Name mIZNDmix556nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmgAuKDmHaA1Im_0
Workunit 230512447
Created 22 Feb 2025, 14:47:18 UTC
Sent 22 Feb 2025, 19:21:29 UTC
Report deadline 2 Mar 2025, 19:21:29 UTC
Received 22 Feb 2025, 21:29:10 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10848453
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 27.33 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 8.29 MB
Peak swap size 2.05 MB
Peak disk usage 328.65 MB

Stderr output

<core_client_version>8.0.4</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-22 14:28:10 (6976): Detected: vboxwrapper 26206
2025-02-22 14:28:10 (6976): Detected: BOINC client v8.0.4
2025-02-22 14:28:11 (6976): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-22 14:28:11 (6976): Successfully copied 'init_data.xml' to the shared directory.
2025-02-22 14:28:12 (6976): Create VM. (boinc_f393ce997e25abf9, slot#11)
2025-02-22 14:28:12 (6976): Setting Memory Size for VM. (4800MB)
2025-02-22 14:28:13 (6976): Setting CPU Count for VM. (8)
2025-02-22 14:28:13 (6976): Setting Chipset Options for VM.
2025-02-22 14:28:13 (6976): Setting Graphics Controller Options for VM.
2025-02-22 14:28:13 (6976): Setting Boot Options for VM.
2025-02-22 14:28:14 (6976): Setting Network Configuration for NAT.
2025-02-22 14:28:14 (6976): Enabling VM Network Access.
2025-02-22 14:28:14 (6976): Disabling USB Support for VM.
2025-02-22 14:28:14 (6976): Disabling COM Port Support for VM.
2025-02-22 14:28:15 (6976): Disabling LPT Port Support for VM.
2025-02-22 14:28:15 (6976): Disabling Audio Support for VM.
2025-02-22 14:28:15 (6976): Disabling Clipboard Support for VM.
2025-02-22 14:28:16 (6976): Disabling Drag and Drop Support for VM.
2025-02-22 14:28:16 (6976): Adding storage controller(s) to VM.
2025-02-22 14:28:16 (6976): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-22 14:28:19 (6976): Adding VirtualBox Guest Additions to VM.
2025-02-22 14:28:19 (6976): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-22 14:28:20 (6976): forwarding host port 55206 to guest port 80
2025-02-22 14:28:20 (6976): Enabling remote desktop for VM.
2025-02-22 14:28:20 (6976): Required extension pack not installed, remote desktop not enabled.
2025-02-22 14:28:20 (6976): Enabling shared directory for VM.
2025-02-22 14:28:21 (6976): Starting VM using VBoxManage interface. (boinc_f393ce997e25abf9, slot#11)
2025-02-22 14:28:21 (6976): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_f393ce997e25abf9" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_f393ce997e25abf9' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_f393ce997e25abf9" to power on...

2025-02-22 14:28:21 (6976): VM failed to start.
2025-02-22 14:28:21 (6976): Could not start 
2025-02-22 14:28:21 (6976): ERROR: VM failed to start
2025-02-22 14:28:21 (6976): Powering off VM.
2025-02-22 14:28:21 (6976): Deregistering VM. (boinc_f393ce997e25abf9, slot#11)
2025-02-22 14:28:21 (6976): Removing network bandwidth throttle group from VM.
2025-02-22 14:28:22 (6976): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:08.228816          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:08.234129          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:08.520056          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.521926          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:08.529916          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:08.530596          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.538383          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:08.545212          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:08.548770          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:08.560983          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:08.779283          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.781873          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.782151          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.791999          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:08.793847          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.802076          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:08.803081          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:08.809848          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:09.046027          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:09.056194          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:09.331530          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:09.338793          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:09.862933          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:09.869685          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:10.139670          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:10.157934          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.158221          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.178803          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.405317          Launched VM: 2512553568 pid: 8364 (0x20ac) frontend: headless name: boinc_f393ce997e25abf9
00:00:10.918334 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_f393ce997e25abf9' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.919632 Watcher  Reaper: Pid 8364 (0x20ac) exited normally: 1 (0x1)
00:00:11.052161          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.179740          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox" with version "1.19-windows"
00:00:11.186748          Finished saving settings file "C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox"
00:00:11.445687          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.453480          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:11.453700          Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.460792          Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:11.463605 DeleteVM Saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.472197 DeleteVM Finished saving settings file "C:\Users\Hilda\.VirtualBox\VirtualBox.xml"
00:00:16.485848 main     VirtualBox: object deletion starts
00:00:16.485950 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\Hilda\VirtualBox VMs\Montana-AMD\Snapshots/{6eb7b533-a2f9-44ed-85bd-176ecdeefdbe}.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:16.486014 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\Hilda\VirtualBox VMs\Montana-AMD\Montana-AMD.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:16.487493 main     ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={6cc49055-dad4-4496-85cf-3f76bcb3b5fa} aComponent={SnapshotWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.489083 main     HostDnsMonitor: shutting down ...
00:00:16.489175 main     HostDnsMonitor: shut down
00:00:16.492287 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.492622 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

 showhdinfo "C:\ProgramData\BOINC\slots\11/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\11\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-22 14:28:12 (6976): 
Command: VBoxManage -q createvm --name "boinc_f393ce997e25abf9" --basefolder "C:\ProgramData\BOINC\slots\11" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_f393ce997e25abf9' is created and registered.
UUID: cfe41bc1-5c07-41a5-96b5-202a50b45b18
Settings file: 'C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\boinc_f393ce997e25abf9.vbox'

2025-02-22 14:28:12 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --description "mIZNDmix556nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmgAuKDmHaA1Im_0" 
Exit Code: 0
Output:

2025-02-22 14:28:13 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --memory 4800 
Exit Code: 0
Output:

2025-02-22 14:28:13 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --cpus 8 
Exit Code: 0
Output:

2025-02-22 14:28:13 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-22 14:28:13 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-22 14:28:14 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-22 14:28:14 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-22 14:28:14 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-22 14:28:14 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --usb off 
Exit Code: 0
Output:

2025-02-22 14:28:15 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-22 14:28:15 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-22 14:28:15 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-22 14:28:16 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --clipboard disabled 
Exit Code: 0
Output:

2025-02-22 14:28:16 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-22 14:28:16 (6976): 
Command: VBoxManage -q storagectl "boinc_f393ce997e25abf9" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-22 14:28:16 (6976): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 14:28:17 (6976): 
Command: VBoxManage -q storageattach "boinc_f393ce997e25abf9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-22 14:28:17 (6976): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 14:28:18 (6976): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 14:28:18 (6976): 
Command: VBoxManage -q storageattach "boinc_f393ce997e25abf9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 14:28:19 (6976): 
Command: VBoxManage -q storageattach "boinc_f393ce997e25abf9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-22 14:28:19 (6976): 
Command: VBoxManage -q storageattach "boinc_f393ce997e25abf9" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 14:28:19 (6976): 
Command: VBoxManage -q storageattach "boinc_f393ce997e25abf9" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-22 14:28:20 (6976): 
Command: VBoxManage -q bandwidthctl "boinc_f393ce997e25abf9" add "boinc_f393ce997e25abf9_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-22 14:28:20 (6976): 
Command: VBoxManage -q modifyvm "boinc_f393ce997e25abf9" --natpf1 ",tcp,127.0.0.1,55206,,80" 
Exit Code: 0
Output:

2025-02-22 14:28:20 (6976): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-22 14:28:20 (6976): 
Command: VBoxManage -q sharedfolder add "boinc_f393ce997e25abf9" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\11/shared"
Exit Code: 0
Output:

2025-02-22 14:28:21 (6976): 
Command: VBoxManage -q startvm "boinc_f393ce997e25abf9" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_f393ce997e25abf9' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\11\boinc_f393ce997e25abf9\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_f393ce997e25abf9" to power on...

2025-02-22 14:28:21 (6976): 
Command: VBoxManage -q snapshot "boinc_f393ce997e25abf9" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-22 14:28:22 (6976): 
Command: VBoxManage -q bandwidthctl "boinc_f393ce997e25abf9" remove "boinc_f393ce997e25abf9_net" 
Exit Code: 0
Output:

2025-02-22 14:28:22 (6976): 
Command: VBoxManage -q unregistervm "boinc_f393ce997e25abf9" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

14:28:27 (6976): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN