Name | UeDMDm5pO66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmAPvKDmlSK3Sm_0 |
Workunit | 230525562 |
Created | 23 Feb 2025, 10:56:40 UTC |
Sent | 23 Feb 2025, 16:20:42 UTC |
Report deadline | 3 Mar 2025, 16:20:42 UTC |
Received | 23 Feb 2025, 17:21:30 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10848068 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 44.98 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.94 MB |
Peak swap size | 2.06 MB |
Peak disk usage | 328.45 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-23 10:21:09 (21464): Detected: vboxwrapper 26206 2025-02-23 10:21:09 (21464): Detected: BOINC client v7.24.1 2025-02-23 10:21:10 (21464): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-23 10:21:10 (21464): Successfully copied 'init_data.xml' to the shared directory. 2025-02-23 10:21:10 (21464): Create VM. (boinc_abf7bb9a1a61fbdb, slot#5) 2025-02-23 10:21:11 (21464): Setting Memory Size for VM. (4800MB) 2025-02-23 10:21:11 (21464): Setting CPU Count for VM. (8) 2025-02-23 10:21:11 (21464): Setting Chipset Options for VM. 2025-02-23 10:21:12 (21464): Setting Graphics Controller Options for VM. 2025-02-23 10:21:12 (21464): Setting Boot Options for VM. 2025-02-23 10:21:12 (21464): Setting Network Configuration for NAT. 2025-02-23 10:21:13 (21464): Enabling VM Network Access. 2025-02-23 10:21:13 (21464): Disabling USB Support for VM. 2025-02-23 10:21:13 (21464): Disabling COM Port Support for VM. 2025-02-23 10:21:13 (21464): Disabling LPT Port Support for VM. 2025-02-23 10:21:14 (21464): Disabling Audio Support for VM. 2025-02-23 10:21:14 (21464): Disabling Clipboard Support for VM. 2025-02-23 10:21:14 (21464): Disabling Drag and Drop Support for VM. 2025-02-23 10:21:14 (21464): Adding storage controller(s) to VM. 2025-02-23 10:21:15 (21464): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-23 10:21:18 (21464): Adding VirtualBox Guest Additions to VM. 2025-02-23 10:21:18 (21464): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-23 10:21:18 (21464): forwarding host port 59183 to guest port 80 2025-02-23 10:21:18 (21464): Enabling remote desktop for VM. 2025-02-23 10:21:19 (21464): Required extension pack not installed, remote desktop not enabled. 2025-02-23 10:21:19 (21464): Enabling shared directory for VM. 2025-02-23 10:21:19 (21464): Starting VM using VBoxManage interface. (boinc_abf7bb9a1a61fbdb, slot#5) 2025-02-23 10:21:20 (21464): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_abf7bb9a1a61fbdb" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_abf7bb9a1a61fbdb' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_abf7bb9a1a61fbdb" to power on... 2025-02-23 10:21:20 (21464): VM failed to start. 2025-02-23 10:21:20 (21464): Could not start 2025-02-23 10:21:20 (21464): ERROR: VM failed to start 2025-02-23 10:21:20 (21464): Powering off VM. 2025-02-23 10:21:20 (21464): Deregistering VM. (boinc_abf7bb9a1a61fbdb, slot#5) 2025-02-23 10:21:20 (21464): Removing network bandwidth throttle group from VM. 2025-02-23 10:21:20 (21464): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.916198 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.916370 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.920410 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:07.920758 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:07.924441 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:08.190037 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:08.194735 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:08.440476 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.441030 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:08.444789 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:08.444937 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.446593 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:08.450401 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:08.450802 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:08.454810 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:08.710243 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.711592 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.711757 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.717464 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:08.717738 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.721721 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:08.722064 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:08.725760 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:08.988080 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:08.992045 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:09.275046 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:09.279867 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:09.812428 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:09.817112 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:10.072495 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.079076 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.079165 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.085512 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.341028 Launched VM: 2731674736 pid: 3328 (0xd00) frontend: headless name: boinc_abf7bb9a1a61fbdb 00:00:11.008121 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_abf7bb9a1a61fbdb' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.008680 Watcher Reaper: Pid 3328 (0xd00) exited normally: 1 (0x1) 00:00:11.070752 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.126829 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" with version "1.19-windows" 00:00:11.131149 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox" 00:00:11.391448 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.395463 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:11.395593 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.398965 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:11.399769 DeleteVM Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.403403 DeleteVM Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:16.421026 main VirtualBox: object deletion starts 00:00:16.421975 main HostDnsMonitor: shutting down ... 00:00:16.422120 main HostDnsMonitor: shut down 00:00:16.423506 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.423693 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\5/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\5\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-23 10:21:11 (21464): Command: VBoxManage -q createvm --name "boinc_abf7bb9a1a61fbdb" --basefolder "C:\ProgramData\BOINC\slots\5" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_abf7bb9a1a61fbdb' is created and registered. UUID: 83baf198-b579-452a-9ee6-1db741cf3267 Settings file: 'C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\boinc_abf7bb9a1a61fbdb.vbox' 2025-02-23 10:21:11 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --description "UeDMDm5pO66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmAPvKDmlSK3Sm_0" Exit Code: 0 Output: 2025-02-23 10:21:11 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --memory 4800 Exit Code: 0 Output: 2025-02-23 10:21:11 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --cpus 8 Exit Code: 0 Output: 2025-02-23 10:21:12 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-23 10:21:12 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-23 10:21:12 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-23 10:21:13 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-23 10:21:13 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --cableconnected1 on Exit Code: 0 Output: 2025-02-23 10:21:13 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --usb off Exit Code: 0 Output: 2025-02-23 10:21:13 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-23 10:21:14 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-23 10:21:14 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-23 10:21:14 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --clipboard disabled Exit Code: 0 Output: 2025-02-23 10:21:14 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --draganddrop disabled Exit Code: 0 Output: 2025-02-23 10:21:15 (21464): Command: VBoxManage -q storagectl "boinc_abf7bb9a1a61fbdb" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-23 10:21:15 (21464): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 10:21:15 (21464): Command: VBoxManage -q storageattach "boinc_abf7bb9a1a61fbdb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-23 10:21:15 (21464): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 10:21:17 (21464): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 10:21:17 (21464): Command: VBoxManage -q storageattach "boinc_abf7bb9a1a61fbdb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 10:21:17 (21464): Command: VBoxManage -q storageattach "boinc_abf7bb9a1a61fbdb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-23 10:21:18 (21464): Command: VBoxManage -q storageattach "boinc_abf7bb9a1a61fbdb" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 10:21:18 (21464): Command: VBoxManage -q storageattach "boinc_abf7bb9a1a61fbdb" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-23 10:21:18 (21464): Command: VBoxManage -q bandwidthctl "boinc_abf7bb9a1a61fbdb" add "boinc_abf7bb9a1a61fbdb_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-23 10:21:18 (21464): Command: VBoxManage -q modifyvm "boinc_abf7bb9a1a61fbdb" --natpf1 ",tcp,127.0.0.1,59183,,80" Exit Code: 0 Output: 2025-02-23 10:21:19 (21464): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-23 10:21:19 (21464): Command: VBoxManage -q sharedfolder add "boinc_abf7bb9a1a61fbdb" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\5/shared" Exit Code: 0 Output: 2025-02-23 10:21:20 (21464): Command: VBoxManage -q startvm "boinc_abf7bb9a1a61fbdb" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_abf7bb9a1a61fbdb' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\5\boinc_abf7bb9a1a61fbdb\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_abf7bb9a1a61fbdb" to power on... 2025-02-23 10:21:20 (21464): Command: VBoxManage -q snapshot "boinc_abf7bb9a1a61fbdb" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-23 10:21:20 (21464): Command: VBoxManage -q bandwidthctl "boinc_abf7bb9a1a61fbdb" remove "boinc_abf7bb9a1a61fbdb_net" Exit Code: 0 Output: 2025-02-23 10:21:20 (21464): Command: VBoxManage -q unregistervm "boinc_abf7bb9a1a61fbdb" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 10:21:26 (21464): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN