Name | amgLDmgeF76n9Rq4apOajLDm4fhM0noT9bVoFjIUDm5AgKDm7Ph1Pn_0 |
Workunit | 230558847 |
Created | 25 Feb 2025, 19:20:38 UTC |
Sent | 25 Feb 2025, 19:23:45 UTC |
Report deadline | 5 Mar 2025, 19:23:45 UTC |
Received | 25 Feb 2025, 20:26:18 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10870311 |
Run time | |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 49.34 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 11.44 MB |
Peak swap size | 2.43 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 14:24:59 (21496): Detected: vboxwrapper 26206 2025-02-25 14:24:59 (21496): Detected: BOINC client v8.0.4 2025-02-25 14:25:00 (21496): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-25 14:25:01 (21496): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 14:25:01 (21496): Create VM. (boinc_36d5112d0b87d685, slot#7) 2025-02-25 14:25:02 (21496): Setting Memory Size for VM. (4800MB) 2025-02-25 14:25:02 (21496): Setting CPU Count for VM. (8) 2025-02-25 14:25:02 (21496): Setting Chipset Options for VM. 2025-02-25 14:25:02 (21496): Setting Graphics Controller Options for VM. 2025-02-25 14:25:03 (21496): Setting Boot Options for VM. 2025-02-25 14:25:03 (21496): Setting Network Configuration for NAT. 2025-02-25 14:25:03 (21496): Enabling VM Network Access. 2025-02-25 14:25:04 (21496): Disabling USB Support for VM. 2025-02-25 14:25:04 (21496): Disabling COM Port Support for VM. 2025-02-25 14:25:04 (21496): Disabling LPT Port Support for VM. 2025-02-25 14:25:04 (21496): Disabling Audio Support for VM. 2025-02-25 14:25:05 (21496): Disabling Clipboard Support for VM. 2025-02-25 14:25:05 (21496): Disabling Drag and Drop Support for VM. 2025-02-25 14:25:05 (21496): Adding storage controller(s) to VM. 2025-02-25 14:25:05 (21496): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-25 14:25:08 (21496): Adding VirtualBox Guest Additions to VM. 2025-02-25 14:25:08 (21496): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 14:25:09 (21496): forwarding host port 50605 to guest port 80 2025-02-25 14:25:09 (21496): Enabling remote desktop for VM. 2025-02-25 14:25:09 (21496): Required extension pack not installed, remote desktop not enabled. 2025-02-25 14:25:09 (21496): Enabling shared directory for VM. 2025-02-25 14:25:10 (21496): Starting VM using VBoxManage interface. (boinc_36d5112d0b87d685, slot#7) 2025-02-25 14:25:10 (21496): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_36d5112d0b87d685" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_36d5112d0b87d685' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_36d5112d0b87d685" to power on... 2025-02-25 14:25:10 (21496): VM failed to start. 2025-02-25 14:25:10 (21496): Could not start 2025-02-25 14:25:10 (21496): ERROR: VM failed to start 2025-02-25 14:25:10 (21496): Powering off VM. 2025-02-25 14:25:10 (21496): Deregistering VM. (boinc_36d5112d0b87d685, slot#7) 2025-02-25 14:25:10 (21496): Removing network bandwidth throttle group from VM. 2025-02-25 14:25:11 (21496): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.808495 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.808608 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.810499 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:07.810818 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:07.812052 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:08.071691 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:08.073128 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:08.325249 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.326194 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:08.328207 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:08.328349 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.329373 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:08.330356 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:08.330676 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:08.331680 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:08.594055 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.595746 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.595928 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.597601 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:08.597804 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.598770 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:08.598994 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:08.601063 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:08.867810 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:08.870065 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:09.139699 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:09.141716 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:09.662496 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:09.664262 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:09.917521 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.926669 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.926799 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.937840 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.192990 Launched VM: 2419557552 pid: 14592 (0x3900) frontend: headless name: boinc_36d5112d0b87d685 00:00:10.565332 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_36d5112d0b87d685' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.565810 Watcher Reaper: Pid 14592 (0x3900) exited normally: 1 (0x1) 00:00:10.625272 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.677638 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" with version "1.19-windows" 00:00:10.679162 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox" 00:00:10.938303 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.939995 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:10.940054 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.941085 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:10.941913 DeleteVM Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.944388 DeleteVM Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:15.956763 main VirtualBox: object deletion starts 00:00:15.957320 main HostDnsMonitor: shutting down ... 00:00:15.957357 main HostDnsMonitor: shut down 00:00:15.958832 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.959103 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\7/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-25 14:25:01 (21496): Command: VBoxManage -q createvm --name "boinc_36d5112d0b87d685" --basefolder "C:\ProgramData\BOINC\slots\7" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_36d5112d0b87d685' is created and registered. UUID: dbeb962f-c092-4384-82e0-d5acf232b619 Settings file: 'C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\boinc_36d5112d0b87d685.vbox' 2025-02-25 14:25:02 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --description "amgLDmgeF76n9Rq4apOajLDm4fhM0noT9bVoFjIUDm5AgKDm7Ph1Pn_0" Exit Code: 0 Output: 2025-02-25 14:25:02 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --memory 4800 Exit Code: 0 Output: 2025-02-25 14:25:02 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --cpus 8 Exit Code: 0 Output: 2025-02-25 14:25:02 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 14:25:03 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 14:25:03 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 14:25:03 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 14:25:04 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 14:25:04 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --usb off Exit Code: 0 Output: 2025-02-25 14:25:04 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 14:25:04 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 14:25:05 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-25 14:25:05 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --clipboard disabled Exit Code: 0 Output: 2025-02-25 14:25:05 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 14:25:05 (21496): Command: VBoxManage -q storagectl "boinc_36d5112d0b87d685" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 14:25:06 (21496): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 14:25:06 (21496): Command: VBoxManage -q storageattach "boinc_36d5112d0b87d685" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 14:25:06 (21496): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 14:25:07 (21496): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 14:25:08 (21496): Command: VBoxManage -q storageattach "boinc_36d5112d0b87d685" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 14:25:08 (21496): Command: VBoxManage -q storageattach "boinc_36d5112d0b87d685" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 14:25:08 (21496): Command: VBoxManage -q storageattach "boinc_36d5112d0b87d685" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 14:25:08 (21496): Command: VBoxManage -q storageattach "boinc_36d5112d0b87d685" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 14:25:09 (21496): Command: VBoxManage -q bandwidthctl "boinc_36d5112d0b87d685" add "boinc_36d5112d0b87d685_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 14:25:09 (21496): Command: VBoxManage -q modifyvm "boinc_36d5112d0b87d685" --natpf1 ",tcp,127.0.0.1,50605,,80" Exit Code: 0 Output: 2025-02-25 14:25:09 (21496): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 14:25:10 (21496): Command: VBoxManage -q sharedfolder add "boinc_36d5112d0b87d685" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\7/shared" Exit Code: 0 Output: 2025-02-25 14:25:10 (21496): Command: VBoxManage -q startvm "boinc_36d5112d0b87d685" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_36d5112d0b87d685' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\7\boinc_36d5112d0b87d685\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_36d5112d0b87d685" to power on... 2025-02-25 14:25:10 (21496): Command: VBoxManage -q snapshot "boinc_36d5112d0b87d685" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 14:25:11 (21496): Command: VBoxManage -q bandwidthctl "boinc_36d5112d0b87d685" remove "boinc_36d5112d0b87d685_net" Exit Code: 0 Output: 2025-02-25 14:25:11 (21496): Command: VBoxManage -q unregistervm "boinc_36d5112d0b87d685" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 14:25:16 (21496): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN