Name UhBNDmUOz56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmGhtKDmJBdL8n_0
Workunit 230508416
Created 22 Feb 2025, 7:46:38 UTC
Sent 22 Feb 2025, 12:25:41 UTC
Report deadline 2 Mar 2025, 12:25:41 UTC
Received 22 Feb 2025, 12:28:13 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10870209
Run time 18 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 8.00 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 7.79 MB
Peak swap size 2.02 MB
Peak disk usage 331.70 MB

Stderr output

<core_client_version>8.0.4</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-22 07:26:20 (8764): Detected: vboxwrapper 26206
2025-02-22 07:26:20 (8764): Detected: BOINC client v8.0.4
2025-02-22 07:26:21 (8764): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-22 07:26:22 (8764): Successfully copied 'init_data.xml' to the shared directory.
2025-02-22 07:26:22 (8764): Create VM. (boinc_d053f7ca915683cf, slot#0)
2025-02-22 07:26:23 (8764): Setting Memory Size for VM. (4800MB)
2025-02-22 07:26:23 (8764): Setting CPU Count for VM. (8)
2025-02-22 07:26:23 (8764): Setting Chipset Options for VM.
2025-02-22 07:26:24 (8764): Setting Graphics Controller Options for VM.
2025-02-22 07:26:24 (8764): Setting Boot Options for VM.
2025-02-22 07:26:24 (8764): Setting Network Configuration for NAT.
2025-02-22 07:26:24 (8764): Enabling VM Network Access.
2025-02-22 07:26:25 (8764): Disabling USB Support for VM.
2025-02-22 07:26:25 (8764): Disabling COM Port Support for VM.
2025-02-22 07:26:25 (8764): Disabling LPT Port Support for VM.
2025-02-22 07:26:25 (8764): Disabling Audio Support for VM.
2025-02-22 07:26:26 (8764): Disabling Clipboard Support for VM.
2025-02-22 07:26:26 (8764): Disabling Drag and Drop Support for VM.
2025-02-22 07:26:26 (8764): Adding storage controller(s) to VM.
2025-02-22 07:26:27 (8764): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-22 07:26:29 (8764): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-22 07:26:30 (8764): forwarding host port 49918 to guest port 80
2025-02-22 07:26:30 (8764): Enabling remote desktop for VM.
2025-02-22 07:26:30 (8764): Required extension pack not installed, remote desktop not enabled.
2025-02-22 07:26:30 (8764): Enabling shared directory for VM.
2025-02-22 07:26:31 (8764): Starting VM using VBoxManage interface. (boinc_d053f7ca915683cf, slot#0)
2025-02-22 07:26:31 (8764): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_d053f7ca915683cf" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_d053f7ca915683cf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_d053f7ca915683cf" to power on...

2025-02-22 07:26:31 (8764): VM failed to start.
2025-02-22 07:26:31 (8764): Could not start 
2025-02-22 07:26:31 (8764): ERROR: VM failed to start
2025-02-22 07:26:31 (8764): Powering off VM.
2025-02-22 07:26:31 (8764): Deregistering VM. (boinc_d053f7ca915683cf, slot#0)
2025-02-22 07:26:32 (8764): Removing network bandwidth throttle group from VM.
2025-02-22 07:26:32 (8764): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:06.413371          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.416316          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:07.978003          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.978743          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.979032          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.983540          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:07.984981          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:07.992835          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:08.230940          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:08.239021          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:08.499047          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.500479          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:08.506659          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:08.506998          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.509690          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:08.512956          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:08.513611          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:08.516826          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:08.774153          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:08.780864          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:09.048617          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:09.053808          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:09.581580          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:09.590502          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:09.828993          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:09.836692          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.836799          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.836959          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.837110          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.847541          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.125677          Launched VM: 363870720 pid: 13128 (0x3348) frontend: headless name: boinc_d053f7ca915683cf
00:00:10.666250 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_d053f7ca915683cf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.667684 Watcher  Reaper: Pid 13128 (0x3348) exited normally: 1 (0x1)
00:00:10.772266          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.851628          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox" with version "1.19-windows"
00:00:10.856786          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox"
00:00:11.109501          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.112095          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:11.112180          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.114394          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:11.115793 DeleteVM Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.120628 DeleteVM Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:16.136638 main     VirtualBox: object deletion starts
00:00:16.141355 main     HostDnsMonitor: shutting down ...
00:00:16.141562 main     HostDnsMonitor: shut down
00:00:16.146747 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.147216 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp

2025-02-22 07:26:22 (8764): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-22 07:26:22 (8764): 
Command: VBoxManage -q createvm --name "boinc_d053f7ca915683cf" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_d053f7ca915683cf' is created and registered.
UUID: bb329d41-6ee1-489f-ba69-946bbc7b1a59
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\boinc_d053f7ca915683cf.vbox'

2025-02-22 07:26:23 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --description "UhBNDmUOz56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmGhtKDmJBdL8n_0" 
Exit Code: 0
Output:

2025-02-22 07:26:23 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --memory 4800 
Exit Code: 0
Output:

2025-02-22 07:26:23 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --cpus 8 
Exit Code: 0
Output:

2025-02-22 07:26:24 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-22 07:26:24 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-22 07:26:24 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-22 07:26:24 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-22 07:26:25 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-22 07:26:25 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --usb off 
Exit Code: 0
Output:

2025-02-22 07:26:25 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-22 07:26:25 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-22 07:26:26 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-22 07:26:26 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --clipboard disabled 
Exit Code: 0
Output:

2025-02-22 07:26:26 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-22 07:26:27 (8764): 
Command: VBoxManage -q storagectl "boinc_d053f7ca915683cf" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-22 07:26:27 (8764): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 07:26:27 (8764): 
Command: VBoxManage -q storageattach "boinc_d053f7ca915683cf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-22 07:26:27 (8764): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 07:26:29 (8764): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 07:26:29 (8764): 
Command: VBoxManage -q storageattach "boinc_d053f7ca915683cf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 07:26:29 (8764): 
Command: VBoxManage -q storageattach "boinc_d053f7ca915683cf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-22 07:26:29 (8764): 
Command: VBoxManage -q storageattach "boinc_d053f7ca915683cf" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 07:26:30 (8764): 
Command: VBoxManage -q bandwidthctl "boinc_d053f7ca915683cf" add "boinc_d053f7ca915683cf_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-22 07:26:30 (8764): 
Command: VBoxManage -q modifyvm "boinc_d053f7ca915683cf" --natpf1 ",tcp,127.0.0.1,49918,,80" 
Exit Code: 0
Output:

2025-02-22 07:26:30 (8764): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-22 07:26:31 (8764): 
Command: VBoxManage -q sharedfolder add "boinc_d053f7ca915683cf" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2025-02-22 07:26:31 (8764): 
Command: VBoxManage -q startvm "boinc_d053f7ca915683cf" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_d053f7ca915683cf' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_d053f7ca915683cf\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_d053f7ca915683cf" to power on...

2025-02-22 07:26:32 (8764): 
Command: VBoxManage -q snapshot "boinc_d053f7ca915683cf" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-22 07:26:32 (8764): 
Command: VBoxManage -q bandwidthctl "boinc_d053f7ca915683cf" remove "boinc_d053f7ca915683cf_net" 
Exit Code: 0
Output:

2025-02-22 07:26:32 (8764): 
Command: VBoxManage -q unregistervm "boinc_d053f7ca915683cf" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

07:26:37 (8764): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN