Name iOaLDmc2r56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmxAtKDm00geNn_0
Workunit 230503670
Created 21 Feb 2025, 23:55:23 UTC
Sent 22 Feb 2025, 5:23:04 UTC
Report deadline 2 Mar 2025, 5:23:04 UTC
Received 22 Feb 2025, 5:25:37 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10870209
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 8.00 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 7.77 MB
Peak swap size 2.04 MB
Peak disk usage 325.82 MB

Stderr output

<core_client_version>8.0.4</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-22 00:23:40 (4832): Detected: vboxwrapper 26206
2025-02-22 00:23:40 (4832): Detected: BOINC client v8.0.4
2025-02-22 00:23:41 (4832): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-22 00:23:42 (4832): Successfully copied 'init_data.xml' to the shared directory.
2025-02-22 00:23:42 (4832): Create VM. (boinc_e4f489b9e4e4a96e, slot#1)
2025-02-22 00:23:43 (4832): Setting Memory Size for VM. (4800MB)
2025-02-22 00:23:43 (4832): Setting CPU Count for VM. (8)
2025-02-22 00:23:43 (4832): Setting Chipset Options for VM.
2025-02-22 00:23:44 (4832): Setting Graphics Controller Options for VM.
2025-02-22 00:23:44 (4832): Setting Boot Options for VM.
2025-02-22 00:23:44 (4832): Setting Network Configuration for NAT.
2025-02-22 00:23:44 (4832): Enabling VM Network Access.
2025-02-22 00:23:45 (4832): Disabling USB Support for VM.
2025-02-22 00:23:45 (4832): Disabling COM Port Support for VM.
2025-02-22 00:23:45 (4832): Disabling LPT Port Support for VM.
2025-02-22 00:23:45 (4832): Disabling Audio Support for VM.
2025-02-22 00:23:46 (4832): Disabling Clipboard Support for VM.
2025-02-22 00:23:46 (4832): Disabling Drag and Drop Support for VM.
2025-02-22 00:23:46 (4832): Adding storage controller(s) to VM.
2025-02-22 00:23:46 (4832): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-22 00:23:49 (4832): Adding VirtualBox Guest Additions to VM.
2025-02-22 00:23:50 (4832): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-22 00:23:50 (4832): forwarding host port 50920 to guest port 80
2025-02-22 00:23:50 (4832): Enabling remote desktop for VM.
2025-02-22 00:23:50 (4832): Required extension pack not installed, remote desktop not enabled.
2025-02-22 00:23:50 (4832): Enabling shared directory for VM.
2025-02-22 00:23:51 (4832): Starting VM using VBoxManage interface. (boinc_e4f489b9e4e4a96e, slot#1)
2025-02-22 00:23:52 (4832): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_e4f489b9e4e4a96e" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_e4f489b9e4e4a96e' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_e4f489b9e4e4a96e" to power on...

2025-02-22 00:23:52 (4832): VM failed to start.
2025-02-22 00:23:52 (4832): Could not start 
2025-02-22 00:23:52 (4832): ERROR: VM failed to start
2025-02-22 00:23:52 (4832): Powering off VM.
2025-02-22 00:23:52 (4832): Deregistering VM. (boinc_e4f489b9e4e4a96e, slot#1)
2025-02-22 00:23:52 (4832): Removing network bandwidth throttle group from VM.
2025-02-22 00:23:52 (4832): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.954305          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.954621          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.958222          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:07.959029          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:07.963921          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:08.221434          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:08.225278          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:08.460148          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.460843          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:08.464518          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:08.464807          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.467233          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:08.471603          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:08.472315          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:08.476046          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:08.740379          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.743063          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.743251          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.745458          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:08.745810          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.749092          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:08.749579          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:08.753496          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:09.012668          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:09.016372          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:09.273188          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:09.276855          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:09.806152          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:09.809913          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:10.103032          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:10.109411          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.109506          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.117792          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.348845          Launched VM: 2710581824 pid: 1380 (0x564) frontend: headless name: boinc_e4f489b9e4e4a96e
00:00:10.790155 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_e4f489b9e4e4a96e' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.790855 Watcher  Reaper: Pid 1380 (0x564) exited normally: 1 (0x1)
00:00:10.892153          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.964294          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox" with version "1.19-windows"
00:00:10.968854          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox"
00:00:11.240987          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.244258          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:11.244368          Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.247295          Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:11.249038 DeleteVM Saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.253584 DeleteVM Finished saving settings file "C:\Users\DellEMCPowerEdgeR740\.VirtualBox\VirtualBox.xml"
00:00:16.271614 main     VirtualBox: object deletion starts
00:00:16.276103 main     HostDnsMonitor: shutting down ...
00:00:16.276292 main     HostDnsMonitor: shut down
00:00:16.280993 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.281446 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

age -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-22 00:23:42 (4832): 
Command: VBoxManage -q createvm --name "boinc_e4f489b9e4e4a96e" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_e4f489b9e4e4a96e' is created and registered.
UUID: 5ca7983d-ba9f-4d90-b982-abf12fb0e3a1
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\boinc_e4f489b9e4e4a96e.vbox'

2025-02-22 00:23:43 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --description "iOaLDmc2r56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmxAtKDm00geNn_0" 
Exit Code: 0
Output:

2025-02-22 00:23:43 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --memory 4800 
Exit Code: 0
Output:

2025-02-22 00:23:43 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --cpus 8 
Exit Code: 0
Output:

2025-02-22 00:23:44 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-22 00:23:44 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-22 00:23:44 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-22 00:23:44 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-22 00:23:45 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-22 00:23:45 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --usb off 
Exit Code: 0
Output:

2025-02-22 00:23:45 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-22 00:23:45 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-22 00:23:46 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-22 00:23:46 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --clipboard disabled 
Exit Code: 0
Output:

2025-02-22 00:23:46 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-22 00:23:46 (4832): 
Command: VBoxManage -q storagectl "boinc_e4f489b9e4e4a96e" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-22 00:23:47 (4832): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 00:23:47 (4832): 
Command: VBoxManage -q storageattach "boinc_e4f489b9e4e4a96e" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-22 00:23:47 (4832): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 00:23:49 (4832): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-22 00:23:49 (4832): 
Command: VBoxManage -q storageattach "boinc_e4f489b9e4e4a96e" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 00:23:49 (4832): 
Command: VBoxManage -q storageattach "boinc_e4f489b9e4e4a96e" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-22 00:23:49 (4832): 
Command: VBoxManage -q storageattach "boinc_e4f489b9e4e4a96e" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-22 00:23:50 (4832): 
Command: VBoxManage -q storageattach "boinc_e4f489b9e4e4a96e" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-22 00:23:50 (4832): 
Command: VBoxManage -q bandwidthctl "boinc_e4f489b9e4e4a96e" add "boinc_e4f489b9e4e4a96e_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-22 00:23:50 (4832): 
Command: VBoxManage -q modifyvm "boinc_e4f489b9e4e4a96e" --natpf1 ",tcp,127.0.0.1,50920,,80" 
Exit Code: 0
Output:

2025-02-22 00:23:50 (4832): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-22 00:23:51 (4832): 
Command: VBoxManage -q sharedfolder add "boinc_e4f489b9e4e4a96e" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2025-02-22 00:23:52 (4832): 
Command: VBoxManage -q startvm "boinc_e4f489b9e4e4a96e" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_e4f489b9e4e4a96e' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_e4f489b9e4e4a96e\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_e4f489b9e4e4a96e" to power on...

2025-02-22 00:23:52 (4832): 
Command: VBoxManage -q snapshot "boinc_e4f489b9e4e4a96e" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-22 00:23:52 (4832): 
Command: VBoxManage -q bandwidthctl "boinc_e4f489b9e4e4a96e" remove "boinc_e4f489b9e4e4a96e_net" 
Exit Code: 0
Output:

2025-02-22 00:23:52 (4832): 
Command: VBoxManage -q unregistervm "boinc_e4f489b9e4e4a96e" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

00:23:57 (4832): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN