Name | Theory_2814-3954299-29_2 |
Workunit | 230303683 |
Created | 24 Feb 2025, 9:44:21 UTC |
Sent | 24 Feb 2025, 14:59:16 UTC |
Report deadline | 7 Mar 2025, 14:59:16 UTC |
Received | 24 Feb 2025, 18:30:00 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10678221 |
Run time | 33 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.18 GFLOPS |
Application version | Theory Simulation v300.60 (vbox64_theory) windows_x86_64 |
Peak working set size | 11.71 MB |
Peak swap size | 6.25 MB |
Peak disk usage | 1.07 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-02-24 11:32:35 (7000): vboxwrapper version 26208 2025-02-24 11:32:35 (7000): BOINC client version: 8.0.2 2025-02-24 11:32:36 (7000): Detected: VirtualBox VboxManage Interface (Version: 7.0.22) 2025-02-24 11:32:36 (7000): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-02-24 11:32:36 (7000): Successfully copied 'init_data.xml' to the shared directory. 2025-02-24 11:32:36 (7000): Successfully copied 'input' to the shared directory. 2025-02-24 11:32:37 (7000): Create VM. (boinc_71b0a479a112cfdd, slot#0) 2025-02-24 11:32:37 (7000): Setting Memory Size for VM. (630MB) 2025-02-24 11:32:38 (7000): Setting CPU Count for VM. (1) 2025-02-24 11:32:38 (7000): Setting Chipset Options for VM. 2025-02-24 11:32:39 (7000): Setting Graphics Controller Options for VM. 2025-02-24 11:32:39 (7000): Setting Boot Options for VM. 2025-02-24 11:32:40 (7000): Setting Network Configuration for NAT. 2025-02-24 11:32:40 (7000): Enabling VM Network Access. 2025-02-24 11:32:41 (7000): Disabling USB Support for VM. 2025-02-24 11:32:41 (7000): Disabling COM Port Support for VM. 2025-02-24 11:32:41 (7000): Disabling LPT Port Support for VM. 2025-02-24 11:32:42 (7000): Disabling Audio Support for VM. 2025-02-24 11:32:42 (7000): Disabling Clipboard Support for VM. 2025-02-24 11:32:43 (7000): Disabling Drag and Drop Support for VM. 2025-02-24 11:32:43 (7000): Adding storage controller(s) to VM. 2025-02-24 11:32:44 (7000): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi) 2025-02-24 11:32:49 (7000): Adding VirtualBox Guest Additions to VM. 2025-02-24 11:32:50 (7000): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-24 11:32:50 (7000): forwarding host port 50560 to guest port 80 2025-02-24 11:32:51 (7000): Enabling remote desktop for VM. 2025-02-24 11:32:52 (7000): Enabling shared directory for VM. 2025-02-24 11:32:54 (7000): Starting VM using VBoxManage interface. (boinc_71b0a479a112cfdd, slot#0) 2025-02-24 11:32:59 (7000): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_71b0a479a112cfdd" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_71b0a479a112cfdd" to power on... 2025-02-24 11:33:00 (7000): VM failed to start. 2025-02-24 11:33:00 (7000): Could not start 2025-02-24 11:33:00 (7000): ERROR: VM failed to start 2025-02-24 11:33:00 (7000): Powering off VM. 2025-02-24 11:33:00 (7000): Deregistering VM. (boinc_71b0a479a112cfdd, slot#0) 2025-02-24 11:33:00 (7000): Removing network bandwidth throttle group from VM. 2025-02-24 11:33:00 (7000): Removing VM from VirtualBox. Hypervisor System Log: 00:00:11.538117 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.538334 Saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.563115 Finished saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" 00:00:11.563733 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:11.586578 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:12.244332 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:12.285767 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:13.143413 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.144104 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:13.162540 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:13.162813 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.165008 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:13.185435 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:13.186089 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:13.227895 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:13.842037 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.843660 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.843838 Saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.871394 Finished saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" 00:00:13.871772 Saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.897153 Finished saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" 00:00:13.897644 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:13.920849 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:14.454640 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:14.471763 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:15.272385 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:15.294773 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:16.143688 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:16.168523 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:16.738472 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:16.762511 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:17.623627 ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0 00:00:17.632553 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:17.632685 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:17.840497 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:18.427948 Launched VM: 3231218608 pid: 6576 (0x19b0) frontend: headless name: boinc_71b0a479a112cfdd 00:00:23.242045 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:23.268304 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:24.322522 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:24.572607 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" with version "1.19-windows" 00:00:24.612242 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_71b0a479a112cfdd\boinc_71b0a479a112cfdd.vbox" 00:00:25.326228 Saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:25.353729 Finished saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" 00:00:25.353851 Saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:25.370963 Finished saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" 00:00:25.372043 DeleteVM Saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:25.395665 DeleteVM Finished saving settings file "C:\Users\stubb\.VirtualBox\VirtualBox.xml" 00:00:30.415466 main VirtualBox: object deletion starts 00:00:30.417333 main HostDnsMonitor: shutting down ... 00:00:30.417369 main HostDnsMonitor: shut down 00:00:30.419290 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:30.419720 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: heory_2814-3954299-29_2" Exit Code: 0 Output: 2025-02-24 11:32:38 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --memory 630 Exit Code: 0 Output: 2025-02-24 11:32:38 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --cpus 1 Exit Code: 0 Output: 2025-02-24 11:32:39 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-24 11:32:39 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-24 11:32:40 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-24 11:32:40 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-24 11:32:41 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --cableconnected1 on Exit Code: 0 Output: 2025-02-24 11:32:41 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --usb off Exit Code: 0 Output: 2025-02-24 11:32:41 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-24 11:32:42 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-24 11:32:42 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --audio-enabled off Exit Code: 0 Output: 2025-02-24 11:32:43 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --clipboard disabled Exit Code: 0 Output: 2025-02-24 11:32:43 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --draganddrop disabled Exit Code: 0 Output: 2025-02-24 11:32:44 (7000): Command: VBoxManage -q storagectl "boinc_71b0a479a112cfdd" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-24 11:32:44 (7000): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-24 11:32:45 (7000): Command: VBoxManage -q storageattach "boinc_71b0a479a112cfdd" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-24 11:32:46 (7000): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-24 11:32:46 (7000): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-24 11:32:47 (7000): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-24 11:32:47 (7000): Command: VBoxManage -q storageattach "boinc_71b0a479a112cfdd" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-24 11:32:48 (7000): Command: VBoxManage -q storageattach "boinc_71b0a479a112cfdd" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-24 11:32:49 (7000): Command: VBoxManage -q storageattach "boinc_71b0a479a112cfdd" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-24 11:32:50 (7000): Command: VBoxManage -q storageattach "boinc_71b0a479a112cfdd" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-24 11:32:50 (7000): Command: VBoxManage -q bandwidthctl "boinc_71b0a479a112cfdd" add "boinc_71b0a479a112cfdd_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-24 11:32:51 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --natpf1 ",tcp,127.0.0.1,50560,,80" Exit Code: 0 Output: 2025-02-24 11:32:51 (7000): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 7.0.22 Revision: 165102 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: true Why unusable: 2025-02-24 11:32:52 (7000): Command: VBoxManage -q modifyvm "boinc_71b0a479a112cfdd" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 50567 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-02-24 11:32:53 (7000): Command: VBoxManage -q sharedfolder add "boinc_71b0a479a112cfdd" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-24 11:32:59 (7000): Command: VBoxManage -q startvm "boinc_71b0a479a112cfdd" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_71b0a479a112cfdd" to power on... 2025-02-24 11:33:00 (7000): Command: VBoxManage -q snapshot "boinc_71b0a479a112cfdd" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-24 11:33:00 (7000): Command: VBoxManage -q bandwidthctl "boinc_71b0a479a112cfdd" remove "boinc_71b0a479a112cfdd_net" Exit Code: 0 Output: 2025-02-24 11:33:01 (7000): Command: VBoxManage -q unregistervm "boinc_71b0a479a112cfdd" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-02-24 11:33:06 (7000): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN