Name H5sMDmV2H16nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmtORKDmC84NNo_0
Workunit 230236596
Created 9 Feb 2025, 8:40:28 UTC
Sent 9 Feb 2025, 11:14:34 UTC
Report deadline 17 Feb 2025, 11:14:34 UTC
Received 9 Feb 2025, 12:15:40 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10848068
Run time 18 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 45.09 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 8.00 MB
Peak swap size 2.05 MB
Peak disk usage 329.59 MB

Stderr output

<core_client_version>7.24.1</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-09 05:15:17 (15020): Detected: vboxwrapper 26206
2025-02-09 05:15:17 (15020): Detected: BOINC client v7.24.1
2025-02-09 05:15:18 (15020): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-09 05:15:18 (15020): Successfully copied 'init_data.xml' to the shared directory.
2025-02-09 05:15:18 (15020): Create VM. (boinc_44ea38fec0c7cb13, slot#13)
2025-02-09 05:15:19 (15020): Setting Memory Size for VM. (4800MB)
2025-02-09 05:15:19 (15020): Setting CPU Count for VM. (8)
2025-02-09 05:15:19 (15020): Setting Chipset Options for VM.
2025-02-09 05:15:20 (15020): Setting Graphics Controller Options for VM.
2025-02-09 05:15:20 (15020): Setting Boot Options for VM.
2025-02-09 05:15:20 (15020): Setting Network Configuration for NAT.
2025-02-09 05:15:20 (15020): Enabling VM Network Access.
2025-02-09 05:15:21 (15020): Disabling USB Support for VM.
2025-02-09 05:15:21 (15020): Disabling COM Port Support for VM.
2025-02-09 05:15:21 (15020): Disabling LPT Port Support for VM.
2025-02-09 05:15:22 (15020): Disabling Audio Support for VM.
2025-02-09 05:15:22 (15020): Disabling Clipboard Support for VM.
2025-02-09 05:15:22 (15020): Disabling Drag and Drop Support for VM.
2025-02-09 05:15:22 (15020): Adding storage controller(s) to VM.
2025-02-09 05:15:23 (15020): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-09 05:15:25 (15020): Adding VirtualBox Guest Additions to VM.
2025-02-09 05:15:26 (15020): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-09 05:15:26 (15020): forwarding host port 64977 to guest port 80
2025-02-09 05:15:26 (15020): Enabling remote desktop for VM.
2025-02-09 05:15:26 (15020): Required extension pack not installed, remote desktop not enabled.
2025-02-09 05:15:26 (15020): Enabling shared directory for VM.
2025-02-09 05:15:27 (15020): Starting VM using VBoxManage interface. (boinc_44ea38fec0c7cb13, slot#13)
2025-02-09 05:15:28 (15020): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_44ea38fec0c7cb13" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_44ea38fec0c7cb13' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_44ea38fec0c7cb13" to power on...

2025-02-09 05:15:28 (15020): VM failed to start.
2025-02-09 05:15:28 (15020): Could not start 
2025-02-09 05:15:28 (15020): ERROR: VM failed to start
2025-02-09 05:15:28 (15020): Powering off VM.
2025-02-09 05:15:28 (15020): Deregistering VM. (boinc_44ea38fec0c7cb13, slot#13)
2025-02-09 05:15:28 (15020): Removing network bandwidth throttle group from VM.
2025-02-09 05:15:28 (15020): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.591615          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.591754          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.596128          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:07.596498          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:07.599637          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:07.853209          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:07.857016          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:08.118342          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.118950          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:08.122654          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:08.122944          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.125522          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:08.129279          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:08.129798          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:08.133833          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:08.391008          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.392562          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.392735          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.397151          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:08.397549          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.402133          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:08.402559          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:08.406640          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:08.655358          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:08.659561          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:08.914617          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:08.918938          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:09.461711          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:09.465842          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:09.709261          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:09.714489          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.714565          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.721463          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.978027          Launched VM: 250195104 pid: 43824 (0xab30) frontend: headless name: boinc_44ea38fec0c7cb13
00:00:10.613502 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_44ea38fec0c7cb13' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.613895 Watcher  Reaper: Pid 43824 (0xab30) exited normally: 1 (0x1)
00:00:10.669329          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.719065          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox" with version "1.19-windows"
00:00:10.723229          Finished saving settings file "C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox"
00:00:10.967526          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.971391          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:10.971504          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.975325          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:10.976183 DeleteVM Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.980303 DeleteVM Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:15.992550 main     VirtualBox: object deletion starts
00:00:15.993399 main     HostDnsMonitor: shutting down ...
00:00:15.993432 main     HostDnsMonitor: shut down
00:00:15.995530 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:15.995797 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

C\slots\13/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\13\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-09 05:15:19 (15020): 
Command: VBoxManage -q createvm --name "boinc_44ea38fec0c7cb13" --basefolder "C:\ProgramData\BOINC\slots\13" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_44ea38fec0c7cb13' is created and registered.
UUID: 3c1632a5-220c-47f9-af84-8a637826ed3f
Settings file: 'C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\boinc_44ea38fec0c7cb13.vbox'

2025-02-09 05:15:19 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --description "H5sMDmV2H16nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmtORKDmC84NNo_0" 
Exit Code: 0
Output:

2025-02-09 05:15:19 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --memory 4800 
Exit Code: 0
Output:

2025-02-09 05:15:19 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --cpus 8 
Exit Code: 0
Output:

2025-02-09 05:15:20 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-09 05:15:20 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-09 05:15:20 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-09 05:15:20 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-09 05:15:21 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-09 05:15:21 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --usb off 
Exit Code: 0
Output:

2025-02-09 05:15:21 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-09 05:15:22 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-09 05:15:22 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-09 05:15:22 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --clipboard disabled 
Exit Code: 0
Output:

2025-02-09 05:15:22 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-09 05:15:23 (15020): 
Command: VBoxManage -q storagectl "boinc_44ea38fec0c7cb13" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-09 05:15:23 (15020): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-09 05:15:23 (15020): 
Command: VBoxManage -q storageattach "boinc_44ea38fec0c7cb13" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-09 05:15:23 (15020): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-09 05:15:25 (15020): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-09 05:15:25 (15020): 
Command: VBoxManage -q storageattach "boinc_44ea38fec0c7cb13" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-09 05:15:25 (15020): 
Command: VBoxManage -q storageattach "boinc_44ea38fec0c7cb13" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-09 05:15:25 (15020): 
Command: VBoxManage -q storageattach "boinc_44ea38fec0c7cb13" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-09 05:15:26 (15020): 
Command: VBoxManage -q storageattach "boinc_44ea38fec0c7cb13" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-09 05:15:26 (15020): 
Command: VBoxManage -q bandwidthctl "boinc_44ea38fec0c7cb13" add "boinc_44ea38fec0c7cb13_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-09 05:15:26 (15020): 
Command: VBoxManage -q modifyvm "boinc_44ea38fec0c7cb13" --natpf1 ",tcp,127.0.0.1,64977,,80" 
Exit Code: 0
Output:

2025-02-09 05:15:26 (15020): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-09 05:15:27 (15020): 
Command: VBoxManage -q sharedfolder add "boinc_44ea38fec0c7cb13" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\13/shared"
Exit Code: 0
Output:

2025-02-09 05:15:28 (15020): 
Command: VBoxManage -q startvm "boinc_44ea38fec0c7cb13" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_44ea38fec0c7cb13' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\13\boinc_44ea38fec0c7cb13\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_44ea38fec0c7cb13" to power on...

2025-02-09 05:15:28 (15020): 
Command: VBoxManage -q snapshot "boinc_44ea38fec0c7cb13" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-09 05:15:28 (15020): 
Command: VBoxManage -q bandwidthctl "boinc_44ea38fec0c7cb13" remove "boinc_44ea38fec0c7cb13_net" 
Exit Code: 0
Output:

2025-02-09 05:15:28 (15020): 
Command: VBoxManage -q unregistervm "boinc_44ea38fec0c7cb13" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

05:15:33 (15020): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN