Name | f6ZNDmu1t56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDm0JtKDmAOVQRm_0 |
Workunit | 230504960 |
Created | 22 Feb 2025, 2:02:55 UTC |
Sent | 22 Feb 2025, 7:40:59 UTC |
Report deadline | 2 Mar 2025, 7:40:59 UTC |
Received | 22 Feb 2025, 7:43:37 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10870209 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 8.00 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.80 MB |
Peak swap size | 2.03 MB |
Peak disk usage | 329.41 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-22 02:41:37 (10592): Detected: vboxwrapper 26206 2025-02-22 02:41:37 (10592): Detected: BOINC client v8.0.4 2025-02-22 02:41:38 (10592): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-22 02:41:39 (10592): Successfully copied 'init_data.xml' to the shared directory. 2025-02-22 02:41:39 (10592): Create VM. (boinc_e82d5fcdef8da924, slot#0) 2025-02-22 02:41:40 (10592): Setting Memory Size for VM. (4800MB) 2025-02-22 02:41:40 (10592): Setting CPU Count for VM. (8) 2025-02-22 02:41:40 (10592): Setting Chipset Options for VM. 2025-02-22 02:41:41 (10592): Setting Graphics Controller Options for VM. 2025-02-22 02:41:41 (10592): Setting Boot Options for VM. 2025-02-22 02:41:41 (10592): Setting Network Configuration for NAT. 2025-02-22 02:41:41 (10592): Enabling VM Network Access. 2025-02-22 02:41:42 (10592): Disabling USB Support for VM. 2025-02-22 02:41:42 (10592): Disabling COM Port Support for VM. 2025-02-22 02:41:42 (10592): Disabling LPT Port Support for VM. 2025-02-22 02:41:42 (10592): Disabling Audio Support for VM. 2025-02-22 02:41:43 (10592): Disabling Clipboard Support for VM. 2025-02-22 02:41:43 (10592): Disabling Drag and Drop Support for VM. 2025-02-22 02:41:43 (10592): Adding storage controller(s) to VM. 2025-02-22 02:41:44 (10592): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-22 02:41:46 (10592): Adding VirtualBox Guest Additions to VM. 2025-02-22 02:41:47 (10592): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-22 02:41:47 (10592): forwarding host port 51823 to guest port 80 2025-02-22 02:41:47 (10592): Enabling remote desktop for VM. 2025-02-22 02:41:48 (10592): Required extension pack not installed, remote desktop not enabled. 2025-02-22 02:41:48 (10592): Enabling shared directory for VM. 2025-02-22 02:41:48 (10592): Starting VM using VBoxManage interface. (boinc_e82d5fcdef8da924, slot#0) 2025-02-22 02:41:49 (10592): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_e82d5fcdef8da924" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_e82d5fcdef8da924' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_e82d5fcdef8da924" to power on... 2025-02-22 02:41:49 (10592): VM failed to start. 2025-02-22 02:41:49 (10592): Could not start 2025-02-22 02:41:49 (10592): ERROR: VM failed to start 2025-02-22 02:41:49 (10592): Powering off VM. 2025-02-22 02:41:49 (10592): Deregistering VM. (boinc_e82d5fcdef8da924, slot#0) 2025-02-22 02:41:49 (10592): Removing network bandwidth throttle group from VM. 2025-02-22 02:41:49 (10592): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.975910 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.976464 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.981162 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:07.982306 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:07.987277 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:08.262526 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:08.268760 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:08.521475 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.522321 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:08.526400 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:08.526645 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.529124 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:08.532229 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:08.532831 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:08.535734 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:08.792331 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.796630 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.797095 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.800942 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:08.801306 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.803596 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:08.804151 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:08.807722 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:09.047859 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:09.053094 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:09.332801 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:09.337620 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:09.861286 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:09.867972 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:10.116965 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.133901 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.134030 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.145209 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.416058 Launched VM: 3185988736 pid: 2888 (0xb48) frontend: headless name: boinc_e82d5fcdef8da924 00:00:10.872948 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_e82d5fcdef8da924' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.874424 Watcher Reaper: Pid 2888 (0xb48) exited normally: 1 (0x1) 00:00:10.987356 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.074482 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" with version "1.19-windows" 00:00:11.081596 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox" 00:00:11.353291 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.355922 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:11.356008 Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.358073 Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:11.359303 DeleteVM Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.362924 DeleteVM Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" 00:00:16.384830 main VirtualBox: object deletion starts 00:00:16.389350 main HostDnsMonitor: shutting down ... 00:00:16.389539 main HostDnsMonitor: shut down 00:00:16.394749 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.395403 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-22 02:41:39 (10592): Command: VBoxManage -q createvm --name "boinc_e82d5fcdef8da924" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_e82d5fcdef8da924' is created and registered. UUID: 949923ca-691b-4c98-9e1d-1832853be195 Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\boinc_e82d5fcdef8da924.vbox' 2025-02-22 02:41:40 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --description "f6ZNDmu1t56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDm0JtKDmAOVQRm_0" Exit Code: 0 Output: 2025-02-22 02:41:40 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --memory 4800 Exit Code: 0 Output: 2025-02-22 02:41:40 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --cpus 8 Exit Code: 0 Output: 2025-02-22 02:41:41 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-22 02:41:41 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-22 02:41:41 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-22 02:41:41 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-22 02:41:42 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --cableconnected1 on Exit Code: 0 Output: 2025-02-22 02:41:42 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --usb off Exit Code: 0 Output: 2025-02-22 02:41:42 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-22 02:41:42 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-22 02:41:43 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-22 02:41:43 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --clipboard disabled Exit Code: 0 Output: 2025-02-22 02:41:43 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --draganddrop disabled Exit Code: 0 Output: 2025-02-22 02:41:44 (10592): Command: VBoxManage -q storagectl "boinc_e82d5fcdef8da924" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-22 02:41:44 (10592): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 02:41:44 (10592): Command: VBoxManage -q storageattach "boinc_e82d5fcdef8da924" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-22 02:41:44 (10592): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 02:41:46 (10592): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 02:41:46 (10592): Command: VBoxManage -q storageattach "boinc_e82d5fcdef8da924" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 02:41:46 (10592): Command: VBoxManage -q storageattach "boinc_e82d5fcdef8da924" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-22 02:41:46 (10592): Command: VBoxManage -q storageattach "boinc_e82d5fcdef8da924" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 02:41:47 (10592): Command: VBoxManage -q storageattach "boinc_e82d5fcdef8da924" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-22 02:41:47 (10592): Command: VBoxManage -q bandwidthctl "boinc_e82d5fcdef8da924" add "boinc_e82d5fcdef8da924_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-22 02:41:47 (10592): Command: VBoxManage -q modifyvm "boinc_e82d5fcdef8da924" --natpf1 ",tcp,127.0.0.1,51823,,80" Exit Code: 0 Output: 2025-02-22 02:41:48 (10592): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-22 02:41:48 (10592): Command: VBoxManage -q sharedfolder add "boinc_e82d5fcdef8da924" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-22 02:41:49 (10592): Command: VBoxManage -q startvm "boinc_e82d5fcdef8da924" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_e82d5fcdef8da924' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_e82d5fcdef8da924\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_e82d5fcdef8da924" to power on... 2025-02-22 02:41:49 (10592): Command: VBoxManage -q snapshot "boinc_e82d5fcdef8da924" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-22 02:41:49 (10592): Command: VBoxManage -q bandwidthctl "boinc_e82d5fcdef8da924" remove "boinc_e82d5fcdef8da924_net" Exit Code: 0 Output: 2025-02-22 02:41:49 (10592): Command: VBoxManage -q unregistervm "boinc_e82d5fcdef8da924" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 02:41:54 (10592): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN