Name | cS9NDmKXT26n9Rq4apOajLDm4fhM0noT9bVoFjIUDmE0QKDma4rC1m_0 |
Workunit | 230309659 |
Created | 12 Feb 2025, 15:09:17 UTC |
Sent | 12 Feb 2025, 18:30:56 UTC |
Report deadline | 20 Feb 2025, 18:30:56 UTC |
Received | 12 Feb 2025, 19:53:47 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -1073741819 (0xC0000005) STATUS_ACCESS_VIOLATION |
Computer ID | 10772314 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 32.32 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 14.76 MB |
Peak swap size | 8.84 MB |
Peak disk usage | 329.39 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> (unknown error) (317) - exit code 3221225477 (0xc0000005)</message> <stderr_txt> 2025-02-12 19:53:16 (3644): Detected: vboxwrapper 26206 2025-02-12 19:53:16 (3644): Detected: BOINC client v7.24.1 2025-02-12 19:53:17 (3644): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-12 19:53:17 (3644): Successfully copied 'init_data.xml' to the shared directory. 2025-02-12 19:53:18 (3644): Create VM. (boinc_28d62c3bd4c78811, slot#5) 2025-02-12 19:53:18 (3644): Setting Memory Size for VM. (4600MB) 2025-02-12 19:53:19 (3644): Setting CPU Count for VM. (6) 2025-02-12 19:53:19 (3644): Setting Chipset Options for VM. 2025-02-12 19:53:19 (3644): Setting Graphics Controller Options for VM. 2025-02-12 19:53:19 (3644): Setting Boot Options for VM. 2025-02-12 19:53:20 (3644): Setting Network Configuration for NAT. 2025-02-12 19:53:20 (3644): Enabling VM Network Access. 2025-02-12 19:53:20 (3644): Disabling USB Support for VM. 2025-02-12 19:53:21 (3644): Disabling COM Port Support for VM. 2025-02-12 19:53:21 (3644): Disabling LPT Port Support for VM. 2025-02-12 19:53:21 (3644): Disabling Audio Support for VM. 2025-02-12 19:53:21 (3644): Disabling Clipboard Support for VM. 2025-02-12 19:53:22 (3644): Disabling Drag and Drop Support for VM. 2025-02-12 19:53:22 (3644): Adding storage controller(s) to VM. 2025-02-12 19:53:22 (3644): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-12 19:53:25 (3644): Adding VirtualBox Guest Additions to VM. 2025-02-12 19:53:25 (3644): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-12 19:53:25 (3644): forwarding host port 53608 to guest port 80 2025-02-12 19:53:26 (3644): Enabling remote desktop for VM. 2025-02-12 19:53:26 (3644): Required extension pack not installed, remote desktop not enabled. 2025-02-12 19:53:26 (3644): Enabling shared directory for VM. 2025-02-12 19:53:26 (3644): Starting VM using VBoxManage interface. (boinc_28d62c3bd4c78811, slot#5) 2025-02-12 19:53:27 (3644): Error in start VM for VM: -1073741819 Command: VBoxManage -q startvm "boinc_28d62c3bd4c78811" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_28d62c3bd4c78811' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_28d62c3bd4c78811" to power on... 2025-02-12 19:53:27 (3644): VM failed to start. 2025-02-12 19:53:27 (3644): Could not start 2025-02-12 19:53:27 (3644): ERROR: VM failed to start 2025-02-12 19:53:27 (3644): Powering off VM. 2025-02-12 19:53:27 (3644): Deregistering VM. (boinc_28d62c3bd4c78811, slot#5) 2025-02-12 19:53:27 (3644): Removing network bandwidth throttle group from VM. 2025-02-12 19:53:28 (3644): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.600263 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.600716 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.600954 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.603925 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:07.604320 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:07.607412 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:07.859019 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:07.862203 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:08.123558 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.124281 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:08.127902 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:08.128054 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.130140 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:08.132717 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:08.133101 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:08.136386 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:08.376019 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.380627 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.380817 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.384017 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:08.384286 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.387255 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:08.387574 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:08.390453 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:08.632178 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:08.636292 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:08.887460 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:08.890881 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:09.396846 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:09.400818 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:09.659849 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.668997 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.669136 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.680342 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.935819 Launched VM: 932538496 pid: 24032 (0x5de0) frontend: headless name: boinc_28d62c3bd4c78811 00:00:10.645958 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_28d62c3bd4c78811' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005)}, preserve=false aResultDetail=0 00:00:10.646922 Watcher Reaper: Pid 24032 (0x5de0) exited normally: -1073741819 (0xc0000005) 00:00:10.722511 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.786077 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" with version "1.19-windows" 00:00:10.789537 Finished saving settings file "C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox" 00:00:11.044519 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.048218 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:11.048329 Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.051398 Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:11.052439 DeleteVM Saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.056062 DeleteVM Finished saving settings file "C:\Users\Sjef\.VirtualBox\VirtualBox.xml" 00:00:16.068273 main VirtualBox: object deletion starts 00:00:16.068961 main HostDnsMonitor: shutting down ... 00:00:16.068999 main HostDnsMonitor: shut down 00:00:16.070465 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.071090 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: ine 3139 of file VBoxManageInfo.cpp 2025-02-12 19:53:18 (3644): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\5/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\5\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-12 19:53:18 (3644): Command: VBoxManage -q createvm --name "boinc_28d62c3bd4c78811" --basefolder "C:\ProgramData\BOINC\slots\5" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_28d62c3bd4c78811' is created and registered. UUID: c7b89422-1a8d-48a1-b195-4fbfcaccde14 Settings file: 'C:\ProgramData\BOINC\slots\5\boinc_28d62c3bd4c78811\boinc_28d62c3bd4c78811.vbox' 2025-02-12 19:53:18 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --description "cS9NDmKXT26n9Rq4apOajLDm4fhM0noT9bVoFjIUDmE0QKDma4rC1m_0" Exit Code: 0 Output: 2025-02-12 19:53:19 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --memory 4600 Exit Code: 0 Output: 2025-02-12 19:53:19 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --cpus 6 Exit Code: 0 Output: 2025-02-12 19:53:19 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-12 19:53:19 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-12 19:53:20 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-12 19:53:20 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-12 19:53:20 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --cableconnected1 on Exit Code: 0 Output: 2025-02-12 19:53:21 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --usb off Exit Code: 0 Output: 2025-02-12 19:53:21 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-12 19:53:21 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-12 19:53:21 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-12 19:53:22 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --clipboard disabled Exit Code: 0 Output: 2025-02-12 19:53:22 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --draganddrop disabled Exit Code: 0 Output: 2025-02-12 19:53:22 (3644): Command: VBoxManage -q storagectl "boinc_28d62c3bd4c78811" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-12 19:53:22 (3644): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-12 19:53:23 (3644): Command: VBoxManage -q storageattach "boinc_28d62c3bd4c78811" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-12 19:53:23 (3644): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-12 19:53:24 (3644): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-12 19:53:24 (3644): Command: VBoxManage -q storageattach "boinc_28d62c3bd4c78811" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-12 19:53:25 (3644): Command: VBoxManage -q storageattach "boinc_28d62c3bd4c78811" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-12 19:53:25 (3644): Command: VBoxManage -q storageattach "boinc_28d62c3bd4c78811" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-12 19:53:25 (3644): Command: VBoxManage -q storageattach "boinc_28d62c3bd4c78811" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-12 19:53:25 (3644): Command: VBoxManage -q bandwidthctl "boinc_28d62c3bd4c78811" add "boinc_28d62c3bd4c78811_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-12 19:53:26 (3644): Command: VBoxManage -q modifyvm "boinc_28d62c3bd4c78811" --natpf1 ",tcp,127.0.0.1,53608,,80" Exit Code: 0 Output: 2025-02-12 19:53:26 (3644): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-12 19:53:26 (3644): Command: VBoxManage -q sharedfolder add "boinc_28d62c3bd4c78811" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\5/shared" Exit Code: 0 Output: 2025-02-12 19:53:27 (3644): Command: VBoxManage -q startvm "boinc_28d62c3bd4c78811" --type headless Exit Code: -1073741819 Output: VBoxManage.exe: error: The virtual machine 'boinc_28d62c3bd4c78811' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_28d62c3bd4c78811" to power on... 2025-02-12 19:53:27 (3644): Command: VBoxManage -q snapshot "boinc_28d62c3bd4c78811" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-12 19:53:28 (3644): Command: VBoxManage -q bandwidthctl "boinc_28d62c3bd4c78811" remove "boinc_28d62c3bd4c78811_net" Exit Code: 0 Output: 2025-02-12 19:53:28 (3644): Command: VBoxManage -q unregistervm "boinc_28d62c3bd4c78811" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 19:53:33 (3644): called boinc_finish(-1073741819) </stderr_txt> ]]>
©2025 CERN