Name | 2wiLDm17r56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmIBtKDm3HM9um_1 |
Workunit | 230503714 |
Created | 22 Feb 2025, 7:22:27 UTC |
Sent | 22 Feb 2025, 12:58:52 UTC |
Report deadline | 2 Mar 2025, 12:58:52 UTC |
Received | 22 Feb 2025, 13:01:15 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10870209 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 8.00 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.80 MB |
Peak swap size | 2.04 MB |
Peak disk usage | 330.20 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-22 07:59:34 (12548): Detected: vboxwrapper 26206 2025-02-22 07:59:34 (12548): Detected: BOINC client v8.0.4 2025-02-22 07:59:35 (12548): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-22 07:59:35 (12548): Successfully copied 'init_data.xml' to the shared directory. 2025-02-22 07:59:35 (12548): Create VM. (boinc_8922ea7619d4277d, slot#0) 2025-02-22 07:59:36 (12548): Setting Memory Size for VM. (4800MB) 2025-02-22 07:59:36 (12548): Setting CPU Count for VM. (8) 2025-02-22 07:59:37 (12548): Setting Chipset Options for VM. 2025-02-22 07:59:37 (12548): Setting Graphics Controller Options for VM. 2025-02-22 07:59:37 (12548): Setting Boot Options for VM. 2025-02-22 07:59:37 (12548): Setting Network Configuration for NAT. 2025-02-22 07:59:38 (12548): Enabling VM Network Access. 2025-02-22 07:59:38 (12548): Disabling USB Support for VM. 2025-02-22 07:59:38 (12548): Disabling COM Port Support for VM. 2025-02-22 07:59:38 (12548): Disabling LPT Port Support for VM. 2025-02-22 07:59:39 (12548): Disabling Audio Support for VM. 2025-02-22 07:59:39 (12548): Disabling Clipboard Support for VM. 2025-02-22 07:59:39 (12548): Disabling Drag and Drop Support for VM. 2025-02-22 07:59:39 (12548): Adding storage controller(s) to VM. 2025-02-22 07:59:40 (12548): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-22 07:59:43 (12548): Adding VirtualBox Guest Additions to VM. 2025-02-22 07:59:43 (12548): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-22 07:59:43 (12548): forwarding host port 50145 to guest port 80 2025-02-22 07:59:43 (12548): Enabling remote desktop for VM. 2025-02-22 07:59:44 (12548): Required extension pack not installed, remote desktop not enabled. 2025-02-22 07:59:44 (12548): Enabling shared directory for VM. 2025-02-22 07:59:44 (12548): Starting VM using VBoxManage interface. (boinc_8922ea7619d4277d, slot#0) 2025-02-22 07:59:45 (12548): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_8922ea7619d4277d" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_8922ea7619d4277d' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_8922ea7619d4277d" to power on... 2025-02-22 07:59:45 (12548): VM failed to start. 2025-02-22 07:59:45 (12548): Could not start 2025-02-22 07:59:45 (12548): ERROR: VM failed to start 2025-02-22 07:59:45 (12548): Powering off VM. 2025-02-22 07:59:45 (12548): Deregistering VM. (boinc_8922ea7619d4277d, slot#0) 2025-02-22 07:59:45 (12548): Removing network bandwidth throttle group from VM. 2025-02-22 07:59:45 (12548): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.965432 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.965716 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.970310 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:07.971736 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:07.979775 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:08.236085 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:08.241599 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:08.491911 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.493969 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:08.498710 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:08.498984 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.502241 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:08.506266 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:08.506910 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:08.514453 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:08.763978 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.766038 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.766277 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.768787 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:08.769290 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.771672 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:08.772258 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:08.776351 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:09.034195 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:09.039029 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:09.317790 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:09.323797 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:09.850594 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:09.856734 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:10.105798 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.114246 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.114357 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.124612 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.404642 Launched VM: 3853130064 pid: 7240 (0x1c48) frontend: headless name: boinc_8922ea7619d4277d 00:00:10.830868 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_8922ea7619d4277d' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.832232 Watcher Reaper: Pid 7240 (0x1c48) exited normally: 1 (0x1) 00:00:10.926184 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.005804 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" with version "1.19-windows" 00:00:11.012041 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox" 00:00:11.281842 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.286286 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:11.286459 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.291644 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:11.293223 DeleteVM Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.295858 DeleteVM Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:16.316411 main VirtualBox: object deletion starts 00:00:16.318047 main HostDnsMonitor: shutting down ... 00:00:16.318170 main HostDnsMonitor: shut down 00:00:16.322396 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.322768 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-22 07:59:36 (12548): Command: VBoxManage -q createvm --name "boinc_8922ea7619d4277d" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_8922ea7619d4277d' is created and registered. UUID: 0a0ec7b8-3fee-487e-a291-058145676670 Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\boinc_8922ea7619d4277d.vbox' 2025-02-22 07:59:36 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --description "2wiLDm17r56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmIBtKDm3HM9um_1" Exit Code: 0 Output: 2025-02-22 07:59:36 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --memory 4800 Exit Code: 0 Output: 2025-02-22 07:59:37 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --cpus 8 Exit Code: 0 Output: 2025-02-22 07:59:37 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-22 07:59:37 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-22 07:59:37 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-22 07:59:38 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-22 07:59:38 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --cableconnected1 on Exit Code: 0 Output: 2025-02-22 07:59:38 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --usb off Exit Code: 0 Output: 2025-02-22 07:59:38 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-22 07:59:39 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-22 07:59:39 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-22 07:59:39 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --clipboard disabled Exit Code: 0 Output: 2025-02-22 07:59:39 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --draganddrop disabled Exit Code: 0 Output: 2025-02-22 07:59:40 (12548): Command: VBoxManage -q storagectl "boinc_8922ea7619d4277d" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-22 07:59:40 (12548): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 07:59:40 (12548): Command: VBoxManage -q storageattach "boinc_8922ea7619d4277d" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-22 07:59:41 (12548): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 07:59:42 (12548): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 07:59:42 (12548): Command: VBoxManage -q storageattach "boinc_8922ea7619d4277d" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 07:59:42 (12548): Command: VBoxManage -q storageattach "boinc_8922ea7619d4277d" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-22 07:59:43 (12548): Command: VBoxManage -q storageattach "boinc_8922ea7619d4277d" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 07:59:43 (12548): Command: VBoxManage -q storageattach "boinc_8922ea7619d4277d" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-22 07:59:43 (12548): Command: VBoxManage -q bandwidthctl "boinc_8922ea7619d4277d" add "boinc_8922ea7619d4277d_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-22 07:59:43 (12548): Command: VBoxManage -q modifyvm "boinc_8922ea7619d4277d" --natpf1 ",tcp,127.0.0.1,50145,,80" Exit Code: 0 Output: 2025-02-22 07:59:44 (12548): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-22 07:59:44 (12548): Command: VBoxManage -q sharedfolder add "boinc_8922ea7619d4277d" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-22 07:59:45 (12548): Command: VBoxManage -q startvm "boinc_8922ea7619d4277d" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_8922ea7619d4277d' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_8922ea7619d4277d\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_8922ea7619d4277d" to power on... 2025-02-22 07:59:45 (12548): Command: VBoxManage -q snapshot "boinc_8922ea7619d4277d" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-22 07:59:45 (12548): Command: VBoxManage -q bandwidthctl "boinc_8922ea7619d4277d" remove "boinc_8922ea7619d4277d_net" Exit Code: 0 Output: 2025-02-22 07:59:45 (12548): Command: VBoxManage -q unregistervm "boinc_8922ea7619d4277d" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 07:59:51 (12548): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN