Name | fTTMDmswt56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmdJtKDmTJxwLo_1 |
Workunit | 230504852 |
Created | 22 Feb 2025, 8:26:58 UTC |
Sent | 22 Feb 2025, 13:03:20 UTC |
Report deadline | 2 Mar 2025, 13:03:20 UTC |
Received | 22 Feb 2025, 13:05:47 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10870209 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 8.00 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 11.05 MB |
Peak swap size | 2.18 MB |
Peak disk usage | 326.38 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-22 08:03:59 (6280): Detected: vboxwrapper 26206 2025-02-22 08:03:59 (6280): Detected: BOINC client v8.0.4 2025-02-22 08:04:00 (6280): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-22 08:04:00 (6280): Successfully copied 'init_data.xml' to the shared directory. 2025-02-22 08:04:01 (6280): Create VM. (boinc_744b20978fc1463a, slot#0) 2025-02-22 08:04:01 (6280): Setting Memory Size for VM. (4800MB) 2025-02-22 08:04:02 (6280): Setting CPU Count for VM. (8) 2025-02-22 08:04:02 (6280): Setting Chipset Options for VM. 2025-02-22 08:04:02 (6280): Setting Graphics Controller Options for VM. 2025-02-22 08:04:02 (6280): Setting Boot Options for VM. 2025-02-22 08:04:03 (6280): Setting Network Configuration for NAT. 2025-02-22 08:04:03 (6280): Enabling VM Network Access. 2025-02-22 08:04:03 (6280): Disabling USB Support for VM. 2025-02-22 08:04:04 (6280): Disabling COM Port Support for VM. 2025-02-22 08:04:04 (6280): Disabling LPT Port Support for VM. 2025-02-22 08:04:04 (6280): Disabling Audio Support for VM. 2025-02-22 08:04:04 (6280): Disabling Clipboard Support for VM. 2025-02-22 08:04:05 (6280): Disabling Drag and Drop Support for VM. 2025-02-22 08:04:05 (6280): Adding storage controller(s) to VM. 2025-02-22 08:04:05 (6280): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-22 08:04:08 (6280): Adding VirtualBox Guest Additions to VM. 2025-02-22 08:04:08 (6280): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-22 08:04:09 (6280): forwarding host port 50166 to guest port 80 2025-02-22 08:04:09 (6280): Enabling remote desktop for VM. 2025-02-22 08:04:09 (6280): Required extension pack not installed, remote desktop not enabled. 2025-02-22 08:04:09 (6280): Enabling shared directory for VM. 2025-02-22 08:04:10 (6280): Starting VM using VBoxManage interface. (boinc_744b20978fc1463a, slot#0) 2025-02-22 08:04:10 (6280): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_744b20978fc1463a" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_744b20978fc1463a' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_744b20978fc1463a" to power on... 2025-02-22 08:04:10 (6280): VM failed to start. 2025-02-22 08:04:10 (6280): Could not start 2025-02-22 08:04:10 (6280): ERROR: VM failed to start 2025-02-22 08:04:10 (6280): Powering off VM. 2025-02-22 08:04:10 (6280): Deregistering VM. (boinc_744b20978fc1463a, slot#0) 2025-02-22 08:04:10 (6280): Removing network bandwidth throttle group from VM. 2025-02-22 08:04:11 (6280): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.239187 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.239749 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.242881 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:08.243433 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:08.247197 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:08.506343 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:08.511476 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:08.774425 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.775444 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:08.779339 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:08.779541 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.781805 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:08.785157 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:08.785780 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:08.788914 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:09.042151 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.044556 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.044843 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.047756 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:09.048201 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.050495 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:09.050969 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:09.054072 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:09.304598 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:09.311803 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:09.577408 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:09.581741 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:10.113287 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:10.119447 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:10.372043 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.382184 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.382282 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.392346 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.671516 Launched VM: 2569654176 pid: 1600 (0x640) frontend: headless name: boinc_744b20978fc1463a 00:00:11.142019 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_744b20978fc1463a' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.143510 Watcher Reaper: Pid 1600 (0x640) exited normally: 1 (0x1) 00:00:11.245063 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.352109 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" with version "1.19-windows" 00:00:11.360774 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox" 00:00:11.606997 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.611720 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:11.611895 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.616760 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:11.618994 DeleteVM Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.624117 DeleteVM Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:16.655277 main VirtualBox: object deletion starts 00:00:16.659693 main HostDnsMonitor: shutting down ... 00:00:16.659861 main HostDnsMonitor: shut down 00:00:16.665127 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.665731 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: age -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-22 08:04:01 (6280): Command: VBoxManage -q createvm --name "boinc_744b20978fc1463a" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_744b20978fc1463a' is created and registered. UUID: 2abb02de-af55-4de8-a51b-4d1454ca28c7 Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\boinc_744b20978fc1463a.vbox' 2025-02-22 08:04:01 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --description "fTTMDmswt56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmdJtKDmTJxwLo_1" Exit Code: 0 Output: 2025-02-22 08:04:02 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --memory 4800 Exit Code: 0 Output: 2025-02-22 08:04:02 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --cpus 8 Exit Code: 0 Output: 2025-02-22 08:04:02 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-22 08:04:02 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-22 08:04:03 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-22 08:04:03 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-22 08:04:03 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --cableconnected1 on Exit Code: 0 Output: 2025-02-22 08:04:04 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --usb off Exit Code: 0 Output: 2025-02-22 08:04:04 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-22 08:04:04 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-22 08:04:04 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-22 08:04:05 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --clipboard disabled Exit Code: 0 Output: 2025-02-22 08:04:05 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --draganddrop disabled Exit Code: 0 Output: 2025-02-22 08:04:05 (6280): Command: VBoxManage -q storagectl "boinc_744b20978fc1463a" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-22 08:04:05 (6280): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 08:04:06 (6280): Command: VBoxManage -q storageattach "boinc_744b20978fc1463a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-22 08:04:06 (6280): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 08:04:07 (6280): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 08:04:08 (6280): Command: VBoxManage -q storageattach "boinc_744b20978fc1463a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 08:04:08 (6280): Command: VBoxManage -q storageattach "boinc_744b20978fc1463a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-22 08:04:08 (6280): Command: VBoxManage -q storageattach "boinc_744b20978fc1463a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 08:04:08 (6280): Command: VBoxManage -q storageattach "boinc_744b20978fc1463a" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-22 08:04:09 (6280): Command: VBoxManage -q bandwidthctl "boinc_744b20978fc1463a" add "boinc_744b20978fc1463a_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-22 08:04:09 (6280): Command: VBoxManage -q modifyvm "boinc_744b20978fc1463a" --natpf1 ",tcp,127.0.0.1,50166,,80" Exit Code: 0 Output: 2025-02-22 08:04:09 (6280): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-22 08:04:09 (6280): Command: VBoxManage -q sharedfolder add "boinc_744b20978fc1463a" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-22 08:04:10 (6280): Command: VBoxManage -q startvm "boinc_744b20978fc1463a" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_744b20978fc1463a' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_744b20978fc1463a\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_744b20978fc1463a" to power on... 2025-02-22 08:04:10 (6280): Command: VBoxManage -q snapshot "boinc_744b20978fc1463a" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-22 08:04:11 (6280): Command: VBoxManage -q bandwidthctl "boinc_744b20978fc1463a" remove "boinc_744b20978fc1463a_net" Exit Code: 0 Output: 2025-02-22 08:04:11 (6280): Command: VBoxManage -q unregistervm "boinc_744b20978fc1463a" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 08:04:16 (6280): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN