Name bkhMDmVDB76n9Rq4apOajLDm4fhM0noT9bVoFjIUDmetfKDmS0eb8m_1
Workunit 230555528
Created 25 Feb 2025, 15:42:19 UTC
Sent 25 Feb 2025, 16:57:52 UTC
Report deadline 5 Mar 2025, 16:57:52 UTC
Received 25 Feb 2025, 19:07:43 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10863068
Run time 18 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 36.67 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 7.95 MB
Peak swap size 2.03 MB
Peak disk usage 241.07 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-25 20:00:49 (2552): Detected: vboxwrapper 26206
2025-02-25 20:00:49 (2552): Detected: BOINC client v8.0.2
2025-02-25 20:00:50 (2552): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-25 20:00:50 (2552): Successfully copied 'init_data.xml' to the shared directory.
2025-02-25 20:00:51 (2552): Create VM. (boinc_a7088e44b5281dbf, slot#1)
2025-02-25 20:00:51 (2552): Setting Memory Size for VM. (4600MB)
2025-02-25 20:00:52 (2552): Setting CPU Count for VM. (6)
2025-02-25 20:00:52 (2552): Setting Chipset Options for VM.
2025-02-25 20:00:52 (2552): Setting Graphics Controller Options for VM.
2025-02-25 20:00:52 (2552): Setting Boot Options for VM.
2025-02-25 20:00:53 (2552): Setting Network Configuration for NAT.
2025-02-25 20:00:53 (2552): Enabling VM Network Access.
2025-02-25 20:00:53 (2552): Disabling USB Support for VM.
2025-02-25 20:00:53 (2552): Disabling COM Port Support for VM.
2025-02-25 20:00:54 (2552): Disabling LPT Port Support for VM.
2025-02-25 20:00:54 (2552): Disabling Audio Support for VM.
2025-02-25 20:00:54 (2552): Disabling Clipboard Support for VM.
2025-02-25 20:00:55 (2552): Disabling Drag and Drop Support for VM.
2025-02-25 20:00:55 (2552): Adding storage controller(s) to VM.
2025-02-25 20:00:55 (2552): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-25 20:00:58 (2552): Adding VirtualBox Guest Additions to VM.
2025-02-25 20:00:58 (2552): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-25 20:00:58 (2552): forwarding host port 51668 to guest port 80
2025-02-25 20:00:59 (2552): Enabling remote desktop for VM.
2025-02-25 20:00:59 (2552): Required extension pack not installed, remote desktop not enabled.
2025-02-25 20:00:59 (2552): Enabling shared directory for VM.
2025-02-25 20:00:59 (2552): Starting VM using VBoxManage interface. (boinc_a7088e44b5281dbf, slot#1)
2025-02-25 20:01:00 (2552): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_a7088e44b5281dbf" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_a7088e44b5281dbf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_a7088e44b5281dbf" to power on...

2025-02-25 20:01:00 (2552): VM failed to start.
2025-02-25 20:01:00 (2552): Could not start 
2025-02-25 20:01:00 (2552): ERROR: VM failed to start
2025-02-25 20:01:00 (2552): Powering off VM.
2025-02-25 20:01:00 (2552): Deregistering VM. (boinc_a7088e44b5281dbf, slot#1)
2025-02-25 20:01:00 (2552): Removing network bandwidth throttle group from VM.
2025-02-25 20:01:00 (2552): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.569744          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.569853          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.574134          Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml"
00:00:07.574327          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:07.576750          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:07.823323          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:07.827697          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:08.075940          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.076236          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:08.078660          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:08.078741          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.079895          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:08.082428          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:08.082683          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:08.084834          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:08.331872          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.332571          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.332670          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.337005          Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml"
00:00:08.337144          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.339770          Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml"
00:00:08.339955          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:08.341960          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:08.599422          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:08.603788          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:08.855260          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:08.859877          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:09.362955          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:09.365248          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:09.617645          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:09.620341          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.620378          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.623332          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.872055          Launched VM: 2355289280 pid: 11372 (0x2c6c) frontend: headless name: boinc_a7088e44b5281dbf
00:00:10.189573 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_a7088e44b5281dbf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.189844 Watcher  Reaper: Pid 11372 (0x2c6c) exited normally: 1 (0x1)
00:00:10.219202          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.243476          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox" with version "1.19-windows"
00:00:10.245865          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox"
00:00:10.503544          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.508059          Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml"
00:00:10.508106          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.510952          Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml"
00:00:10.511393 DeleteVM Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.513858 DeleteVM Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml"
00:00:15.518770 main     VirtualBox: object deletion starts
00:00:15.519347 main     HostDnsMonitor: shutting down ...
00:00:15.519367 main     HostDnsMonitor: shut down
00:00:15.520134 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:15.520244 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

age -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-25 20:00:51 (2552): 
Command: VBoxManage -q createvm --name "boinc_a7088e44b5281dbf" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_a7088e44b5281dbf' is created and registered.
UUID: 645180e3-e994-4f9f-8bd1-4365f7cd49c6
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\boinc_a7088e44b5281dbf.vbox'

2025-02-25 20:00:51 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --description "bkhMDmVDB76n9Rq4apOajLDm4fhM0noT9bVoFjIUDmetfKDmS0eb8m_1" 
Exit Code: 0
Output:

2025-02-25 20:00:52 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --memory 4600 
Exit Code: 0
Output:

2025-02-25 20:00:52 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --cpus 6 
Exit Code: 0
Output:

2025-02-25 20:00:52 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-25 20:00:52 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-25 20:00:53 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-25 20:00:53 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-25 20:00:53 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-25 20:00:53 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --usb off 
Exit Code: 0
Output:

2025-02-25 20:00:54 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-25 20:00:54 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-25 20:00:54 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-25 20:00:55 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --clipboard disabled 
Exit Code: 0
Output:

2025-02-25 20:00:55 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-25 20:00:55 (2552): 
Command: VBoxManage -q storagectl "boinc_a7088e44b5281dbf" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-25 20:00:55 (2552): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-25 20:00:56 (2552): 
Command: VBoxManage -q storageattach "boinc_a7088e44b5281dbf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-25 20:00:56 (2552): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-25 20:00:57 (2552): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-25 20:00:57 (2552): 
Command: VBoxManage -q storageattach "boinc_a7088e44b5281dbf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-25 20:00:58 (2552): 
Command: VBoxManage -q storageattach "boinc_a7088e44b5281dbf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-25 20:00:58 (2552): 
Command: VBoxManage -q storageattach "boinc_a7088e44b5281dbf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-25 20:00:58 (2552): 
Command: VBoxManage -q storageattach "boinc_a7088e44b5281dbf" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-25 20:00:58 (2552): 
Command: VBoxManage -q bandwidthctl "boinc_a7088e44b5281dbf" add "boinc_a7088e44b5281dbf_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-25 20:00:59 (2552): 
Command: VBoxManage -q modifyvm "boinc_a7088e44b5281dbf" --natpf1 ",tcp,127.0.0.1,51668,,80" 
Exit Code: 0
Output:

2025-02-25 20:00:59 (2552): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-25 20:00:59 (2552): 
Command: VBoxManage -q sharedfolder add "boinc_a7088e44b5281dbf" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2025-02-25 20:01:00 (2552): 
Command: VBoxManage -q startvm "boinc_a7088e44b5281dbf" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_a7088e44b5281dbf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_a7088e44b5281dbf\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_a7088e44b5281dbf" to power on...

2025-02-25 20:01:00 (2552): 
Command: VBoxManage -q snapshot "boinc_a7088e44b5281dbf" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-25 20:01:00 (2552): 
Command: VBoxManage -q bandwidthctl "boinc_a7088e44b5281dbf" remove "boinc_a7088e44b5281dbf_net" 
Exit Code: 0
Output:

2025-02-25 20:01:00 (2552): 
Command: VBoxManage -q unregistervm "boinc_a7088e44b5281dbf" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

20:01:05 (2552): called boinc_finish(1)