Name vj9MDmYDG66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmHsuKDmEh20Dn_0
Workunit 230520438
Created 23 Feb 2025, 1:44:24 UTC
Sent 23 Feb 2025, 7:39:48 UTC
Report deadline 3 Mar 2025, 7:39:48 UTC
Received 23 Feb 2025, 8:46:47 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10848453
Run time 20 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 27.33 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 8.01 MB
Peak swap size 2.04 MB
Peak disk usage 325.28 MB

Stderr output

<core_client_version>8.0.4</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-23 02:45:27 (12736): Detected: vboxwrapper 26206
2025-02-23 02:45:27 (12736): Detected: BOINC client v8.0.4
2025-02-23 02:45:29 (12736): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-23 02:45:29 (12736): Successfully copied 'init_data.xml' to the shared directory.
2025-02-23 02:45:30 (12736): Create VM. (boinc_0bc0573963cdffaf, slot#1)
2025-02-23 02:45:30 (12736): Setting Memory Size for VM. (4800MB)
2025-02-23 02:45:31 (12736): Setting CPU Count for VM. (8)
2025-02-23 02:45:31 (12736): Setting Chipset Options for VM.
2025-02-23 02:45:31 (12736): Setting Graphics Controller Options for VM.
2025-02-23 02:45:31 (12736): Setting Boot Options for VM.
2025-02-23 02:45:32 (12736): Setting Network Configuration for NAT.
2025-02-23 02:45:32 (12736): Enabling VM Network Access.
2025-02-23 02:45:32 (12736): Disabling USB Support for VM.
2025-02-23 02:45:32 (12736): Disabling COM Port Support for VM.
2025-02-23 02:45:33 (12736): Disabling LPT Port Support for VM.
2025-02-23 02:45:33 (12736): Disabling Audio Support for VM.
2025-02-23 02:45:33 (12736): Disabling Clipboard Support for VM.
2025-02-23 02:45:34 (12736): Disabling Drag and Drop Support for VM.
2025-02-23 02:45:34 (12736): Adding storage controller(s) to VM.
2025-02-23 02:45:34 (12736): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-23 02:45:37 (12736): Adding VirtualBox Guest Additions to VM.
2025-02-23 02:45:37 (12736): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-23 02:45:38 (12736): forwarding host port 56643 to guest port 80
2025-02-23 02:45:38 (12736): Enabling remote desktop for VM.
2025-02-23 02:45:38 (12736): Required extension pack not installed, remote desktop not enabled.
2025-02-23 02:45:38 (12736): Enabling shared directory for VM.
2025-02-23 02:45:39 (12736): Starting VM using VBoxManage interface. (boinc_0bc0573963cdffaf, slot#1)
2025-02-23 02:45:39 (12736): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_0bc0573963cdffaf" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_0bc0573963cdffaf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_0bc0573963cdffaf" to power on...

2025-02-23 02:45:39 (12736): VM failed to start.
2025-02-23 02:45:39 (12736): Could not start 
2025-02-23 02:45:39 (12736): ERROR: VM failed to start
2025-02-23 02:45:39 (12736): Powering off VM.
2025-02-23 02:45:39 (12736): Deregistering VM. (boinc_0bc0573963cdffaf, slot#1)
2025-02-23 02:45:39 (12736): Removing network bandwidth throttle group from VM.
2025-02-23 02:45:40 (12736): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:08.346997          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:08.599489          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:08.605413          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:08.864565          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.865955          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:08.872034          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:08.872619          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.879777          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:08.885455          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:08.886761          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:08.899307          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:09.140624          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.165221          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.165656          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.174382          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:09.175446          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.185089          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:09.186255          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:09.192155          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:09.411872          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:09.417249          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:09.684263          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:09.689411          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:10.223001          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:10.228251          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:10.484850          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:10.502537          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.502776          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.521142          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.773407          Launched VM: 766180064 pid: 14612 (0x3914) frontend: headless name: boinc_0bc0573963cdffaf
00:00:11.299554 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_0bc0573963cdffaf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:11.300151 Watcher  Reaper: Pid 14612 (0x3914) exited normally: 1 (0x1)
00:00:11.375587          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.436909          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox" with version "1.19-windows"
00:00:11.439764          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox"
00:00:11.713144          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.716683          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:11.716781          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.720897          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:11.722253 DeleteVM Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.727912 DeleteVM Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:16.748933 main     VirtualBox: object deletion starts
00:00:16.748997 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\Hilda\VirtualBox VMs\Montana-AMD\Snapshots/{6eb7b533-a2f9-44ed-85bd-176ecdeefdbe}.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:16.749053 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\Hilda\VirtualBox VMs\Montana-AMD\Montana-AMD.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:16.750155 main     ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={6cc49055-dad4-4496-85cf-3f76bcb3b5fa} aComponent={SnapshotWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.751192 main     HostDnsMonitor: shutting down ...
00:00:16.751248 main     HostDnsMonitor: shut down
00:00:16.752740 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.752947 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

a\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-23 02:45:30 (12736): 
Command: VBoxManage -q createvm --name "boinc_0bc0573963cdffaf" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_0bc0573963cdffaf' is created and registered.
UUID: 1dcaf557-f981-4183-aa16-fea74fd2480a
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\boinc_0bc0573963cdffaf.vbox'

2025-02-23 02:45:30 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --description "vj9MDmYDG66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmHsuKDmEh20Dn_0" 
Exit Code: 0
Output:

2025-02-23 02:45:31 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --memory 4800 
Exit Code: 0
Output:

2025-02-23 02:45:31 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --cpus 8 
Exit Code: 0
Output:

2025-02-23 02:45:31 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-23 02:45:31 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-23 02:45:32 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-23 02:45:32 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-23 02:45:32 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-23 02:45:32 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --usb off 
Exit Code: 0
Output:

2025-02-23 02:45:33 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-23 02:45:33 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-23 02:45:33 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-23 02:45:34 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --clipboard disabled 
Exit Code: 0
Output:

2025-02-23 02:45:34 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-23 02:45:34 (12736): 
Command: VBoxManage -q storagectl "boinc_0bc0573963cdffaf" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-23 02:45:34 (12736): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-23 02:45:35 (12736): 
Command: VBoxManage -q storageattach "boinc_0bc0573963cdffaf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-23 02:45:35 (12736): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-23 02:45:36 (12736): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-23 02:45:36 (12736): 
Command: VBoxManage -q storageattach "boinc_0bc0573963cdffaf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-23 02:45:37 (12736): 
Command: VBoxManage -q storageattach "boinc_0bc0573963cdffaf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-23 02:45:37 (12736): 
Command: VBoxManage -q storageattach "boinc_0bc0573963cdffaf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-23 02:45:37 (12736): 
Command: VBoxManage -q storageattach "boinc_0bc0573963cdffaf" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-23 02:45:38 (12736): 
Command: VBoxManage -q bandwidthctl "boinc_0bc0573963cdffaf" add "boinc_0bc0573963cdffaf_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-23 02:45:38 (12736): 
Command: VBoxManage -q modifyvm "boinc_0bc0573963cdffaf" --natpf1 ",tcp,127.0.0.1,56643,,80" 
Exit Code: 0
Output:

2025-02-23 02:45:38 (12736): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-23 02:45:38 (12736): 
Command: VBoxManage -q sharedfolder add "boinc_0bc0573963cdffaf" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2025-02-23 02:45:39 (12736): 
Command: VBoxManage -q startvm "boinc_0bc0573963cdffaf" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_0bc0573963cdffaf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_0bc0573963cdffaf\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_0bc0573963cdffaf" to power on...

2025-02-23 02:45:39 (12736): 
Command: VBoxManage -q snapshot "boinc_0bc0573963cdffaf" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-23 02:45:40 (12736): 
Command: VBoxManage -q bandwidthctl "boinc_0bc0573963cdffaf" remove "boinc_0bc0573963cdffaf_net" 
Exit Code: 0
Output:

2025-02-23 02:45:40 (12736): 
Command: VBoxManage -q unregistervm "boinc_0bc0573963cdffaf" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

02:45:45 (12736): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN