Name | PKRLDmS9I66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmm2uKDmdhaHFm_2 |
Workunit | 230522257 |
Created | 23 Feb 2025, 17:06:49 UTC |
Sent | 23 Feb 2025, 22:57:51 UTC |
Report deadline | 3 Mar 2025, 22:57:51 UTC |
Received | 24 Feb 2025, 0:03:10 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10863810 |
Run time | 20 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 30.86 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.34 MB |
Peak swap size | 2.04 MB |
Peak disk usage | 327.53 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-23 18:02:11 (50004): Detected: vboxwrapper 26206 2025-02-23 18:02:11 (50004): Detected: BOINC client v8.0.2 2025-02-23 18:02:12 (50004): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-23 18:02:13 (50004): Successfully copied 'init_data.xml' to the shared directory. 2025-02-23 18:02:13 (50004): Create VM. (boinc_9f429bcacdb9a550, slot#1) 2025-02-23 18:02:14 (50004): Setting Memory Size for VM. (4800MB) 2025-02-23 18:02:14 (50004): Setting CPU Count for VM. (8) 2025-02-23 18:02:14 (50004): Setting Chipset Options for VM. 2025-02-23 18:02:15 (50004): Setting Graphics Controller Options for VM. 2025-02-23 18:02:15 (50004): Setting Boot Options for VM. 2025-02-23 18:02:15 (50004): Setting Network Configuration for NAT. 2025-02-23 18:02:16 (50004): Enabling VM Network Access. 2025-02-23 18:02:16 (50004): Disabling USB Support for VM. 2025-02-23 18:02:16 (50004): Disabling COM Port Support for VM. 2025-02-23 18:02:17 (50004): Disabling LPT Port Support for VM. 2025-02-23 18:02:17 (50004): Disabling Audio Support for VM. 2025-02-23 18:02:17 (50004): Disabling Clipboard Support for VM. 2025-02-23 18:02:17 (50004): Disabling Drag and Drop Support for VM. 2025-02-23 18:02:18 (50004): Adding storage controller(s) to VM. 2025-02-23 18:02:18 (50004): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-23 18:02:21 (50004): Adding VirtualBox Guest Additions to VM. 2025-02-23 18:02:21 (50004): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-23 18:02:22 (50004): forwarding host port 57711 to guest port 80 2025-02-23 18:02:22 (50004): Enabling remote desktop for VM. 2025-02-23 18:02:22 (50004): Required extension pack not installed, remote desktop not enabled. 2025-02-23 18:02:22 (50004): Enabling shared directory for VM. 2025-02-23 18:02:23 (50004): Starting VM using VBoxManage interface. (boinc_9f429bcacdb9a550, slot#1) 2025-02-23 18:02:24 (50004): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_9f429bcacdb9a550" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_9f429bcacdb9a550' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_9f429bcacdb9a550" to power on... 2025-02-23 18:02:24 (50004): VM failed to start. 2025-02-23 18:02:24 (50004): Could not start 2025-02-23 18:02:24 (50004): ERROR: VM failed to start 2025-02-23 18:02:24 (50004): Powering off VM. 2025-02-23 18:02:24 (50004): Deregistering VM. (boinc_9f429bcacdb9a550, slot#1) 2025-02-23 18:02:24 (50004): Removing network bandwidth throttle group from VM. 2025-02-23 18:02:24 (50004): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.535016 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.535364 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.542427 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:08.543189 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:08.549055 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:08.823725 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:08.831758 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:09.102788 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.103958 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:09.110311 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:09.110671 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.117380 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:09.123539 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:09.124410 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:09.130229 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:09.398489 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.401676 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.401961 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.410667 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:09.411198 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.417673 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:09.418331 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:09.424243 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:09.674515 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:09.682692 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:09.951234 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:09.955958 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:10.470491 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:10.476546 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:10.744924 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.751955 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.752047 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.760519 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.149605 Launched VM: 906289888 pid: 50752 (0xc640) frontend: headless name: boinc_9f429bcacdb9a550 00:00:11.722932 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_9f429bcacdb9a550' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.723623 Watcher Reaper: Pid 50752 (0xc640) exited normally: 1 (0x1) 00:00:11.951870 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.153582 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" with version "1.19-windows" 00:00:12.161909 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox" 00:00:12.447259 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.456513 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:12.456702 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.463483 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:12.465003 DeleteVM Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.471831 DeleteVM Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:17.492499 main VirtualBox: object deletion starts 00:00:17.494345 main HostDnsMonitor: shutting down ... 00:00:17.494409 main HostDnsMonitor: shut down 00:00:17.496633 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:17.497066 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-23 18:02:14 (50004): Command: VBoxManage -q createvm --name "boinc_9f429bcacdb9a550" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_9f429bcacdb9a550' is created and registered. UUID: 92c0d111-35b5-4128-9087-4a10bb46865b Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\boinc_9f429bcacdb9a550.vbox' 2025-02-23 18:02:14 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --description "PKRLDmS9I66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmm2uKDmdhaHFm_2" Exit Code: 0 Output: 2025-02-23 18:02:14 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --memory 4800 Exit Code: 0 Output: 2025-02-23 18:02:14 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --cpus 8 Exit Code: 0 Output: 2025-02-23 18:02:15 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-23 18:02:15 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-23 18:02:15 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-23 18:02:16 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-23 18:02:16 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --cableconnected1 on Exit Code: 0 Output: 2025-02-23 18:02:16 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --usb off Exit Code: 0 Output: 2025-02-23 18:02:17 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-23 18:02:17 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-23 18:02:17 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-23 18:02:17 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --clipboard disabled Exit Code: 0 Output: 2025-02-23 18:02:18 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --draganddrop disabled Exit Code: 0 Output: 2025-02-23 18:02:18 (50004): Command: VBoxManage -q storagectl "boinc_9f429bcacdb9a550" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-23 18:02:18 (50004): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 18:02:19 (50004): Command: VBoxManage -q storageattach "boinc_9f429bcacdb9a550" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-23 18:02:19 (50004): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 18:02:20 (50004): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 18:02:20 (50004): Command: VBoxManage -q storageattach "boinc_9f429bcacdb9a550" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 18:02:21 (50004): Command: VBoxManage -q storageattach "boinc_9f429bcacdb9a550" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-23 18:02:21 (50004): Command: VBoxManage -q storageattach "boinc_9f429bcacdb9a550" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 18:02:21 (50004): Command: VBoxManage -q storageattach "boinc_9f429bcacdb9a550" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-23 18:02:22 (50004): Command: VBoxManage -q bandwidthctl "boinc_9f429bcacdb9a550" add "boinc_9f429bcacdb9a550_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-23 18:02:22 (50004): Command: VBoxManage -q modifyvm "boinc_9f429bcacdb9a550" --natpf1 ",tcp,127.0.0.1,57711,,80" Exit Code: 0 Output: 2025-02-23 18:02:22 (50004): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-23 18:02:22 (50004): Command: VBoxManage -q sharedfolder add "boinc_9f429bcacdb9a550" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-02-23 18:02:24 (50004): Command: VBoxManage -q startvm "boinc_9f429bcacdb9a550" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_9f429bcacdb9a550' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_9f429bcacdb9a550\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_9f429bcacdb9a550" to power on... 2025-02-23 18:02:24 (50004): Command: VBoxManage -q snapshot "boinc_9f429bcacdb9a550" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-23 18:02:24 (50004): Command: VBoxManage -q bandwidthctl "boinc_9f429bcacdb9a550" remove "boinc_9f429bcacdb9a550_net" Exit Code: 0 Output: 2025-02-23 18:02:24 (50004): Command: VBoxManage -q unregistervm "boinc_9f429bcacdb9a550" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 18:02:30 (50004): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN