30016): Command: VBoxManage -q storageattach "boinc_836cc202e0a78e6f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 19:25:05 (30016): Command: VBoxManage -q storageattach "boinc_836cc202e0a78e6f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 19:25:06 (30016): Command: VBoxManage -q storageattach "boinc_836cc202e0a78e6f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 19:25:06 (30016): Command: VBoxManage -q storageattach "boinc_836cc202e0a78e6f" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 19:25:06 (30016): Command: VBoxManage -q bandwidthctl "boinc_836cc202e0a78e6f" add "boinc_836cc202e0a78e6f_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 19:25:06 (30016): Command: VBoxManage -q modifyvm "boinc_836cc202e0a78e6f" --natpf1 ",tcp,127.0.0.1,54230,,80" Exit Code: 0 Output: 2025-02-25 19:25:07 (30016): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 19:25:07 (30016): Command: VBoxManage -q sharedfolder add "boinc_836cc202e0a78e6f" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-02-25 19:25:08 (30016): Command: VBoxManage -q startvm "boinc_836cc202e0a78e6f" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_836cc202e0a78e6f' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_836cc202e0a78e6f\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_836cc202e0a78e6f" to power on... 2025-02-25 19:25:08 (30016): Command: VBoxManage -q snapshot "boinc_836cc202e0a78e6f" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 19:25:08 (30016): Command: VBoxManage -q bandwidthctl "boinc_836cc202e0a78e6f" remove "boinc_836cc202e0a78e6f_net" Exit Code: 0 Output: 2025-02-25 19:25:08 (30016): Command: VBoxManage -q unregistervm "boinc_836cc202e0a78e6f" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 19:25:13 (30016): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN