Name hBgMDmYGF66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmwnuKDmMKiOFo_0
Workunit 230519773
Created 23 Feb 2025, 0:43:25 UTC
Sent 23 Feb 2025, 6:33:22 UTC
Report deadline 3 Mar 2025, 6:33:22 UTC
Received 23 Feb 2025, 6:37:07 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10849823
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 41.52 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 14.06 MB
Peak swap size 3.27 MB
Peak disk usage 326.62 MB

Stderr output

<core_client_version>8.0.4</core_client_version>
<![CDATA[
<message>
Unzul�ssige Funktion.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-23 07:34:01 (3540): Detected: vboxwrapper 26206
2025-02-23 07:34:01 (3540): Detected: BOINC client v8.0.4
2025-02-23 07:34:02 (3540): Detected: VirtualBox VboxManage Interface (Version: 7.0.20)
2025-02-23 07:34:02 (3540): Successfully copied 'init_data.xml' to the shared directory.
2025-02-23 07:34:02 (3540): Create VM. (boinc_3da50c88d1cda7c0, slot#0)
2025-02-23 07:34:03 (3540): Setting Memory Size for VM. (4800MB)
2025-02-23 07:34:04 (3540): Setting CPU Count for VM. (8)
2025-02-23 07:34:04 (3540): Setting Chipset Options for VM.
2025-02-23 07:34:04 (3540): Setting Graphics Controller Options for VM.
2025-02-23 07:34:05 (3540): Setting Boot Options for VM.
2025-02-23 07:34:05 (3540): Setting Network Configuration for NAT.
2025-02-23 07:34:05 (3540): Enabling VM Network Access.
2025-02-23 07:34:05 (3540): Disabling USB Support for VM.
2025-02-23 07:34:06 (3540): Disabling COM Port Support for VM.
2025-02-23 07:34:06 (3540): Disabling LPT Port Support for VM.
2025-02-23 07:34:06 (3540): Disabling Audio Support for VM.
2025-02-23 07:34:06 (3540): Disabling Clipboard Support for VM.
2025-02-23 07:34:07 (3540): Disabling Drag and Drop Support for VM.
2025-02-23 07:34:07 (3540): Adding storage controller(s) to VM.
2025-02-23 07:34:07 (3540): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-23 07:34:10 (3540): Adding VirtualBox Guest Additions to VM.
2025-02-23 07:34:10 (3540): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-23 07:34:11 (3540): forwarding host port 54157 to guest port 80
2025-02-23 07:34:11 (3540): Enabling remote desktop for VM.
2025-02-23 07:34:11 (3540): Required extension pack not installed, remote desktop not enabled.
2025-02-23 07:34:11 (3540): Enabling shared directory for VM.
2025-02-23 07:34:12 (3540): Starting VM using VBoxManage interface. (boinc_3da50c88d1cda7c0, slot#0)
2025-02-23 07:34:12 (3540): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_3da50c88d1cda7c0" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_3da50c88d1cda7c0' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_3da50c88d1cda7c0" to power on...

2025-02-23 07:34:12 (3540): VM failed to start.
2025-02-23 07:34:12 (3540): Could not start 
2025-02-23 07:34:12 (3540): ERROR: VM failed to start
2025-02-23 07:34:12 (3540): Powering off VM.
2025-02-23 07:34:12 (3540): Deregistering VM. (boinc_3da50c88d1cda7c0, slot#0)
2025-02-23 07:34:12 (3540): Removing network bandwidth throttle group from VM.
2025-02-23 07:34:12 (3540): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:08.102201          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.102343          Saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.108066          Finished saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml"
00:00:08.108398          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:08.113210          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:08.365385          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:08.370510          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:08.634361          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.634933          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:08.639270          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:08.639473          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.641178          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:08.645522          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:08.646025          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:08.650510          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:08.898132          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.899359          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.899485          Saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.903708          Finished saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml"
00:00:08.903970          Saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.908253          Finished saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml"
00:00:08.908639          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:08.912744          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:09.167041          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:09.171533          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:09.423046          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:09.427431          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:09.949656          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:09.953718          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:10.213605          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:10.217876          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.217941          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.223784          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.480480          Launched VM: 3743591520 pid: 21640 (0x5488) frontend: headless name: boinc_3da50c88d1cda7c0
00:00:10.883354 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_3da50c88d1cda7c0' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.883760 Watcher  Reaper: Pid 21640 (0x5488) exited normally: 1 (0x1)
00:00:10.979272          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.070834          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox" with version "1.19-windows"
00:00:11.074671          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox"
00:00:11.343071          Saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.347553          Finished saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml"
00:00:11.347616          Saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.351227          Finished saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml"
00:00:11.352136 DeleteVM Saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.356347 DeleteVM Finished saving settings file "C:\Users\Sandy\.VirtualBox\VirtualBox.xml"
00:00:16.371527 main     VirtualBox: object deletion starts
00:00:16.372299 main     HostDnsMonitor: shutting down ...
00:00:16.372331 main     HostDnsMonitor: shut down
00:00:16.373323 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.373497 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

age -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 201 of file VBoxManageDisk.cpp

2025-02-23 07:34:03 (3540): 
Command: VBoxManage -q createvm --name "boinc_3da50c88d1cda7c0" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_3da50c88d1cda7c0' is created and registered.
UUID: 61b3ebd8-fe62-48bc-90b6-c53c6cc88d66
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\boinc_3da50c88d1cda7c0.vbox'

2025-02-23 07:34:03 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --description "hBgMDmYGF66nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmwnuKDmMKiOFo_0" 
Exit Code: 0
Output:

2025-02-23 07:34:04 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --memory 4800 
Exit Code: 0
Output:

2025-02-23 07:34:04 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --cpus 8 
Exit Code: 0
Output:

2025-02-23 07:34:04 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-23 07:34:05 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-23 07:34:05 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-23 07:34:05 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-23 07:34:05 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-23 07:34:06 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --usb off 
Exit Code: 0
Output:

2025-02-23 07:34:06 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-23 07:34:06 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-23 07:34:06 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-23 07:34:07 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --clipboard disabled 
Exit Code: 0
Output:

2025-02-23 07:34:07 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-23 07:34:07 (3540): 
Command: VBoxManage -q storagectl "boinc_3da50c88d1cda7c0" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-23 07:34:07 (3540): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-23 07:34:08 (3540): 
Command: VBoxManage -q storageattach "boinc_3da50c88d1cda7c0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-23 07:34:08 (3540): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-23 07:34:09 (3540): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-23 07:34:09 (3540): 
Command: VBoxManage -q storageattach "boinc_3da50c88d1cda7c0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-23 07:34:10 (3540): 
Command: VBoxManage -q storageattach "boinc_3da50c88d1cda7c0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-23 07:34:10 (3540): 
Command: VBoxManage -q storageattach "boinc_3da50c88d1cda7c0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-23 07:34:10 (3540): 
Command: VBoxManage -q storageattach "boinc_3da50c88d1cda7c0" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-23 07:34:11 (3540): 
Command: VBoxManage -q bandwidthctl "boinc_3da50c88d1cda7c0" add "boinc_3da50c88d1cda7c0_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-23 07:34:11 (3540): 
Command: VBoxManage -q modifyvm "boinc_3da50c88d1cda7c0" --natpf1 ",tcp,127.0.0.1,54157,,80" 
Exit Code: 0
Output:

2025-02-23 07:34:11 (3540): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-23 07:34:11 (3540): 
Command: VBoxManage -q sharedfolder add "boinc_3da50c88d1cda7c0" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2025-02-23 07:34:12 (3540): 
Command: VBoxManage -q startvm "boinc_3da50c88d1cda7c0" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_3da50c88d1cda7c0' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_3da50c88d1cda7c0\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_3da50c88d1cda7c0" to power on...

2025-02-23 07:34:12 (3540): 
Command: VBoxManage -q snapshot "boinc_3da50c88d1cda7c0" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-23 07:34:12 (3540): 
Command: VBoxManage -q bandwidthctl "boinc_3da50c88d1cda7c0" remove "boinc_3da50c88d1cda7c0_net" 
Exit Code: 0
Output:

2025-02-23 07:34:13 (3540): 
Command: VBoxManage -q unregistervm "boinc_3da50c88d1cda7c0" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

07:34:18 (3540): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN