Name | EXFLDme3C76n9Rq4apOajLDm4fhM0noT9bVoFjIUDmn2fKDm5KKEQn_0 |
Workunit | 230557053 |
Created | 25 Feb 2025, 16:34:11 UTC |
Sent | 25 Feb 2025, 17:17:00 UTC |
Report deadline | 5 Mar 2025, 17:17:00 UTC |
Received | 25 Feb 2025, 18:20:44 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10870311 |
Run time | 5 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 49.34 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.11 MB |
Peak swap size | 2.20 MB |
Peak disk usage | 327.94 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 12:19:50 (14056): Detected: vboxwrapper 26206 2025-02-25 12:19:50 (14056): Detected: BOINC client v8.0.4 2025-02-25 12:19:51 (14056): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-25 12:19:51 (14056): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 12:19:52 (14056): Create VM. (boinc_354d0e9142c41477, slot#12) 2025-02-25 12:19:53 (14056): Setting Memory Size for VM. (4800MB) 2025-02-25 12:19:53 (14056): Setting CPU Count for VM. (8) 2025-02-25 12:19:53 (14056): Setting Chipset Options for VM. 2025-02-25 12:19:53 (14056): Setting Graphics Controller Options for VM. 2025-02-25 12:19:54 (14056): Setting Boot Options for VM. 2025-02-25 12:19:54 (14056): Setting Network Configuration for NAT. 2025-02-25 12:19:54 (14056): Enabling VM Network Access. 2025-02-25 12:19:54 (14056): Disabling USB Support for VM. 2025-02-25 12:19:55 (14056): Disabling COM Port Support for VM. 2025-02-25 12:19:55 (14056): Disabling LPT Port Support for VM. 2025-02-25 12:19:55 (14056): Disabling Audio Support for VM. 2025-02-25 12:19:55 (14056): Disabling Clipboard Support for VM. 2025-02-25 12:19:56 (14056): Disabling Drag and Drop Support for VM. 2025-02-25 12:19:56 (14056): Adding storage controller(s) to VM. 2025-02-25 12:19:56 (14056): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-25 12:19:59 (14056): Adding VirtualBox Guest Additions to VM. 2025-02-25 12:19:59 (14056): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 12:20:00 (14056): forwarding host port 51658 to guest port 80 2025-02-25 12:20:00 (14056): Enabling remote desktop for VM. 2025-02-25 12:20:00 (14056): Required extension pack not installed, remote desktop not enabled. 2025-02-25 12:20:00 (14056): Enabling shared directory for VM. 2025-02-25 12:20:01 (14056): Starting VM using VBoxManage interface. (boinc_354d0e9142c41477, slot#12) 2025-02-25 12:20:01 (14056): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_354d0e9142c41477" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_354d0e9142c41477' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_354d0e9142c41477" to power on... 2025-02-25 12:20:01 (14056): VM failed to start. 2025-02-25 12:20:01 (14056): Could not start 2025-02-25 12:20:01 (14056): ERROR: VM failed to start 2025-02-25 12:20:01 (14056): Powering off VM. 2025-02-25 12:20:01 (14056): Deregistering VM. (boinc_354d0e9142c41477, slot#12) 2025-02-25 12:20:01 (14056): Removing network bandwidth throttle group from VM. 2025-02-25 12:20:01 (14056): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.636097 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.636196 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.637265 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:07.637463 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:07.638355 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:07.901921 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:07.903103 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:08.164179 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.164457 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:08.165515 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:08.165594 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.166481 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:08.167381 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:08.167587 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:08.168489 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:08.431354 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.431970 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.432055 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.433271 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:08.433401 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.434475 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:08.434646 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:08.435567 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:08.697724 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:08.698953 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:08.963998 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:08.965320 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:09.480770 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:09.481947 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:09.744417 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.747217 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.747259 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.750430 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.021631 Launched VM: 1721600256 pid: 13992 (0x36a8) frontend: headless name: boinc_354d0e9142c41477 00:00:10.375997 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_354d0e9142c41477' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.376267 Watcher Reaper: Pid 13992 (0x36a8) exited normally: 1 (0x1) 00:00:10.410081 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.439199 Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" with version "1.19-windows" 00:00:10.440460 Finished saving settings file "C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox" 00:00:10.704268 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.705413 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:10.705456 Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.706273 Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:10.706691 DeleteVM Saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.707719 DeleteVM Finished saving settings file "C:\Users\Robert\.VirtualBox\VirtualBox.xml" 00:00:15.721752 main VirtualBox: object deletion starts 00:00:15.722224 main HostDnsMonitor: shutting down ... 00:00:15.722313 main HostDnsMonitor: shut down 00:00:15.723618 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.723842 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: C\slots\12/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\12\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-25 12:19:52 (14056): Command: VBoxManage -q createvm --name "boinc_354d0e9142c41477" --basefolder "C:\ProgramData\BOINC\slots\12" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_354d0e9142c41477' is created and registered. UUID: 01c7437f-7d31-4052-ad0b-eadbb8f8a221 Settings file: 'C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\boinc_354d0e9142c41477.vbox' 2025-02-25 12:19:53 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --description "EXFLDme3C76n9Rq4apOajLDm4fhM0noT9bVoFjIUDmn2fKDm5KKEQn_0" Exit Code: 0 Output: 2025-02-25 12:19:53 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --memory 4800 Exit Code: 0 Output: 2025-02-25 12:19:53 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --cpus 8 Exit Code: 0 Output: 2025-02-25 12:19:53 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 12:19:54 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 12:19:54 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 12:19:54 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 12:19:54 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 12:19:55 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --usb off Exit Code: 0 Output: 2025-02-25 12:19:55 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 12:19:55 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 12:19:55 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-25 12:19:56 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --clipboard disabled Exit Code: 0 Output: 2025-02-25 12:19:56 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 12:19:56 (14056): Command: VBoxManage -q storagectl "boinc_354d0e9142c41477" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 12:19:57 (14056): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 12:19:57 (14056): Command: VBoxManage -q storageattach "boinc_354d0e9142c41477" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 12:19:57 (14056): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 12:19:58 (14056): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 12:19:59 (14056): Command: VBoxManage -q storageattach "boinc_354d0e9142c41477" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 12:19:59 (14056): Command: VBoxManage -q storageattach "boinc_354d0e9142c41477" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 12:19:59 (14056): Command: VBoxManage -q storageattach "boinc_354d0e9142c41477" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 12:19:59 (14056): Command: VBoxManage -q storageattach "boinc_354d0e9142c41477" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 12:20:00 (14056): Command: VBoxManage -q bandwidthctl "boinc_354d0e9142c41477" add "boinc_354d0e9142c41477_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 12:20:00 (14056): Command: VBoxManage -q modifyvm "boinc_354d0e9142c41477" --natpf1 ",tcp,127.0.0.1,51658,,80" Exit Code: 0 Output: 2025-02-25 12:20:00 (14056): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 12:20:00 (14056): Command: VBoxManage -q sharedfolder add "boinc_354d0e9142c41477" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\12/shared" Exit Code: 0 Output: 2025-02-25 12:20:01 (14056): Command: VBoxManage -q startvm "boinc_354d0e9142c41477" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_354d0e9142c41477' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\12\boinc_354d0e9142c41477\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_354d0e9142c41477" to power on... 2025-02-25 12:20:01 (14056): Command: VBoxManage -q snapshot "boinc_354d0e9142c41477" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 12:20:01 (14056): Command: VBoxManage -q bandwidthctl "boinc_354d0e9142c41477" remove "boinc_354d0e9142c41477_net" Exit Code: 0 Output: 2025-02-25 12:20:02 (14056): Command: VBoxManage -q unregistervm "boinc_354d0e9142c41477" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 12:20:07 (14056): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN