Name | lYvLDmSOS66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmQdvKDm6EcG1m_0 |
Workunit | 230528067 |
Created | 23 Feb 2025, 14:44:38 UTC |
Sent | 23 Feb 2025, 20:47:32 UTC |
Report deadline | 3 Mar 2025, 20:47:32 UTC |
Received | 23 Feb 2025, 20:49:55 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10869666 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 6.00 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.96 MB |
Peak swap size | 2.04 MB |
Peak disk usage | 331.04 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-23 15:47:52 (13244): Detected: vboxwrapper 26206 2025-02-23 15:47:52 (13244): Detected: BOINC client v8.0.4 2025-02-23 15:47:53 (13244): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-23 15:47:54 (13244): Successfully copied 'init_data.xml' to the shared directory. 2025-02-23 15:47:54 (13244): Create VM. (boinc_463369a3794daf23, slot#0) 2025-02-23 15:47:55 (13244): Setting Memory Size for VM. (4600MB) 2025-02-23 15:47:55 (13244): Setting CPU Count for VM. (6) 2025-02-23 15:47:55 (13244): Setting Chipset Options for VM. 2025-02-23 15:47:55 (13244): Setting Graphics Controller Options for VM. 2025-02-23 15:47:56 (13244): Setting Boot Options for VM. 2025-02-23 15:47:56 (13244): Setting Network Configuration for NAT. 2025-02-23 15:47:56 (13244): Enabling VM Network Access. 2025-02-23 15:47:56 (13244): Disabling USB Support for VM. 2025-02-23 15:47:57 (13244): Disabling COM Port Support for VM. 2025-02-23 15:47:57 (13244): Disabling LPT Port Support for VM. 2025-02-23 15:47:57 (13244): Disabling Audio Support for VM. 2025-02-23 15:47:57 (13244): Disabling Clipboard Support for VM. 2025-02-23 15:47:58 (13244): Disabling Drag and Drop Support for VM. 2025-02-23 15:47:58 (13244): Adding storage controller(s) to VM. 2025-02-23 15:47:58 (13244): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-23 15:48:01 (13244): Adding VirtualBox Guest Additions to VM. 2025-02-23 15:48:01 (13244): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-23 15:48:02 (13244): forwarding host port 59892 to guest port 80 2025-02-23 15:48:02 (13244): Enabling remote desktop for VM. 2025-02-23 15:48:02 (13244): Required extension pack not installed, remote desktop not enabled. 2025-02-23 15:48:02 (13244): Enabling shared directory for VM. 2025-02-23 15:48:03 (13244): Starting VM using VBoxManage interface. (boinc_463369a3794daf23, slot#0) 2025-02-23 15:48:03 (13244): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_463369a3794daf23" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_463369a3794daf23' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_463369a3794daf23" to power on... 2025-02-23 15:48:03 (13244): VM failed to start. 2025-02-23 15:48:03 (13244): Could not start 2025-02-23 15:48:03 (13244): ERROR: VM failed to start 2025-02-23 15:48:03 (13244): Powering off VM. 2025-02-23 15:48:03 (13244): Deregistering VM. (boinc_463369a3794daf23, slot#0) 2025-02-23 15:48:03 (13244): Removing network bandwidth throttle group from VM. 2025-02-23 15:48:03 (13244): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.563375 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.563460 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.564965 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:07.565240 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:07.566284 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:07.828880 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:07.831520 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:08.088101 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.088458 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:08.091305 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:08.091534 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.092893 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:08.094197 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:08.094586 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:08.095892 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:08.352847 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.353446 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.353526 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.357212 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:08.357543 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.359053 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:08.359410 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:08.360636 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:08.619513 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:08.622519 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:08.886581 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:08.887643 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:09.412212 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:09.414357 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:09.678686 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.680825 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.680863 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.683130 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.938490 Launched VM: 3101027984 pid: 6412 (0x190c) frontend: headless name: boinc_463369a3794daf23 00:00:10.282830 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_463369a3794daf23' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.283186 Watcher Reaper: Pid 6412 (0x190c) exited normally: 1 (0x1) 00:00:10.315894 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.344153 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" with version "1.19-windows" 00:00:10.346954 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox" 00:00:10.607790 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.610401 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:10.610443 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.611581 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:10.612211 DeleteVM Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.613670 DeleteVM Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:15.616685 main VirtualBox: object deletion starts 00:00:15.617211 main HostDnsMonitor: shutting down ... 00:00:15.617235 main HostDnsMonitor: shut down 00:00:15.618331 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.618471 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-23 15:47:54 (13244): Command: VBoxManage -q createvm --name "boinc_463369a3794daf23" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_463369a3794daf23' is created and registered. UUID: 8358f6b0-3057-4629-937b-0774debc8937 Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\boinc_463369a3794daf23.vbox' 2025-02-23 15:47:55 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --description "lYvLDmSOS66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmQdvKDm6EcG1m_0" Exit Code: 0 Output: 2025-02-23 15:47:55 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --memory 4600 Exit Code: 0 Output: 2025-02-23 15:47:55 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --cpus 6 Exit Code: 0 Output: 2025-02-23 15:47:55 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-23 15:47:56 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-23 15:47:56 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-23 15:47:56 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-23 15:47:56 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --cableconnected1 on Exit Code: 0 Output: 2025-02-23 15:47:57 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --usb off Exit Code: 0 Output: 2025-02-23 15:47:57 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-23 15:47:57 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-23 15:47:57 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-23 15:47:58 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --clipboard disabled Exit Code: 0 Output: 2025-02-23 15:47:58 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --draganddrop disabled Exit Code: 0 Output: 2025-02-23 15:47:58 (13244): Command: VBoxManage -q storagectl "boinc_463369a3794daf23" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-23 15:47:59 (13244): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 15:47:59 (13244): Command: VBoxManage -q storageattach "boinc_463369a3794daf23" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-23 15:47:59 (13244): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 15:48:00 (13244): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 15:48:01 (13244): Command: VBoxManage -q storageattach "boinc_463369a3794daf23" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 15:48:01 (13244): Command: VBoxManage -q storageattach "boinc_463369a3794daf23" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-23 15:48:01 (13244): Command: VBoxManage -q storageattach "boinc_463369a3794daf23" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 15:48:01 (13244): Command: VBoxManage -q storageattach "boinc_463369a3794daf23" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-23 15:48:02 (13244): Command: VBoxManage -q bandwidthctl "boinc_463369a3794daf23" add "boinc_463369a3794daf23_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-23 15:48:02 (13244): Command: VBoxManage -q modifyvm "boinc_463369a3794daf23" --natpf1 ",tcp,127.0.0.1,59892,,80" Exit Code: 0 Output: 2025-02-23 15:48:02 (13244): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-23 15:48:02 (13244): Command: VBoxManage -q sharedfolder add "boinc_463369a3794daf23" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-23 15:48:03 (13244): Command: VBoxManage -q startvm "boinc_463369a3794daf23" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_463369a3794daf23' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_463369a3794daf23\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_463369a3794daf23" to power on... 2025-02-23 15:48:03 (13244): Command: VBoxManage -q snapshot "boinc_463369a3794daf23" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-23 15:48:03 (13244): Command: VBoxManage -q bandwidthctl "boinc_463369a3794daf23" remove "boinc_463369a3794daf23_net" Exit Code: 0 Output: 2025-02-23 15:48:04 (13244): Command: VBoxManage -q unregistervm "boinc_463369a3794daf23" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 15:48:09 (13244): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN