Name | LaTLDmLpF66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmEquKDmv5WtOm_0 |
Workunit | 230520117 |
Created | 23 Feb 2025, 1:19:13 UTC |
Sent | 23 Feb 2025, 7:16:23 UTC |
Report deadline | 3 Mar 2025, 7:16:23 UTC |
Received | 23 Feb 2025, 9:15:57 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10863810 |
Run time | 21 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 30.86 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.34 MB |
Peak swap size | 2.03 MB |
Peak disk usage | 325.26 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-23 03:15:43 (44312): Detected: vboxwrapper 26206 2025-02-23 03:15:43 (44312): Detected: BOINC client v8.0.2 2025-02-23 03:15:44 (44312): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-23 03:15:45 (44312): Successfully copied 'init_data.xml' to the shared directory. 2025-02-23 03:15:46 (44312): Create VM. (boinc_8c9c2797e3f42766, slot#10) 2025-02-23 03:15:46 (44312): Setting Memory Size for VM. (4800MB) 2025-02-23 03:15:46 (44312): Setting CPU Count for VM. (8) 2025-02-23 03:15:47 (44312): Setting Chipset Options for VM. 2025-02-23 03:15:47 (44312): Setting Graphics Controller Options for VM. 2025-02-23 03:15:47 (44312): Setting Boot Options for VM. 2025-02-23 03:15:48 (44312): Setting Network Configuration for NAT. 2025-02-23 03:15:48 (44312): Enabling VM Network Access. 2025-02-23 03:15:48 (44312): Disabling USB Support for VM. 2025-02-23 03:15:48 (44312): Disabling COM Port Support for VM. 2025-02-23 03:15:49 (44312): Disabling LPT Port Support for VM. 2025-02-23 03:15:49 (44312): Disabling Audio Support for VM. 2025-02-23 03:15:49 (44312): Disabling Clipboard Support for VM. 2025-02-23 03:15:50 (44312): Disabling Drag and Drop Support for VM. 2025-02-23 03:15:50 (44312): Adding storage controller(s) to VM. 2025-02-23 03:15:50 (44312): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-23 03:15:53 (44312): Adding VirtualBox Guest Additions to VM. 2025-02-23 03:15:54 (44312): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-23 03:15:54 (44312): forwarding host port 53117 to guest port 80 2025-02-23 03:15:54 (44312): Enabling remote desktop for VM. 2025-02-23 03:15:54 (44312): Required extension pack not installed, remote desktop not enabled. 2025-02-23 03:15:54 (44312): Enabling shared directory for VM. 2025-02-23 03:15:55 (44312): Starting VM using VBoxManage interface. (boinc_8c9c2797e3f42766, slot#10) 2025-02-23 03:15:56 (44312): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_8c9c2797e3f42766" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_8c9c2797e3f42766' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_8c9c2797e3f42766" to power on... 2025-02-23 03:15:56 (44312): VM failed to start. 2025-02-23 03:15:56 (44312): Could not start 2025-02-23 03:15:56 (44312): ERROR: VM failed to start 2025-02-23 03:15:56 (44312): Powering off VM. 2025-02-23 03:15:56 (44312): Deregistering VM. (boinc_8c9c2797e3f42766, slot#10) 2025-02-23 03:15:56 (44312): Removing network bandwidth throttle group from VM. 2025-02-23 03:15:56 (44312): Removing VM from VirtualBox. Hypervisor System Log: 00:00:09.197288 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.197623 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.206947 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:09.207759 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:09.213792 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:09.486684 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:09.494690 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:09.788900 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.790036 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:09.798100 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:09.798412 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.804601 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:09.810224 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:09.811038 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:09.816674 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:10.079497 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.082724 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.083028 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.090335 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:10.090878 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.097794 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:10.098508 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:10.104413 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:10.370881 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:10.379219 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:10.652724 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:10.660988 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:11.213466 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:11.222088 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:11.502553 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:11.516074 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.516261 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.532183 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.800584 Launched VM: 1395213952 pid: 47772 (0xba9c) frontend: headless name: boinc_8c9c2797e3f42766 00:00:12.360359 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_8c9c2797e3f42766' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:12.360764 Watcher Reaper: Pid 47772 (0xba9c) exited normally: 1 (0x1) 00:00:12.476377 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.574972 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" with version "1.19-windows" 00:00:12.580853 Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox" 00:00:12.905298 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.911823 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:12.911977 Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.918193 Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:12.919594 DeleteVM Saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.925761 DeleteVM Finished saving settings file "C:\Users\hicks\.VirtualBox\VirtualBox.xml" 00:00:17.948089 main VirtualBox: object deletion starts 00:00:17.950465 main HostDnsMonitor: shutting down ... 00:00:17.950566 main HostDnsMonitor: shut down 00:00:17.953560 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:17.953936 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: C\slots\10/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-23 03:15:46 (44312): Command: VBoxManage -q createvm --name "boinc_8c9c2797e3f42766" --basefolder "C:\ProgramData\BOINC\slots\10" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_8c9c2797e3f42766' is created and registered. UUID: 1bdb20d4-e6c4-4d5a-9388-a60a048f38c0 Settings file: 'C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\boinc_8c9c2797e3f42766.vbox' 2025-02-23 03:15:46 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --description "LaTLDmLpF66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmEquKDmv5WtOm_0" Exit Code: 0 Output: 2025-02-23 03:15:46 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --memory 4800 Exit Code: 0 Output: 2025-02-23 03:15:47 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --cpus 8 Exit Code: 0 Output: 2025-02-23 03:15:47 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-23 03:15:47 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-23 03:15:48 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-23 03:15:48 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-23 03:15:48 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --cableconnected1 on Exit Code: 0 Output: 2025-02-23 03:15:48 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --usb off Exit Code: 0 Output: 2025-02-23 03:15:49 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-23 03:15:49 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-23 03:15:49 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-23 03:15:50 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --clipboard disabled Exit Code: 0 Output: 2025-02-23 03:15:50 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --draganddrop disabled Exit Code: 0 Output: 2025-02-23 03:15:50 (44312): Command: VBoxManage -q storagectl "boinc_8c9c2797e3f42766" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-23 03:15:50 (44312): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 03:15:51 (44312): Command: VBoxManage -q storageattach "boinc_8c9c2797e3f42766" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-23 03:15:51 (44312): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 03:15:52 (44312): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 03:15:53 (44312): Command: VBoxManage -q storageattach "boinc_8c9c2797e3f42766" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 03:15:53 (44312): Command: VBoxManage -q storageattach "boinc_8c9c2797e3f42766" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-23 03:15:53 (44312): Command: VBoxManage -q storageattach "boinc_8c9c2797e3f42766" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 03:15:54 (44312): Command: VBoxManage -q storageattach "boinc_8c9c2797e3f42766" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-23 03:15:54 (44312): Command: VBoxManage -q bandwidthctl "boinc_8c9c2797e3f42766" add "boinc_8c9c2797e3f42766_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-23 03:15:54 (44312): Command: VBoxManage -q modifyvm "boinc_8c9c2797e3f42766" --natpf1 ",tcp,127.0.0.1,53117,,80" Exit Code: 0 Output: 2025-02-23 03:15:54 (44312): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-23 03:15:55 (44312): Command: VBoxManage -q sharedfolder add "boinc_8c9c2797e3f42766" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\10/shared" Exit Code: 0 Output: 2025-02-23 03:15:56 (44312): Command: VBoxManage -q startvm "boinc_8c9c2797e3f42766" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_8c9c2797e3f42766' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\10\boinc_8c9c2797e3f42766\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_8c9c2797e3f42766" to power on... 2025-02-23 03:15:56 (44312): Command: VBoxManage -q snapshot "boinc_8c9c2797e3f42766" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-23 03:15:56 (44312): Command: VBoxManage -q bandwidthctl "boinc_8c9c2797e3f42766" remove "boinc_8c9c2797e3f42766_net" Exit Code: 0 Output: 2025-02-23 03:15:56 (44312): Command: VBoxManage -q unregistervm "boinc_8c9c2797e3f42766" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 03:16:02 (44312): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN