Name | z0rNDmcA456n9Rq4apOajLDm4fhM0noT9bVoFjIUDmLFeKDmuJmVZm_0 |
Workunit | 230511331 |
Created | 22 Feb 2025, 12:52:28 UTC |
Sent | 22 Feb 2025, 17:31:56 UTC |
Report deadline | 2 Mar 2025, 17:31:56 UTC |
Received | 22 Feb 2025, 17:34:34 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10869666 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 6.00 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.95 MB |
Peak swap size | 2.01 MB |
Peak disk usage | 329.27 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-22 12:32:20 (21216): Detected: vboxwrapper 26206 2025-02-22 12:32:20 (21216): Detected: BOINC client v8.0.4 2025-02-22 12:32:21 (21216): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-22 12:32:21 (21216): Successfully copied 'init_data.xml' to the shared directory. 2025-02-22 12:32:22 (21216): Create VM. (boinc_aa500c0e42dcfd4a, slot#0) 2025-02-22 12:32:22 (21216): Setting Memory Size for VM. (4600MB) 2025-02-22 12:32:23 (21216): Setting CPU Count for VM. (6) 2025-02-22 12:32:23 (21216): Setting Chipset Options for VM. 2025-02-22 12:32:23 (21216): Setting Graphics Controller Options for VM. 2025-02-22 12:32:23 (21216): Setting Boot Options for VM. 2025-02-22 12:32:24 (21216): Setting Network Configuration for NAT. 2025-02-22 12:32:24 (21216): Enabling VM Network Access. 2025-02-22 12:32:24 (21216): Disabling USB Support for VM. 2025-02-22 12:32:24 (21216): Disabling COM Port Support for VM. 2025-02-22 12:32:25 (21216): Disabling LPT Port Support for VM. 2025-02-22 12:32:25 (21216): Disabling Audio Support for VM. 2025-02-22 12:32:25 (21216): Disabling Clipboard Support for VM. 2025-02-22 12:32:25 (21216): Disabling Drag and Drop Support for VM. 2025-02-22 12:32:26 (21216): Adding storage controller(s) to VM. 2025-02-22 12:32:26 (21216): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-22 12:32:29 (21216): Adding VirtualBox Guest Additions to VM. 2025-02-22 12:32:29 (21216): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-22 12:32:29 (21216): forwarding host port 53013 to guest port 80 2025-02-22 12:32:30 (21216): Enabling remote desktop for VM. 2025-02-22 12:32:30 (21216): Required extension pack not installed, remote desktop not enabled. 2025-02-22 12:32:30 (21216): Enabling shared directory for VM. 2025-02-22 12:32:30 (21216): Starting VM using VBoxManage interface. (boinc_aa500c0e42dcfd4a, slot#0) 2025-02-22 12:32:31 (21216): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_aa500c0e42dcfd4a" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_aa500c0e42dcfd4a' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_aa500c0e42dcfd4a" to power on... 2025-02-22 12:32:31 (21216): VM failed to start. 2025-02-22 12:32:31 (21216): Could not start 2025-02-22 12:32:31 (21216): ERROR: VM failed to start 2025-02-22 12:32:31 (21216): Powering off VM. 2025-02-22 12:32:31 (21216): Deregistering VM. (boinc_aa500c0e42dcfd4a, slot#0) 2025-02-22 12:32:31 (21216): Removing network bandwidth throttle group from VM. 2025-02-22 12:32:31 (21216): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.562732 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.562833 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.567645 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:07.567961 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:07.569122 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:07.826782 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:07.829967 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:08.092120 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.092371 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:08.095366 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:08.095529 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.097220 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:08.098689 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:08.099211 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:08.100813 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:08.358037 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.358606 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.358683 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.360959 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:08.361309 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.362987 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:08.363347 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:08.365091 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:08.624664 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:08.625755 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:08.896393 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:08.897969 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:09.416171 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:09.417587 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:09.680822 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.684075 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.684132 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.687048 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.945967 Launched VM: 4243815600 pid: 19308 (0x4b6c) frontend: headless name: boinc_aa500c0e42dcfd4a 00:00:10.306548 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_aa500c0e42dcfd4a' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.306956 Watcher Reaper: Pid 19308 (0x4b6c) exited normally: 1 (0x1) 00:00:10.342054 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.369944 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" with version "1.19-windows" 00:00:10.371143 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox" 00:00:10.633380 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.635813 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:10.635855 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.637113 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:10.637652 DeleteVM Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.639442 DeleteVM Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:15.649310 main VirtualBox: object deletion starts 00:00:15.649833 main HostDnsMonitor: shutting down ... 00:00:15.649860 main HostDnsMonitor: shut down 00:00:15.651342 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.651503 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-22 12:32:22 (21216): Command: VBoxManage -q createvm --name "boinc_aa500c0e42dcfd4a" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_aa500c0e42dcfd4a' is created and registered. UUID: e36da533-1828-462e-a3ec-4e7dd209b88d Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\boinc_aa500c0e42dcfd4a.vbox' 2025-02-22 12:32:22 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --description "z0rNDmcA456n9Rq4apOajLDm4fhM0noT9bVoFjIUDmLFeKDmuJmVZm_0" Exit Code: 0 Output: 2025-02-22 12:32:23 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --memory 4600 Exit Code: 0 Output: 2025-02-22 12:32:23 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --cpus 6 Exit Code: 0 Output: 2025-02-22 12:32:23 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-22 12:32:23 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-22 12:32:24 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-22 12:32:24 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-22 12:32:24 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --cableconnected1 on Exit Code: 0 Output: 2025-02-22 12:32:24 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --usb off Exit Code: 0 Output: 2025-02-22 12:32:25 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-22 12:32:25 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-22 12:32:25 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-22 12:32:25 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --clipboard disabled Exit Code: 0 Output: 2025-02-22 12:32:26 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --draganddrop disabled Exit Code: 0 Output: 2025-02-22 12:32:26 (21216): Command: VBoxManage -q storagectl "boinc_aa500c0e42dcfd4a" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-22 12:32:26 (21216): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 12:32:26 (21216): Command: VBoxManage -q storageattach "boinc_aa500c0e42dcfd4a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-22 12:32:27 (21216): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 12:32:28 (21216): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 12:32:28 (21216): Command: VBoxManage -q storageattach "boinc_aa500c0e42dcfd4a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 12:32:29 (21216): Command: VBoxManage -q storageattach "boinc_aa500c0e42dcfd4a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-22 12:32:29 (21216): Command: VBoxManage -q storageattach "boinc_aa500c0e42dcfd4a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 12:32:29 (21216): Command: VBoxManage -q storageattach "boinc_aa500c0e42dcfd4a" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-22 12:32:29 (21216): Command: VBoxManage -q bandwidthctl "boinc_aa500c0e42dcfd4a" add "boinc_aa500c0e42dcfd4a_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-22 12:32:30 (21216): Command: VBoxManage -q modifyvm "boinc_aa500c0e42dcfd4a" --natpf1 ",tcp,127.0.0.1,53013,,80" Exit Code: 0 Output: 2025-02-22 12:32:30 (21216): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-22 12:32:30 (21216): Command: VBoxManage -q sharedfolder add "boinc_aa500c0e42dcfd4a" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-22 12:32:31 (21216): Command: VBoxManage -q startvm "boinc_aa500c0e42dcfd4a" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_aa500c0e42dcfd4a' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_aa500c0e42dcfd4a\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_aa500c0e42dcfd4a" to power on... 2025-02-22 12:32:31 (21216): Command: VBoxManage -q snapshot "boinc_aa500c0e42dcfd4a" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-22 12:32:31 (21216): Command: VBoxManage -q bandwidthctl "boinc_aa500c0e42dcfd4a" remove "boinc_aa500c0e42dcfd4a_net" Exit Code: 0 Output: 2025-02-22 12:32:31 (21216): Command: VBoxManage -q unregistervm "boinc_aa500c0e42dcfd4a" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 12:32:36 (21216): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN