Name BbmKDmOaz56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDm7htKDm66WBhn_0
Workunit 230508524
Created 22 Feb 2025, 7:58:51 UTC
Sent 22 Feb 2025, 13:05:47 UTC
Report deadline 2 Mar 2025, 13:05:47 UTC
Received 22 Feb 2025, 13:08:16 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10870209
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 8.00 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 7.74 MB
Peak swap size 2.03 MB
Peak disk usage 328.34 MB

Stderr output

<core_client_version>8.0.4</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-22 08:06:28 (8200): Detected: vboxwrapper 26206
2025-02-22 08:06:28 (8200): Detected: BOINC client v8.0.4
2025-02-22 08:06:29 (8200): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-22 08:06:29 (8200): Successfully copied 'init_data.xml' to the shared directory.
2025-02-22 08:06:30 (8200): Create VM. (boinc_3d6867812e65056f, slot#0)
2025-02-22 08:06:31 (8200): Setting Memory Size for VM. (4800MB)
2025-02-22 08:06:31 (8200): Setting CPU Count for VM. (8)
2025-02-22 08:06:31 (8200): Setting Chipset Options for VM.
2025-02-22 08:06:31 (8200): Setting Graphics Controller Options for VM.
2025-02-22 08:06:32 (8200): Setting Boot Options for VM.
2025-02-22 08:06:32 (8200): Setting Network Configuration for NAT.
2025-02-22 08:06:32 (8200): Enabling VM Network Access.
2025-02-22 08:06:32 (8200): Disabling USB Support for VM.
2025-02-22 08:06:33 (8200): Disabling COM Port Support for VM.
2025-02-22 08:06:33 (8200): Disabling LPT Port Support for VM.
2025-02-22 08:06:33 (8200): Disabling Audio Support for VM.
2025-02-22 08:06:34 (8200): Disabling Clipboard Support for VM.
2025-02-22 08:06:34 (8200): Disabling Drag and Drop Support for VM.
2025-02-22 08:06:34 (8200): Adding storage controller(s) to VM.
2025-02-22 08:06:34 (8200): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-22 08:06:37 (8200): Adding VirtualBox Guest Additions to VM.
2025-02-22 08:06:37 (8200): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-22 08:06:38 (8200): forwarding host port 50179 to guest port 80
2025-02-22 08:06:38 (8200): Enabling remote desktop for VM.
2025-02-22 08:06:38 (8200): Required extension pack not installed, remote desktop not enabled.
2025-02-22 08:06:38 (8200): Enabling shared directory for VM.
2025-02-22 08:06:39 (8200): Starting VM using VBoxManage interface. (boinc_3d6867812e65056f, slot#0)
2025-02-22 08:06:39 (8200): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_3d6867812e65056f" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_3d6867812e65056f' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_3d6867812e65056f" to power on...

2025-02-22 08:06:39 (8200): VM failed to start.
2025-02-22 08:06:39 (8200): Could not start 
2025-02-22 08:06:39 (8200): ERROR: VM failed to start
2025-02-22 08:06:39 (8200): Powering off VM.
2025-02-22 08:06:39 (8200): Deregistering VM. (boinc_3d6867812e65056f, slot#0)
2025-02-22 08:06:40 (8200): Removing network bandwidth throttle group from VM.
2025-02-22 08:06:40 (8200): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:08.240947          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.241264          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.244290          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:08.245363          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:08.250020          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:08.506999          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:08.511849          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:08.781763          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.783890          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:08.790126          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:08.790710          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.795605          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:08.799948          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:08.800854          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:08.804500          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:09.054077          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.057716          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.057987          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.060983          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:09.061551          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.065039          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:09.065688          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:09.069196          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:09.315220          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:09.320286          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:09.583582          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:09.587161          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:10.154156          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:10.160919          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:10.411813          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:10.425863          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.425980          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.436418          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.691211          Launched VM: 3926085392 pid: 1412 (0x584) frontend: headless name: boinc_3d6867812e65056f
00:00:11.141668 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_3d6867812e65056f' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:11.143072 Watcher  Reaper: Pid 1412 (0x584) exited normally: 1 (0x1)
00:00:11.259643          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.372500          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox" with version "1.19-windows"
00:00:11.402587          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox"
00:00:11.624939          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.629719          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:11.629896          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.634738          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:11.637007 DeleteVM Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.641641 DeleteVM Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:16.661158 main     VirtualBox: object deletion starts
00:00:16.665666 main     HostDnsMonitor: shutting down ...
00:00:16.665825 main     HostDnsMonitor: shut down
00:00:16.671066 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.671710 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

age -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-22 08:06:30 (8200): 
Command: VBoxManage -q createvm --name "boinc_3d6867812e65056f" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_3d6867812e65056f' is created and registered.
UUID: d9a397e6-ef30-49ab-98a9-b1a830e91fee
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\boinc_3d6867812e65056f.vbox'

2025-02-22 08:06:31 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --description "BbmKDmOaz56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDm7htKDm66WBhn_0" 
Exit Code: 0
Output:

2025-02-22 08:06:31 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --memory 4800 
Exit Code: 0
Output:

2025-02-22 08:06:31 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --cpus 8 
Exit Code: 0
Output:

2025-02-22 08:06:31 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-22 08:06:32 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-22 08:06:32 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-22 08:06:32 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-22 08:06:32 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-22 08:06:33 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --usb off 
Exit Code: 0
Output:

2025-02-22 08:06:33 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-22 08:06:33 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-22 08:06:34 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-22 08:06:34 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --clipboard disabled 
Exit Code: 0
Output:

2025-02-22 08:06:34 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-22 08:06:34 (8200): 
Command: VBoxManage -q storagectl "boinc_3d6867812e65056f" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-22 08:06:35 (8200): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 08:06:35 (8200): 
Command: VBoxManage -q storageattach "boinc_3d6867812e65056f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-22 08:06:35 (8200): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 08:06:36 (8200): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 08:06:37 (8200): 
Command: VBoxManage -q storageattach "boinc_3d6867812e65056f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 08:06:37 (8200): 
Command: VBoxManage -q storageattach "boinc_3d6867812e65056f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-22 08:06:37 (8200): 
Command: VBoxManage -q storageattach "boinc_3d6867812e65056f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 08:06:37 (8200): 
Command: VBoxManage -q storageattach "boinc_3d6867812e65056f" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-22 08:06:38 (8200): 
Command: VBoxManage -q bandwidthctl "boinc_3d6867812e65056f" add "boinc_3d6867812e65056f_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-22 08:06:38 (8200): 
Command: VBoxManage -q modifyvm "boinc_3d6867812e65056f" --natpf1 ",tcp,127.0.0.1,50179,,80" 
Exit Code: 0
Output:

2025-02-22 08:06:38 (8200): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-22 08:06:39 (8200): 
Command: VBoxManage -q sharedfolder add "boinc_3d6867812e65056f" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2025-02-22 08:06:39 (8200): 
Command: VBoxManage -q startvm "boinc_3d6867812e65056f" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_3d6867812e65056f' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_3d6867812e65056f\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_3d6867812e65056f" to power on...

2025-02-22 08:06:40 (8200): 
Command: VBoxManage -q snapshot "boinc_3d6867812e65056f" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-22 08:06:40 (8200): 
Command: VBoxManage -q bandwidthctl "boinc_3d6867812e65056f" remove "boinc_3d6867812e65056f_net" 
Exit Code: 0
Output:

2025-02-22 08:06:40 (8200): 
Command: VBoxManage -q unregistervm "boinc_3d6867812e65056f" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

08:06:45 (8200): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN