Name | CMS_362040_1740453205.830663_0 |
Workunit | 230544570 |
Created | 25 Feb 2025, 3:13:28 UTC |
Sent | 25 Feb 2025, 3:39:56 UTC |
Report deadline | 28 Mar 2025, 3:39:56 UTC |
Received | 25 Feb 2025, 3:51:00 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10767264 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 20.78 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 7.28 MB |
Peak swap size | 1.80 MB |
Peak disk usage | 0.74 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unzul�ssige Funktion. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 04:49:26 (21720): vboxwrapper version 26208 2025-02-25 04:49:26 (21720): BOINC client version: 8.0.2 2025-02-25 04:49:27 (21720): Detected: VirtualBox VboxManage Interface (Version: 7.0.8) 2025-02-25 04:49:27 (21720): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-02-25 04:49:27 (21720): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 04:49:28 (21720): Create VM. (boinc_3bc7bde0bb2e60ae, slot#18) 2025-02-25 04:49:28 (21720): Setting Memory Size for VM. (4584MB) 2025-02-25 04:49:28 (21720): Setting CPU Count for VM. (4) 2025-02-25 04:49:29 (21720): Setting Chipset Options for VM. 2025-02-25 04:49:29 (21720): Setting Graphics Controller Options for VM. 2025-02-25 04:49:29 (21720): Setting Boot Options for VM. 2025-02-25 04:49:30 (21720): Setting Network Configuration for NAT. 2025-02-25 04:49:30 (21720): Enabling VM Network Access. 2025-02-25 04:49:30 (21720): Disabling USB Support for VM. 2025-02-25 04:49:30 (21720): Disabling COM Port Support for VM. 2025-02-25 04:49:31 (21720): Disabling LPT Port Support for VM. 2025-02-25 04:49:31 (21720): Disabling Audio Support for VM. 2025-02-25 04:49:31 (21720): Disabling Clipboard Support for VM. 2025-02-25 04:49:32 (21720): Disabling Drag and Drop Support for VM. 2025-02-25 04:49:32 (21720): Adding storage controller(s) to VM. 2025-02-25 04:49:32 (21720): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-02-25 04:49:36 (21720): Adding VirtualBox Guest Additions to VM. 2025-02-25 04:49:36 (21720): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 04:49:36 (21720): forwarding host port 62009 to guest port 80 2025-02-25 04:49:36 (21720): Enabling remote desktop for VM. 2025-02-25 04:49:37 (21720): Required extension pack not installed, remote desktop not enabled. 2025-02-25 04:49:37 (21720): Enabling shared directory for VM. 2025-02-25 04:49:37 (21720): Starting VM using VBoxManage interface. (boinc_3bc7bde0bb2e60ae, slot#18) 2025-02-25 04:49:38 (21720): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_3bc7bde0bb2e60ae" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_3bc7bde0bb2e60ae' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_3bc7bde0bb2e60ae" to power on... 2025-02-25 04:49:38 (21720): VM failed to start. 2025-02-25 04:49:38 (21720): Could not start 2025-02-25 04:49:38 (21720): ERROR: VM failed to start 2025-02-25 04:49:38 (21720): Powering off VM. 2025-02-25 04:49:38 (21720): Deregistering VM. (boinc_3bc7bde0bb2e60ae, slot#18) 2025-02-25 04:49:38 (21720): Removing network bandwidth throttle group from VM. 2025-02-25 04:49:38 (21720): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.909113 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.909357 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.912899 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:07.913461 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:07.916338 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:08.378502 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:08.381515 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:08.676263 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.677013 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:08.680153 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:08.680399 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.682750 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:08.685537 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:08.686171 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:08.688839 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:08.975867 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.988350 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.988555 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.991924 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:08.992322 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.995547 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:08.996048 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:08.998717 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:09.255272 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:09.258433 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:09.552718 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:09.555780 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:10.136588 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:10.139631 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:10.394780 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.403142 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.403248 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.413214 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.674405 Launched VM: 2350285296 pid: 7068 (0x1b9c) frontend: headless name: boinc_3bc7bde0bb2e60ae 00:00:11.114983 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_3bc7bde0bb2e60ae' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.115499 Watcher Reaper: Pid 7068 (0x1b9c) exited normally: 1 (0x1) 00:00:11.205371 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.309491 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" with version "1.19-windows" 00:00:11.312613 Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox" 00:00:11.622130 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.625357 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:11.625475 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.628831 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:11.629876 DeleteVM Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.633271 DeleteVM Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:16.652441 main VirtualBox: object deletion starts 00:00:16.653644 main HostDnsMonitor: shutting down ... 00:00:16.653691 main HostDnsMonitor: shut down 00:00:16.656095 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.656425 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: of file VBoxManageInfo.cpp 2025-02-25 04:49:28 (21720): Command: VBoxManage -q createvm --name "boinc_3bc7bde0bb2e60ae" --basefolder "C:\ProgramData\BOINC\slots\18" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_3bc7bde0bb2e60ae' is created and registered. UUID: db33fb81-5d37-4db5-bf3c-16d1a9f75d6c Settings file: 'C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\boinc_3bc7bde0bb2e60ae.vbox' 2025-02-25 04:49:28 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --description "CMS_362040_1740453205.830663_0" Exit Code: 0 Output: 2025-02-25 04:49:28 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --memory 4584 Exit Code: 0 Output: 2025-02-25 04:49:29 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --cpus 4 Exit Code: 0 Output: 2025-02-25 04:49:29 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 04:49:29 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 04:49:30 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 04:49:30 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 04:49:30 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 04:49:30 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --usb off Exit Code: 0 Output: 2025-02-25 04:49:31 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 04:49:31 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 04:49:31 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --audio-enabled off Exit Code: 0 Output: 2025-02-25 04:49:32 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --clipboard disabled Exit Code: 0 Output: 2025-02-25 04:49:32 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 04:49:32 (21720): Command: VBoxManage -q storagectl "boinc_3bc7bde0bb2e60ae" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 04:49:32 (21720): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 04:49:33 (21720): Command: VBoxManage -q storageattach "boinc_3bc7bde0bb2e60ae" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 04:49:33 (21720): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 04:49:34 (21720): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 04:49:34 (21720): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 04:49:35 (21720): Command: VBoxManage -q storageattach "boinc_3bc7bde0bb2e60ae" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 04:49:35 (21720): Command: VBoxManage -q storageattach "boinc_3bc7bde0bb2e60ae" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 04:49:36 (21720): Command: VBoxManage -q storageattach "boinc_3bc7bde0bb2e60ae" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-25 04:49:36 (21720): Command: VBoxManage -q storageattach "boinc_3bc7bde0bb2e60ae" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 04:49:36 (21720): Command: VBoxManage -q bandwidthctl "boinc_3bc7bde0bb2e60ae" add "boinc_3bc7bde0bb2e60ae_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 04:49:36 (21720): Command: VBoxManage -q modifyvm "boinc_3bc7bde0bb2e60ae" --natpf1 ",tcp,127.0.0.1,62009,,80" Exit Code: 0 Output: 2025-02-25 04:49:37 (21720): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 04:49:37 (21720): Command: VBoxManage -q sharedfolder add "boinc_3bc7bde0bb2e60ae" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\18/shared" Exit Code: 0 Output: 2025-02-25 04:49:38 (21720): Command: VBoxManage -q startvm "boinc_3bc7bde0bb2e60ae" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_3bc7bde0bb2e60ae' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\18\boinc_3bc7bde0bb2e60ae\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_3bc7bde0bb2e60ae" to power on... 2025-02-25 04:49:38 (21720): Command: VBoxManage -q snapshot "boinc_3bc7bde0bb2e60ae" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 04:49:38 (21720): Command: VBoxManage -q bandwidthctl "boinc_3bc7bde0bb2e60ae" remove "boinc_3bc7bde0bb2e60ae_net" Exit Code: 0 Output: 2025-02-25 04:49:39 (21720): Command: VBoxManage -q unregistervm "boinc_3bc7bde0bb2e60ae" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-02-25 04:49:44 (21720): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN