Name | CMS_443787_1740484243.138075_0 |
Workunit | 230551385 |
Created | 25 Feb 2025, 11:50:47 UTC |
Sent | 25 Feb 2025, 12:24:09 UTC |
Report deadline | 28 Mar 2025, 12:24:09 UTC |
Received | 25 Feb 2025, 12:59:26 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10869112 |
Run time | 1 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 22.23 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 11.09 MB |
Peak swap size | 2.08 MB |
Peak disk usage | 0.75 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unzul�ssige Funktion. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 13:55:00 (11952): vboxwrapper version 26208 2025-02-25 13:55:00 (11952): BOINC client version: 8.0.2 2025-02-25 13:55:01 (11952): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-25 13:55:01 (11952): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-02-25 13:55:01 (11952): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 13:55:02 (11952): Create VM. (boinc_4cd6dec066c505f8, slot#5) 2025-02-25 13:55:02 (11952): Setting Memory Size for VM. (4584MB) 2025-02-25 13:55:02 (11952): Setting CPU Count for VM. (4) 2025-02-25 13:55:03 (11952): Setting Chipset Options for VM. 2025-02-25 13:55:03 (11952): Setting Graphics Controller Options for VM. 2025-02-25 13:55:03 (11952): Setting Boot Options for VM. 2025-02-25 13:55:03 (11952): Setting Network Configuration for NAT. 2025-02-25 13:55:04 (11952): Enabling VM Network Access. 2025-02-25 13:55:04 (11952): Disabling USB Support for VM. 2025-02-25 13:55:04 (11952): Disabling COM Port Support for VM. 2025-02-25 13:55:05 (11952): Disabling LPT Port Support for VM. 2025-02-25 13:55:05 (11952): Disabling Audio Support for VM. 2025-02-25 13:55:05 (11952): Disabling Clipboard Support for VM. 2025-02-25 13:55:05 (11952): Disabling Drag and Drop Support for VM. 2025-02-25 13:55:06 (11952): Adding storage controller(s) to VM. 2025-02-25 13:55:06 (11952): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-02-25 13:55:08 (11952): Adding VirtualBox Guest Additions to VM. 2025-02-25 13:55:08 (11952): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 13:55:08 (11952): forwarding host port 59414 to guest port 80 2025-02-25 13:55:09 (11952): Enabling remote desktop for VM. 2025-02-25 13:55:09 (11952): Required extension pack not installed, remote desktop not enabled. 2025-02-25 13:55:09 (11952): Enabling shared directory for VM. 2025-02-25 13:55:10 (11952): Starting VM using VBoxManage interface. (boinc_4cd6dec066c505f8, slot#5) 2025-02-25 13:55:10 (11952): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_4cd6dec066c505f8" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_4cd6dec066c505f8' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'E:\BOINC\slots\5\boinc_4cd6dec066c505f8\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_4cd6dec066c505f8" to power on... 2025-02-25 13:55:10 (11952): VM failed to start. 2025-02-25 13:55:10 (11952): Could not start 2025-02-25 13:55:10 (11952): ERROR: VM failed to start 2025-02-25 13:55:10 (11952): Powering off VM. 2025-02-25 13:55:10 (11952): Deregistering VM. (boinc_4cd6dec066c505f8, slot#5) 2025-02-25 13:55:10 (11952): Removing network bandwidth throttle group from VM. 2025-02-25 13:55:10 (11952): Removing VM from VirtualBox. Hypervisor System Log: 00:00:06.960198 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.960303 Saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.974216 Finished saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" 00:00:06.974472 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:06.991923 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:07.220698 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:07.239846 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:07.491660 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.491998 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:07.535141 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:07.535811 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.537132 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:07.550854 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:07.551451 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:07.599414 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:07.759463 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.760250 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.760339 Saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.771491 Finished saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" 00:00:07.771672 Saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.774795 Finished saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" 00:00:07.775092 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:07.803357 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:08.021386 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:08.045768 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:08.285569 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:08.330079 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:08.818069 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:08.986744 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:09.085936 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.089736 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.089805 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.094068 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.361510 Launched VM: 647317488 pid: 18816 (0x4980) frontend: headless name: boinc_4cd6dec066c505f8 00:00:09.738692 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_4cd6dec066c505f8' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'E:\BOINC\slots\5\boinc_4cd6dec066c505f8\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:09.739051 Watcher Reaper: Pid 18816 (0x4980) exited normally: 1 (0x1) 00:00:09.774335 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.802378 Saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" with version "1.19-windows" 00:00:09.860667 Finished saving settings file "E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox" 00:00:10.068565 Saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.081524 Finished saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" 00:00:10.081621 Saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.085133 Finished saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" 00:00:10.086043 DeleteVM Saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.089290 DeleteVM Finished saving settings file "C:\Users\MKlot\.VirtualBox\VirtualBox.xml" 00:00:15.101796 main VirtualBox: object deletion starts 00:00:15.101830 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'E:\Virtual Machines\DOS622\DOS 6.22\DOS 6.22.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:15.102496 main HostDnsMonitor: shutting down ... 00:00:15.102653 main HostDnsMonitor: shut down 00:00:15.106467 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.106700 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp 2025-02-25 13:55:02 (11952): Command: VBoxManage -q createvm --name "boinc_4cd6dec066c505f8" --basefolder "E:\BOINC\slots\5" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_4cd6dec066c505f8' is created and registered. UUID: f8c64ff4-7271-4d14-999a-aef43de992f0 Settings file: 'E:\BOINC\slots\5\boinc_4cd6dec066c505f8\boinc_4cd6dec066c505f8.vbox' 2025-02-25 13:55:02 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --description "CMS_443787_1740484243.138075_0" Exit Code: 0 Output: 2025-02-25 13:55:02 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --memory 4584 Exit Code: 0 Output: 2025-02-25 13:55:03 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --cpus 4 Exit Code: 0 Output: 2025-02-25 13:55:03 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 13:55:03 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 13:55:03 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 13:55:04 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 13:55:04 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 13:55:04 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --usb off Exit Code: 0 Output: 2025-02-25 13:55:05 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 13:55:05 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 13:55:05 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --audio-enabled off Exit Code: 0 Output: 2025-02-25 13:55:05 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --clipboard disabled Exit Code: 0 Output: 2025-02-25 13:55:06 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 13:55:06 (11952): Command: VBoxManage -q storagectl "boinc_4cd6dec066c505f8" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 13:55:06 (11952): Command: VBoxManage -q showhdinfo "E:\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: E:\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 13:55:06 (11952): Command: VBoxManage -q storageattach "boinc_4cd6dec066c505f8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'E:\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 13:55:07 (11952): Command: VBoxManage -q showhdinfo "E:\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: E:\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 13:55:07 (11952): Command: VBoxManage -q closemedium disk "E:\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 13:55:07 (11952): Command: VBoxManage -q showhdinfo "E:\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: E:\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 13:55:07 (11952): Command: VBoxManage -q storageattach "boinc_4cd6dec066c505f8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "E:\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 13:55:08 (11952): Command: VBoxManage -q storageattach "boinc_4cd6dec066c505f8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 13:55:08 (11952): Command: VBoxManage -q storageattach "boinc_4cd6dec066c505f8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 13:55:08 (11952): Command: VBoxManage -q storageattach "boinc_4cd6dec066c505f8" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 13:55:08 (11952): Command: VBoxManage -q bandwidthctl "boinc_4cd6dec066c505f8" add "boinc_4cd6dec066c505f8_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 13:55:09 (11952): Command: VBoxManage -q modifyvm "boinc_4cd6dec066c505f8" --natpf1 ",tcp,127.0.0.1,59414,,80" Exit Code: 0 Output: 2025-02-25 13:55:09 (11952): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 13:55:09 (11952): Command: VBoxManage -q sharedfolder add "boinc_4cd6dec066c505f8" --name "shared" --hostpath "E:\BOINC\slots\5/shared" Exit Code: 0 Output: 2025-02-25 13:55:10 (11952): Command: VBoxManage -q startvm "boinc_4cd6dec066c505f8" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_4cd6dec066c505f8' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'E:\BOINC\slots\5\boinc_4cd6dec066c505f8\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_4cd6dec066c505f8" to power on... 2025-02-25 13:55:10 (11952): Command: VBoxManage -q snapshot "boinc_4cd6dec066c505f8" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 13:55:10 (11952): Command: VBoxManage -q bandwidthctl "boinc_4cd6dec066c505f8" remove "boinc_4cd6dec066c505f8_net" Exit Code: 0 Output: 2025-02-25 13:55:11 (11952): Command: VBoxManage -q unregistervm "boinc_4cd6dec066c505f8" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-02-25 13:55:16 (11952): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN