Name | 5zOODm1T256nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmdttKDmNySKCn_1 |
Workunit | 230510285 |
Created | 22 Feb 2025, 17:05:38 UTC |
Sent | 22 Feb 2025, 22:01:09 UTC |
Report deadline | 2 Mar 2025, 22:01:09 UTC |
Received | 22 Feb 2025, 23:27:43 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10863068 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 36.67 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 10.95 MB |
Peak swap size | 2.05 MB |
Peak disk usage | 327.13 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-23 01:10:02 (13956): Detected: vboxwrapper 26206 2025-02-23 01:10:02 (13956): Detected: BOINC client v8.0.2 2025-02-23 01:10:03 (13956): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-23 01:10:03 (13956): Successfully copied 'init_data.xml' to the shared directory. 2025-02-23 01:10:03 (13956): Create VM. (boinc_533446770b223c92, slot#1) 2025-02-23 01:10:04 (13956): Setting Memory Size for VM. (4600MB) 2025-02-23 01:10:04 (13956): Setting CPU Count for VM. (6) 2025-02-23 01:10:04 (13956): Setting Chipset Options for VM. 2025-02-23 01:10:05 (13956): Setting Graphics Controller Options for VM. 2025-02-23 01:10:05 (13956): Setting Boot Options for VM. 2025-02-23 01:10:05 (13956): Setting Network Configuration for NAT. 2025-02-23 01:10:06 (13956): Enabling VM Network Access. 2025-02-23 01:10:06 (13956): Disabling USB Support for VM. 2025-02-23 01:10:06 (13956): Disabling COM Port Support for VM. 2025-02-23 01:10:06 (13956): Disabling LPT Port Support for VM. 2025-02-23 01:10:07 (13956): Disabling Audio Support for VM. 2025-02-23 01:10:07 (13956): Disabling Clipboard Support for VM. 2025-02-23 01:10:07 (13956): Disabling Drag and Drop Support for VM. 2025-02-23 01:10:07 (13956): Adding storage controller(s) to VM. 2025-02-23 01:10:08 (13956): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-23 01:10:10 (13956): Adding VirtualBox Guest Additions to VM. 2025-02-23 01:10:11 (13956): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-23 01:10:11 (13956): forwarding host port 50417 to guest port 80 2025-02-23 01:10:11 (13956): Enabling remote desktop for VM. 2025-02-23 01:10:12 (13956): Required extension pack not installed, remote desktop not enabled. 2025-02-23 01:10:12 (13956): Enabling shared directory for VM. 2025-02-23 01:10:12 (13956): Starting VM using VBoxManage interface. (boinc_533446770b223c92, slot#1) 2025-02-23 01:10:12 (13956): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_533446770b223c92" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_533446770b223c92' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_533446770b223c92" to power on... 2025-02-23 01:10:12 (13956): VM failed to start. 2025-02-23 01:10:12 (13956): Could not start 2025-02-23 01:10:12 (13956): ERROR: VM failed to start 2025-02-23 01:10:12 (13956): Powering off VM. 2025-02-23 01:10:12 (13956): Deregistering VM. (boinc_533446770b223c92, slot#1) 2025-02-23 01:10:12 (13956): Removing network bandwidth throttle group from VM. 2025-02-23 01:10:13 (13956): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.592239 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.592365 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.596708 Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" 00:00:07.596956 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:07.602361 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:07.845159 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:07.852282 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:08.113848 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.114278 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:08.119448 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:08.119537 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.120812 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:08.125713 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:08.125986 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:08.131595 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:08.368854 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.369643 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.369758 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.374084 Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" 00:00:08.374226 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.376522 Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" 00:00:08.376726 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:08.381999 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:08.622479 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:08.627918 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:08.894869 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:08.902086 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:09.432290 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:09.437913 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:09.698237 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.703797 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.703863 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.710447 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.966769 Launched VM: 3745618192 pid: 12560 (0x3110) frontend: headless name: boinc_533446770b223c92 00:00:10.285736 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_533446770b223c92' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.286037 Watcher Reaper: Pid 12560 (0x3110) exited normally: 1 (0x1) 00:00:10.316368 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.342080 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" with version "1.19-windows" 00:00:10.349208 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox" 00:00:10.600072 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.602719 Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" 00:00:10.602766 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.605378 Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" 00:00:10.605841 DeleteVM Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.608192 DeleteVM Finished saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" 00:00:15.615442 main VirtualBox: object deletion starts 00:00:15.616011 main HostDnsMonitor: shutting down ... 00:00:15.616031 main HostDnsMonitor: shut down 00:00:15.616790 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.616924 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-23 01:10:04 (13956): Command: VBoxManage -q createvm --name "boinc_533446770b223c92" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_533446770b223c92' is created and registered. UUID: fe39be79-dd99-460b-b6d8-648f80502a27 Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\boinc_533446770b223c92.vbox' 2025-02-23 01:10:04 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --description "5zOODm1T256nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmdttKDmNySKCn_1" Exit Code: 0 Output: 2025-02-23 01:10:04 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --memory 4600 Exit Code: 0 Output: 2025-02-23 01:10:04 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --cpus 6 Exit Code: 0 Output: 2025-02-23 01:10:05 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-23 01:10:05 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-23 01:10:05 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-23 01:10:06 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-23 01:10:06 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --cableconnected1 on Exit Code: 0 Output: 2025-02-23 01:10:06 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --usb off Exit Code: 0 Output: 2025-02-23 01:10:06 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-23 01:10:07 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-23 01:10:07 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-23 01:10:07 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --clipboard disabled Exit Code: 0 Output: 2025-02-23 01:10:07 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --draganddrop disabled Exit Code: 0 Output: 2025-02-23 01:10:08 (13956): Command: VBoxManage -q storagectl "boinc_533446770b223c92" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-23 01:10:08 (13956): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 01:10:08 (13956): Command: VBoxManage -q storageattach "boinc_533446770b223c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-23 01:10:08 (13956): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 01:10:10 (13956): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-23 01:10:10 (13956): Command: VBoxManage -q storageattach "boinc_533446770b223c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 01:10:10 (13956): Command: VBoxManage -q storageattach "boinc_533446770b223c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-23 01:10:10 (13956): Command: VBoxManage -q storageattach "boinc_533446770b223c92" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-23 01:10:11 (13956): Command: VBoxManage -q storageattach "boinc_533446770b223c92" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-23 01:10:11 (13956): Command: VBoxManage -q bandwidthctl "boinc_533446770b223c92" add "boinc_533446770b223c92_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-23 01:10:11 (13956): Command: VBoxManage -q modifyvm "boinc_533446770b223c92" --natpf1 ",tcp,127.0.0.1,50417,,80" Exit Code: 0 Output: 2025-02-23 01:10:12 (13956): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-23 01:10:12 (13956): Command: VBoxManage -q sharedfolder add "boinc_533446770b223c92" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-02-23 01:10:12 (13956): Command: VBoxManage -q startvm "boinc_533446770b223c92" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_533446770b223c92' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_533446770b223c92\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_533446770b223c92" to power on... 2025-02-23 01:10:12 (13956): Command: VBoxManage -q snapshot "boinc_533446770b223c92" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-23 01:10:13 (13956): Command: VBoxManage -q bandwidthctl "boinc_533446770b223c92" remove "boinc_533446770b223c92_net" Exit Code: 0 Output: 2025-02-23 01:10:13 (13956): Command: VBoxManage -q unregistervm "boinc_533446770b223c92" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 01:10:18 (13956): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN