Name | w3JMDmkKh56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmsHsKDmoJ4hOm_2 |
Workunit | 230495213 |
Created | 21 Feb 2025, 21:50:39 UTC |
Sent | 22 Feb 2025, 3:01:57 UTC |
Report deadline | 2 Mar 2025, 3:01:57 UTC |
Received | 22 Feb 2025, 4:03:22 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10767264 |
Run time | 20 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 41.55 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 8.02 MB |
Peak swap size | 2.08 MB |
Peak disk usage | 328.53 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unzul�ssige Funktion. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-22 04:02:27 (10160): Detected: vboxwrapper 26206 2025-02-22 04:02:27 (10160): Detected: BOINC client v8.0.2 2025-02-22 04:02:28 (10160): Detected: VirtualBox VboxManage Interface (Version: 7.0.8) 2025-02-22 04:02:28 (10160): Successfully copied 'init_data.xml' to the shared directory. 2025-02-22 04:02:29 (10160): Create VM. (boinc_814c0651bde92d26, slot#32) 2025-02-22 04:02:30 (10160): Setting Memory Size for VM. (4800MB) 2025-02-22 04:02:30 (10160): Setting CPU Count for VM. (8) 2025-02-22 04:02:30 (10160): Setting Chipset Options for VM. 2025-02-22 04:02:30 (10160): Setting Graphics Controller Options for VM. 2025-02-22 04:02:31 (10160): Setting Boot Options for VM. 2025-02-22 04:02:31 (10160): Setting Network Configuration for NAT. 2025-02-22 04:02:31 (10160): Enabling VM Network Access. 2025-02-22 04:02:32 (10160): Disabling USB Support for VM. 2025-02-22 04:02:32 (10160): Disabling COM Port Support for VM. 2025-02-22 04:02:32 (10160): Disabling LPT Port Support for VM. 2025-02-22 04:02:32 (10160): Disabling Audio Support for VM. 2025-02-22 04:02:33 (10160): Disabling Clipboard Support for VM. 2025-02-22 04:02:33 (10160): Disabling Drag and Drop Support for VM. 2025-02-22 04:02:33 (10160): Adding storage controller(s) to VM. 2025-02-22 04:02:33 (10160): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-22 04:02:36 (10160): Adding VirtualBox Guest Additions to VM. 2025-02-22 04:02:37 (10160): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-22 04:02:37 (10160): forwarding host port 51004 to guest port 80 2025-02-22 04:02:37 (10160): Enabling remote desktop for VM. 2025-02-22 04:02:38 (10160): Required extension pack not installed, remote desktop not enabled. 2025-02-22 04:02:38 (10160): Enabling shared directory for VM. 2025-02-22 04:02:38 (10160): Starting VM using VBoxManage interface. (boinc_814c0651bde92d26, slot#32) 2025-02-22 04:02:39 (10160): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_814c0651bde92d26" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_814c0651bde92d26' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_814c0651bde92d26" to power on... 2025-02-22 04:02:39 (10160): VM failed to start. 2025-02-22 04:02:39 (10160): Could not start 2025-02-22 04:02:39 (10160): ERROR: VM failed to start 2025-02-22 04:02:39 (10160): Powering off VM. 2025-02-22 04:02:39 (10160): Deregistering VM. (boinc_814c0651bde92d26, slot#32) 2025-02-22 04:02:39 (10160): Removing network bandwidth throttle group from VM. 2025-02-22 04:02:39 (10160): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.557340 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.558095 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.562542 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:08.563377 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:08.567465 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:08.810442 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:08.816051 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:09.116249 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.117024 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:09.120181 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:09.120467 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.123925 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:09.126990 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:09.127662 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:09.130634 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:09.466316 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.484924 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.485141 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.488890 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:09.489352 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.493087 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:09.493916 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:09.502507 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:09.690265 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:09.693603 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:09.997883 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:10.001288 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:10.526516 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:10.529425 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:10.815566 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:10.830889 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.831006 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.842202 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.065067 Launched VM: 3000043776 pid: 21964 (0x55cc) frontend: headless name: boinc_814c0651bde92d26 00:00:11.619842 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_814c0651bde92d26' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.620379 Watcher Reaper: Pid 21964 (0x55cc) exited normally: 1 (0x1) 00:00:11.786861 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.920856 Saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" with version "1.19-windows" 00:00:11.926552 Finished saving settings file "C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox" 00:00:12.146885 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.153073 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:12.153517 Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.162652 Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:12.165573 DeleteVM Saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.182922 DeleteVM Finished saving settings file "C:\Users\Sandro\.VirtualBox\VirtualBox.xml" 00:00:17.226481 main VirtualBox: object deletion starts 00:00:17.231262 main HostDnsMonitor: shutting down ... 00:00:17.231588 main HostDnsMonitor: shut down 00:00:17.245255 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:17.246118 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: C\slots\32/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\32\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 201 of file VBoxManageDisk.cpp 2025-02-22 04:02:29 (10160): Command: VBoxManage -q createvm --name "boinc_814c0651bde92d26" --basefolder "C:\ProgramData\BOINC\slots\32" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_814c0651bde92d26' is created and registered. UUID: 3c95052b-4c19-4cd5-aacb-2881075e7980 Settings file: 'C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\boinc_814c0651bde92d26.vbox' 2025-02-22 04:02:30 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --description "w3JMDmkKh56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmsHsKDmoJ4hOm_2" Exit Code: 0 Output: 2025-02-22 04:02:30 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --memory 4800 Exit Code: 0 Output: 2025-02-22 04:02:30 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --cpus 8 Exit Code: 0 Output: 2025-02-22 04:02:30 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-22 04:02:31 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-22 04:02:31 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-22 04:02:31 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-22 04:02:32 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --cableconnected1 on Exit Code: 0 Output: 2025-02-22 04:02:32 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --usb off Exit Code: 0 Output: 2025-02-22 04:02:32 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-22 04:02:32 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-22 04:02:33 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-22 04:02:33 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --clipboard disabled Exit Code: 0 Output: 2025-02-22 04:02:33 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --draganddrop disabled Exit Code: 0 Output: 2025-02-22 04:02:33 (10160): Command: VBoxManage -q storagectl "boinc_814c0651bde92d26" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-22 04:02:34 (10160): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 04:02:34 (10160): Command: VBoxManage -q storageattach "boinc_814c0651bde92d26" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-22 04:02:34 (10160): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 04:02:36 (10160): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-22 04:02:36 (10160): Command: VBoxManage -q storageattach "boinc_814c0651bde92d26" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 04:02:36 (10160): Command: VBoxManage -q storageattach "boinc_814c0651bde92d26" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-22 04:02:36 (10160): Command: VBoxManage -q storageattach "boinc_814c0651bde92d26" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-22 04:02:37 (10160): Command: VBoxManage -q storageattach "boinc_814c0651bde92d26" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-22 04:02:37 (10160): Command: VBoxManage -q bandwidthctl "boinc_814c0651bde92d26" add "boinc_814c0651bde92d26_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-22 04:02:37 (10160): Command: VBoxManage -q modifyvm "boinc_814c0651bde92d26" --natpf1 ",tcp,127.0.0.1,51004,,80" Exit Code: 0 Output: 2025-02-22 04:02:38 (10160): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-22 04:02:38 (10160): Command: VBoxManage -q sharedfolder add "boinc_814c0651bde92d26" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\32/shared" Exit Code: 0 Output: 2025-02-22 04:02:39 (10160): Command: VBoxManage -q startvm "boinc_814c0651bde92d26" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_814c0651bde92d26' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\32\boinc_814c0651bde92d26\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_814c0651bde92d26" to power on... 2025-02-22 04:02:39 (10160): Command: VBoxManage -q snapshot "boinc_814c0651bde92d26" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-22 04:02:39 (10160): Command: VBoxManage -q bandwidthctl "boinc_814c0651bde92d26" remove "boinc_814c0651bde92d26_net" Exit Code: 0 Output: 2025-02-22 04:02:39 (10160): Command: VBoxManage -q unregistervm "boinc_814c0651bde92d26" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 04:02:45 (10160): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN