Name | 5DLNDmdlM66n9Rq4apOajLDm4fhM0noT9bVoFjIUDmFpeKDmE0jUjn_0 |
Workunit | 230524351 |
Created | 23 Feb 2025, 8:44:04 UTC |
Sent | 23 Feb 2025, 14:17:06 UTC |
Report deadline | 3 Mar 2025, 14:17:06 UTC |
Received | 23 Feb 2025, 15:36:05 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10866513 |
Run time | |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 8.00 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 11.25 MB |
Peak swap size | 2.15 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-23 14:35:43 (8980): Detected: vboxwrapper 26206 2025-02-23 14:35:43 (8980): Detected: BOINC client v8.0.2 2025-02-23 14:35:44 (8980): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-23 14:35:44 (8980): Successfully copied 'init_data.xml' to the shared directory. 2025-02-23 14:35:44 (8980): Create VM. (boinc_4a42e18beb3bee55, slot#1) 2025-02-23 14:35:45 (8980): Setting Memory Size for VM. (4800MB) 2025-02-23 14:35:45 (8980): Setting CPU Count for VM. (8) 2025-02-23 14:35:46 (8980): Setting Chipset Options for VM. 2025-02-23 14:35:46 (8980): Setting Graphics Controller Options for VM. 2025-02-23 14:35:46 (8980): Setting Boot Options for VM. 2025-02-23 14:35:46 (8980): Setting Network Configuration for NAT. 2025-02-23 14:35:47 (8980): Enabling VM Network Access. 2025-02-23 14:35:47 (8980): Disabling USB Support for VM. 2025-02-23 14:35:47 (8980): Disabling COM Port Support for VM. 2025-02-23 14:35:47 (8980): Disabling LPT Port Support for VM. 2025-02-23 14:35:48 (8980): Disabling Audio Support for VM. 2025-02-23 14:35:48 (8980): Disabling Clipboard Support for VM. 2025-02-23 14:35:48 (8980): Disabling Drag and Drop Support for VM. 2025-02-23 14:35:48 (8980): Adding storage controller(s) to VM. 2025-02-23 14:35:49 (8980): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-23 14:35:52 (8980): Adding VirtualBox Guest Additions to VM. 2025-02-23 14:35:52 (8980): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-23 14:35:52 (8980): forwarding host port 62229 to guest port 80 2025-02-23 14:35:52 (8980): Enabling remote desktop for VM. 2025-02-23 14:35:53 (8980): Required extension pack not installed, remote desktop not enabled. 2025-02-23 14:35:53 (8980): Enabling shared directory for VM. 2025-02-23 14:35:53 (8980): Starting VM using VBoxManage interface. (boinc_4a42e18beb3bee55, slot#1) 2025-02-23 14:35:54 (8980): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_4a42e18beb3bee55" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_4a42e18beb3bee55' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_4a42e18beb3bee55" to power on... 2025-02-23 14:35:54 (8980): VM failed to start. 2025-02-23 14:35:54 (8980): Could not start 2025-02-23 14:35:54 (8980): ERROR: VM failed to start 2025-02-23 14:35:54 (8980): Powering off VM. 2025-02-23 14:35:54 (8980): Deregistering VM. (boinc_4a42e18beb3bee55, slot#1) 2025-02-23 14:35:54 (8980): Removing network bandwidth throttle group from VM. 2025-02-23 14:35:54 (8980): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.823098 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:08.080726 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:08.084587 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:08.348292 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.348766 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:08.352376 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:08.352521 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.354210 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:08.356631 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:08.357050 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:08.359666 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:08.608570 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.608870 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.609346 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:08.613102 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:08.877806 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:08.880404 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:09.140385 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:09.142905 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:09.669358 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:09.673143 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:09.931121 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.936046 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.936106 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.942004 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.203788 Launched VM: 2701744992 pid: 17728 (0x4540) frontend: headless name: boinc_4a42e18beb3bee55 00:00:10.590998 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_4a42e18beb3bee55' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.591344 Watcher Reaper: Pid 17728 (0x4540) exited normally: 1 (0x1) 00:00:10.635953 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.674833 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" with version "1.19-windows" 00:00:10.677308 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox" 00:00:10.936528 Saving settings file "C:\Users\john_\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.940797 Finished saving settings file "C:\Users\john_\.VirtualBox\VirtualBox.xml" 00:00:10.940905 Saving settings file "C:\Users\john_\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.943306 Finished saving settings file "C:\Users\john_\.VirtualBox\VirtualBox.xml" 00:00:10.944095 DeleteVM Saving settings file "C:\Users\john_\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.946906 DeleteVM Finished saving settings file "C:\Users\john_\.VirtualBox\VirtualBox.xml" 00:00:15.971040 main VirtualBox: object deletion starts 00:00:15.971086 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\john_\VirtualBox VMs\Windows 3.11\Win98.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:15.971397 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\john_\VirtualBox VMs\win3.11\Windows 2000_1.vhd' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:15.971673 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\john_\VirtualBox VMs\Windows 98\Windows 3.11 Clone_1.vmdk' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:15.971686 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\john_\VirtualBox VMs\Windows 98\Windows 3.11 Clone-disk1.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:15.972918 main HostDnsMonitor: shutting down ... 00:00:15.972940 main HostDnsMonitor: shut down 00:00:15.974551 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.974746 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: age -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-23 14:35:45 (8980): Command: VBoxManage -q createvm --name "boinc_4a42e18beb3bee55" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_4a42e18beb3bee55' is created and registered. UUID: 06f39bd2-9678-4f67-998c-ce0aa895ce02 Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\boinc_4a42e18beb3bee55.vbox' 2025-02-23 14:35:45 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --description "5DLNDmdlM66n9Rq4apOajLDm4fhM0noT9bVoFjIUDmFpeKDmE0jUjn_0" Exit Code: 0 Output: 2025-02-23 14:35:45 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --memory 4800 Exit Code: 0 Output: 2025-02-23 14:35:46 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --cpus 8 Exit Code: 0 Output: 2025-02-23 14:35:46 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-23 14:35:46 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-23 14:35:46 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-23 14:35:47 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-23 14:35:47 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --cableconnected1 on Exit Code: 0 Output: 2025-02-23 14:35:47 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --usb off Exit Code: 0 Output: 2025-02-23 14:35:47 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-23 14:35:48 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-23 14:35:48 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-23 14:35:48 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --clipboard disabled Exit Code: 0 Output: 2025-02-23 14:35:48 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --draganddrop disabled Exit Code: 0 Output: 2025-02-23 14:35:49 (8980): Command: VBoxManage -q storagectl "boinc_4a42e18beb3bee55" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-23 14:35:49 (8980): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 14:35:49 (8980): Command: VBoxManage -q storageattach "boinc_4a42e18beb3bee55" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-23 14:35:50 (8980): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 14:35:51 (8980): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 14:35:51 (8980): Command: VBoxManage -q storageattach "boinc_4a42e18beb3bee55" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 14:35:51 (8980): Command: VBoxManage -q storageattach "boinc_4a42e18beb3bee55" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-23 14:35:52 (8980): Command: VBoxManage -q storageattach "boinc_4a42e18beb3bee55" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 14:35:52 (8980): Command: VBoxManage -q storageattach "boinc_4a42e18beb3bee55" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-23 14:35:52 (8980): Command: VBoxManage -q bandwidthctl "boinc_4a42e18beb3bee55" add "boinc_4a42e18beb3bee55_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-23 14:35:52 (8980): Command: VBoxManage -q modifyvm "boinc_4a42e18beb3bee55" --natpf1 ",tcp,127.0.0.1,62229,,80" Exit Code: 0 Output: 2025-02-23 14:35:53 (8980): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-23 14:35:53 (8980): Command: VBoxManage -q sharedfolder add "boinc_4a42e18beb3bee55" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-02-23 14:35:54 (8980): Command: VBoxManage -q startvm "boinc_4a42e18beb3bee55" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_4a42e18beb3bee55' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_4a42e18beb3bee55\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_4a42e18beb3bee55" to power on... 2025-02-23 14:35:54 (8980): Command: VBoxManage -q snapshot "boinc_4a42e18beb3bee55" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-23 14:35:54 (8980): Command: VBoxManage -q bandwidthctl "boinc_4a42e18beb3bee55" remove "boinc_4a42e18beb3bee55_net" Exit Code: 0 Output: 2025-02-23 14:35:54 (8980): Command: VBoxManage -q unregistervm "boinc_4a42e18beb3bee55" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 14:35:59 (8980): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN