Name | CMS_363228_1740453808.422880_0 |
Workunit | 230544652 |
Created | 25 Feb 2025, 3:23:30 UTC |
Sent | 25 Feb 2025, 3:42:50 UTC |
Report deadline | 28 Mar 2025, 3:42:50 UTC |
Received | 25 Feb 2025, 3:50:11 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10870180 |
Run time | 22 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 18.59 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 11.38 MB |
Peak swap size | 6.43 MB |
Peak disk usage | 0.74 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Error no especificado (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-02-25 04:42:54 (11204): vboxwrapper version 26208 2025-02-25 04:42:54 (11204): BOINC client version: 8.0.2 2025-02-25 04:42:55 (11204): Detected: VirtualBox VboxManage Interface (Version: 7.1.6) 2025-02-25 04:42:55 (11204): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-02-25 04:42:55 (11204): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 04:42:55 (11204): Create VM. (boinc_6390972d52d95334, slot#0) 2025-02-25 04:42:56 (11204): Setting Memory Size for VM. (4584MB) 2025-02-25 04:42:56 (11204): Setting CPU Count for VM. (4) 2025-02-25 04:42:57 (11204): Setting Chipset Options for VM. 2025-02-25 04:42:57 (11204): Setting Graphics Controller Options for VM. 2025-02-25 04:42:57 (11204): Setting Boot Options for VM. 2025-02-25 04:42:57 (11204): Setting Network Configuration for NAT. 2025-02-25 04:42:58 (11204): Enabling VM Network Access. 2025-02-25 04:42:58 (11204): Disabling USB Support for VM. 2025-02-25 04:42:58 (11204): Disabling COM Port Support for VM. 2025-02-25 04:42:59 (11204): Disabling LPT Port Support for VM. 2025-02-25 04:42:59 (11204): Disabling Audio Support for VM. 2025-02-25 04:42:59 (11204): Disabling Clipboard Support for VM. 2025-02-25 04:42:59 (11204): Disabling Drag and Drop Support for VM. 2025-02-25 04:43:00 (11204): Adding storage controller(s) to VM. 2025-02-25 04:43:00 (11204): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-02-25 04:43:02 (11204): Adding VirtualBox Guest Additions to VM. 2025-02-25 04:43:03 (11204): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 04:43:03 (11204): forwarding host port 64640 to guest port 80 2025-02-25 04:43:03 (11204): Enabling remote desktop for VM. 2025-02-25 04:43:03 (11204): Required extension pack not installed, remote desktop not enabled. 2025-02-25 04:43:03 (11204): Enabling shared directory for VM. 2025-02-25 04:43:04 (11204): Starting VM using VBoxManage interface. (boinc_6390972d52d95334, slot#0) 2025-02-25 04:43:09 (11204): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_6390972d52d95334" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_6390972d52d95334" to power on... 2025-02-25 04:43:09 (11204): VM failed to start. 2025-02-25 04:43:09 (11204): Could not start 2025-02-25 04:43:09 (11204): ERROR: VM failed to start 2025-02-25 04:43:09 (11204): Powering off VM. 2025-02-25 04:43:09 (11204): Deregistering VM. (boinc_6390972d52d95334, slot#0) 2025-02-25 04:43:09 (11204): Removing network bandwidth throttle group from VM. 2025-02-25 04:43:09 (11204): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.398569 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:07.400682 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:07.687867 Platform architecture set to 'x86' 00:00:07.690563 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:07.698841 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:08.012498 Platform architecture set to 'x86' 00:00:08.016542 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.017761 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:08.025002 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:08.025333 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.028902 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:08.032743 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:08.033677 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:08.037588 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:08.263469 Platform architecture set to 'x86' 00:00:08.265829 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.267674 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.267806 Saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.273083 Finished saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" 00:00:08.273290 Saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.275473 Finished saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" 00:00:08.275832 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:08.278050 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:08.562089 Platform architecture set to 'x86' 00:00:08.564096 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:08.570126 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:08.869059 Platform architecture set to 'x86' 00:00:08.872667 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:08.878467 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:09.466689 Platform architecture set to 'x86' 00:00:09.468600 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:09.474536 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:09.768974 Platform architecture set to 'x86' 00:00:09.774002 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.785266 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.785344 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.794201 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={bea3ef5c-de2f-4b74-aa3a-15d6249371a0} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0 00:00:09.795526 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.054034 Launched VM: 2224245504 pid: 11164 (0x2b9c) frontend: headless name: boinc_6390972d52d95334 00:00:13.902489 Platform architecture set to 'x86' 00:00:14.714546 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:14.725290 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:14.849315 Platform architecture set to 'x86' 00:00:14.850498 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.917589 Platform architecture set to 'x86' 00:00:14.919439 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" with version "1.19-windows" 00:00:14.925259 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox" 00:00:15.255220 Saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.260865 Finished saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" 00:00:15.260955 Saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.264117 Finished saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" 00:00:15.265446 DeleteVM Saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.268382 DeleteVM Finished saving settings file "C:\Users\Carlos\.VirtualBox\VirtualBox.xml" 00:00:20.291157 main VirtualBox: object deletion starts 00:00:20.296179 main HostDnsMonitor: shutting down ... 00:00:20.296377 main HostDnsMonitor: shut down 00:00:20.305239 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:20.305968 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: rUuid).raw(), machine.asOutParam())" at line 3219 of file VBoxManageInfo.cpp 2025-02-25 04:42:56 (11204): Command: VBoxManage -q createvm --name "boinc_6390972d52d95334" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_6390972d52d95334' is created and registered. UUID: d824db9c-b3a2-40c8-bae7-cb5e3df73ec0 Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_6390972d52d95334\boinc_6390972d52d95334.vbox' 2025-02-25 04:42:56 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --description "CMS_363228_1740453808.422880_0" Exit Code: 0 Output: 2025-02-25 04:42:56 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --memory 4584 Exit Code: 0 Output: 2025-02-25 04:42:56 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --cpus 4 Exit Code: 0 Output: 2025-02-25 04:42:57 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 04:42:57 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 04:42:57 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 04:42:58 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 04:42:58 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 04:42:58 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --usb off Exit Code: 0 Output: 2025-02-25 04:42:59 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 04:42:59 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 04:42:59 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --audio-enabled off Exit Code: 0 Output: 2025-02-25 04:42:59 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --clipboard disabled Exit Code: 0 Output: 2025-02-25 04:43:00 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 04:43:00 (11204): Command: VBoxManage -q storagectl "boinc_6390972d52d95334" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 04:43:00 (11204): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 04:43:01 (11204): Command: VBoxManage -q storageattach "boinc_6390972d52d95334" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp 2025-02-25 04:43:01 (11204): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 04:43:01 (11204): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 04:43:01 (11204): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 04:43:02 (11204): Command: VBoxManage -q storageattach "boinc_6390972d52d95334" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 04:43:02 (11204): Command: VBoxManage -q storageattach "boinc_6390972d52d95334" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 04:43:02 (11204): Command: VBoxManage -q storageattach "boinc_6390972d52d95334" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 04:43:03 (11204): Command: VBoxManage -q storageattach "boinc_6390972d52d95334" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 04:43:03 (11204): Command: VBoxManage -q bandwidthctl "boinc_6390972d52d95334" add "boinc_6390972d52d95334_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 04:43:03 (11204): Command: VBoxManage -q modifyvm "boinc_6390972d52d95334" --natpf1 ",tcp,127.0.0.1,64640,,80" Exit Code: 0 Output: 2025-02-25 04:43:03 (11204): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 04:43:04 (11204): Command: VBoxManage -q sharedfolder add "boinc_6390972d52d95334" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-25 04:43:09 (11204): Command: VBoxManage -q startvm "boinc_6390972d52d95334" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_6390972d52d95334" to power on... 2025-02-25 04:43:09 (11204): Command: VBoxManage -q snapshot "boinc_6390972d52d95334" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 04:43:09 (11204): Command: VBoxManage -q bandwidthctl "boinc_6390972d52d95334" remove "boinc_6390972d52d95334_net" Exit Code: 0 Output: 2025-02-25 04:43:10 (11204): Command: VBoxManage -q unregistervm "boinc_6390972d52d95334" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-02-25 04:43:15 (11204): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN