Name Theory_2814-4074525-44_1
Workunit 230504898
Created 23 Feb 2025, 7:20:43 UTC
Sent 24 Feb 2025, 6:13:48 UTC
Report deadline 7 Mar 2025, 6:13:48 UTC
Received 24 Feb 2025, 9:30:29 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10861685
Run time 15 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 5.67 GFLOPS
Application version Theory Simulation v300.60 (vbox64_theory)
windows_x86_64
Peak working set size 7.04 MB
Peak swap size 1.78 MB
Peak disk usage 1.07 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-24 00:14:19 (5860): vboxwrapper version 26208
2025-02-24 00:14:19 (5860): BOINC client version: 8.0.2
2025-02-24 00:14:20 (5860): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-24 00:14:20 (5860): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2025-02-24 00:14:20 (5860): Successfully copied 'init_data.xml' to the shared directory.
2025-02-24 00:14:20 (5860): Successfully copied 'input' to the shared directory.
2025-02-24 00:14:21 (5860): Create VM. (boinc_14191ad140b7a2a2, slot#3)
2025-02-24 00:14:21 (5860): Setting Memory Size for VM. (630MB)
2025-02-24 00:14:21 (5860): Setting CPU Count for VM. (1)
2025-02-24 00:14:22 (5860): Setting Chipset Options for VM.
2025-02-24 00:14:22 (5860): Setting Graphics Controller Options for VM.
2025-02-24 00:14:22 (5860): Setting Boot Options for VM.
2025-02-24 00:14:22 (5860): Setting Network Configuration for NAT.
2025-02-24 00:14:23 (5860): Enabling VM Network Access.
2025-02-24 00:14:23 (5860): Disabling USB Support for VM.
2025-02-24 00:14:23 (5860): Disabling COM Port Support for VM.
2025-02-24 00:14:23 (5860): Disabling LPT Port Support for VM.
2025-02-24 00:14:24 (5860): Disabling Audio Support for VM.
2025-02-24 00:14:24 (5860): Disabling Clipboard Support for VM.
2025-02-24 00:14:24 (5860): Disabling Drag and Drop Support for VM.
2025-02-24 00:14:25 (5860): Adding storage controller(s) to VM.
2025-02-24 00:14:25 (5860): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi)
2025-02-24 00:14:27 (5860): Attempts: 2
2025-02-24 00:14:27 (5860): Adding VirtualBox Guest Additions to VM.
2025-02-24 00:14:28 (5860): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-24 00:14:28 (5860): forwarding host port 52723 to guest port 80
2025-02-24 00:14:28 (5860): Enabling remote desktop for VM.
2025-02-24 00:14:29 (5860): Required extension pack not installed, remote desktop not enabled.
2025-02-24 00:14:29 (5860): Enabling shared directory for VM.
2025-02-24 00:14:29 (5860): Starting VM using VBoxManage interface. (boinc_14191ad140b7a2a2, slot#3)
2025-02-24 00:14:29 (5860): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_14191ad140b7a2a2" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_14191ad140b7a2a2' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_14191ad140b7a2a2\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_14191ad140b7a2a2" to power on...

2025-02-24 00:14:29 (5860): VM failed to start.
2025-02-24 00:14:29 (5860): Could not start 
2025-02-24 00:14:29 (5860): ERROR: VM failed to start
2025-02-24 00:14:29 (5860): Powering off VM.
2025-02-24 00:14:29 (5860): Deregistering VM. (boinc_14191ad140b7a2a2, slot#3)
2025-02-24 00:14:29 (5860): Removing network bandwidth throttle group from VM.
2025-02-24 00:14:33 (5860): Attempts: 3
2025-02-24 00:14:33 (5860): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:38.338100          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:38.548909          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:38.549157          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:38.549529          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox" with version "1.19-windows"
00:00:38.552186          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox"
00:00:38.597525          Launched VM: 478260960 pid: 6284 (0x188c) frontend: headless name: boinc_0d47090490eef3d8
00:00:38.816959          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox" with version "1.19-windows"
00:00:38.821472          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox"
00:00:38.942119 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_0d47090490eef3d8' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:38.942530 Watcher  Reaper: Pid 6284 (0x188c) exited normally: 1 (0x1)
00:00:38.980326          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:39.012076          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox" with version "1.19-windows"
00:00:39.014473          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox"
00:00:39.066938          Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:39.068300          Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml"
00:00:39.068976 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_865ab41dce3ecab8\boinc_865ab41dce3ecab8.vbox" with version "1.19-windows"
00:00:39.071683 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_865ab41dce3ecab8\boinc_865ab41dce3ecab8.vbox"
00:00:39.089066          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox" with version "1.19-windows"
00:00:39.091473          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox"
00:00:39.619676          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox" with version "1.19-windows"
00:00:39.622134          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox"
00:00:39.886011          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:39.889213          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:39.889261          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:39.893005          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:40.156114          Launched VM: 478255056 pid: 5644 (0x160c) frontend: headless name: boinc_8afb4313b874c0b9
00:00:40.403345          Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:40.408248          Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml"
00:00:40.408414          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox" with version "1.19-windows"
00:00:40.410468          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox"
00:00:40.411208 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox" with version "1.19-windows"
00:00:40.413838 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox"
00:00:40.502433 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_8afb4313b874c0b9' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:40.502805 Watcher  Reaper: Pid 5644 (0x160c) exited normally: 1 (0x1)
00:00:40.537984          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:40.569449          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox" with version "1.19-windows"
00:00:40.572469          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8afb4313b874c0b9\boinc_8afb4313b874c0b9.vbox"
00:00:40.832958          Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:40.837712          Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml"
00:00:40.838493 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox" with version "1.19-windows"
00:00:40.841219 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0d47090490eef3d8\boinc_0d47090490eef3d8.vbox"
00:00:41.364800          Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:41.367052          Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml"
00:00:41.367121          Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:41.368289          Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml"
00:00:41.368879 DeleteVM Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:41.370570 DeleteVM Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml"
00:00:46.381185 main     VirtualBox: object deletion starts
00:00:46.381896 main     HostDnsMonitor: shutting down ...
00:00:46.381914 main     HostDnsMonitor: shut down
00:00:46.382698 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:46.382876 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

               
Default audio driver:            Windows Audio Session
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       
User language:                   C

2025-02-24 00:14:20 (5860): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2025-02-24T06:14:20.521000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: yes
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: yes
Processor supports unrestricted guest: yes
Processor supports nested HW virtualization: yes
Processor supports virt. vmsave/vmload: yes
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 5 6600H with Radeon Graphics
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 5 6600H with Radeon Graphics
Memory size: 13051 MByte
Memory available: 8749 MByte
Operating system: Windows 11
Operating system version: 10.0.26100

2025-02-24 00:14:21 (5860): 
Command: VBoxManage -q showvminfo "boinc_14191ad140b7a2a2" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_14191ad140b7a2a2'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp

2025-02-24 00:14:21 (5860): 
Command: VBoxManage -q createvm --name "boinc_14191ad140b7a2a2" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_14191ad140b7a2a2' is created and registered.
UUID: 069c2d5d-e148-4f7a-a3d7-e0bbc71da5d1
Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_14191ad140b7a2a2\boinc_14191ad140b7a2a2.vbox'

2025-02-24 00:14:21 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --description "Theory_2814-4074525-44_1" 
Exit Code: 0
Output:

2025-02-24 00:14:21 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --memory 630 
Exit Code: 0
Output:

2025-02-24 00:14:22 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --cpus 1 
Exit Code: 0
Output:

2025-02-24 00:14:22 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-24 00:14:22 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-24 00:14:22 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-24 00:14:23 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-24 00:14:23 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-24 00:14:23 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --usb off 
Exit Code: 0
Output:

2025-02-24 00:14:23 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-24 00:14:24 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-24 00:14:24 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --audio-enabled off 
Exit Code: 0
Output:

2025-02-24 00:14:24 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --clipboard disabled 
Exit Code: 0
Output:

2025-02-24 00:14:25 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-24 00:14:25 (5860): 
Command: VBoxManage -q storagectl "boinc_14191ad140b7a2a2" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-24 00:14:27 (5860): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:
UUID:           6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   781 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576
Child UUIDs:    cced40db-322e-4818-bc32-9ebc195d7952
                7db49e90-1902-41f4-bbc5-684434023395

2025-02-24 00:14:27 (5860): 
Command: VBoxManage -q storageattach "boinc_14191ad140b7a2a2" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-02-24 00:14:28 (5860): 
Command: VBoxManage -q storageattach "boinc_14191ad140b7a2a2" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-24 00:14:28 (5860): 
Command: VBoxManage -q bandwidthctl "boinc_14191ad140b7a2a2" add "boinc_14191ad140b7a2a2_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-24 00:14:28 (5860): 
Command: VBoxManage -q modifyvm "boinc_14191ad140b7a2a2" --natpf1 ",tcp,127.0.0.1,52723,,80" 
Exit Code: 0
Output:

2025-02-24 00:14:29 (5860): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-24 00:14:29 (5860): 
Command: VBoxManage -q sharedfolder add "boinc_14191ad140b7a2a2" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared"
Exit Code: 0
Output:

2025-02-24 00:14:29 (5860): 
Command: VBoxManage -q startvm "boinc_14191ad140b7a2a2" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_14191ad140b7a2a2' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_14191ad140b7a2a2\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_14191ad140b7a2a2" to power on...

2025-02-24 00:14:29 (5860): 
Command: VBoxManage -q snapshot "boinc_14191ad140b7a2a2" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-24 00:14:30 (5860): 
Command: VBoxManage -q bandwidthctl "boinc_14191ad140b7a2a2" remove "boinc_14191ad140b7a2a2_net" 
Exit Code: 0
Output:

2025-02-24 00:14:33 (5860): 
Command: VBoxManage -q unregistervm "boinc_14191ad140b7a2a2" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-02-24 00:14:41 (5860): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN