Name 4SXLDmMpE16nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmhtQKDmN8IU5m_0
Workunit 230232728
Created 9 Feb 2025, 5:14:40 UTC
Sent 9 Feb 2025, 7:54:02 UTC
Report deadline 17 Feb 2025, 7:54:02 UTC
Received 9 Feb 2025, 8:18:25 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10848068
Run time 17 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 45.09 GFLOPS
Application version ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas)
windows_x86_64
Peak working set size 11.16 MB
Peak swap size 2.18 MB
Peak disk usage 326.44 MB

Stderr output

<core_client_version>7.24.1</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-02-09 01:54:41 (37868): Detected: vboxwrapper 26206
2025-02-09 01:54:41 (37868): Detected: BOINC client v7.24.1
2025-02-09 01:54:42 (37868): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-02-09 01:54:42 (37868): Successfully copied 'init_data.xml' to the shared directory.
2025-02-09 01:54:43 (37868): Create VM. (boinc_5b28c4be5aa2d018, slot#18)
2025-02-09 01:54:43 (37868): Setting Memory Size for VM. (4800MB)
2025-02-09 01:54:44 (37868): Setting CPU Count for VM. (8)
2025-02-09 01:54:44 (37868): Setting Chipset Options for VM.
2025-02-09 01:54:44 (37868): Setting Graphics Controller Options for VM.
2025-02-09 01:54:44 (37868): Setting Boot Options for VM.
2025-02-09 01:54:45 (37868): Setting Network Configuration for NAT.
2025-02-09 01:54:45 (37868): Enabling VM Network Access.
2025-02-09 01:54:45 (37868): Disabling USB Support for VM.
2025-02-09 01:54:45 (37868): Disabling COM Port Support for VM.
2025-02-09 01:54:46 (37868): Disabling LPT Port Support for VM.
2025-02-09 01:54:46 (37868): Disabling Audio Support for VM.
2025-02-09 01:54:46 (37868): Disabling Clipboard Support for VM.
2025-02-09 01:54:47 (37868): Disabling Drag and Drop Support for VM.
2025-02-09 01:54:47 (37868): Adding storage controller(s) to VM.
2025-02-09 01:54:47 (37868): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi)
2025-02-09 01:54:50 (37868): Adding VirtualBox Guest Additions to VM.
2025-02-09 01:54:50 (37868): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-02-09 01:54:50 (37868): forwarding host port 62861 to guest port 80
2025-02-09 01:54:51 (37868): Enabling remote desktop for VM.
2025-02-09 01:54:51 (37868): Required extension pack not installed, remote desktop not enabled.
2025-02-09 01:54:51 (37868): Enabling shared directory for VM.
2025-02-09 01:54:52 (37868): Starting VM using VBoxManage interface. (boinc_5b28c4be5aa2d018, slot#18)
2025-02-09 01:54:52 (37868): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_5b28c4be5aa2d018" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_5b28c4be5aa2d018' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_5b28c4be5aa2d018" to power on...

2025-02-09 01:54:52 (37868): VM failed to start.
2025-02-09 01:54:52 (37868): Could not start 
2025-02-09 01:54:52 (37868): ERROR: VM failed to start
2025-02-09 01:54:52 (37868): Powering off VM.
2025-02-09 01:54:52 (37868): Deregistering VM. (boinc_5b28c4be5aa2d018, slot#18)
2025-02-09 01:54:52 (37868): Removing network bandwidth throttle group from VM.
2025-02-09 01:54:53 (37868): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.615928          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.616109          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.619984          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:07.620473          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:07.624079          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:07.881607          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:07.886566          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:08.141923          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.142539          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:08.147113          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:08.147322          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.149244          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:08.153121          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:08.153645          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:08.157156          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:08.407592          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.409147          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.409338          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.413592          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:08.413993          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.417885          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:08.418357          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:08.421857          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:08.701042          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:08.704780          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:08.939599          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:08.943477          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:09.468934          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:09.473792          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:09.725786          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:09.730894          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.730968          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.736799          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.996604          Launched VM: 2140502320 pid: 43060 (0xa834) frontend: headless name: boinc_5b28c4be5aa2d018
00:00:10.649920 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_5b28c4be5aa2d018' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.650351 Watcher  Reaper: Pid 43060 (0xa834) exited normally: 1 (0x1)
00:00:10.701273          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.748569          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox" with version "1.19-windows"
00:00:10.753263          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox"
00:00:11.013208          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.017241          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:11.017388          Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.020842          Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:11.021659 DeleteVM Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.025816 DeleteVM Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml"
00:00:16.036028 main     VirtualBox: object deletion starts
00:00:16.036568 main     HostDnsMonitor: shutting down ...
00:00:16.036596 main     HostDnsMonitor: shut down
00:00:16.038298 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.038575 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

C\slots\18/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\18\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp

2025-02-09 01:54:43 (37868): 
Command: VBoxManage -q createvm --name "boinc_5b28c4be5aa2d018" --basefolder "C:\ProgramData\BOINC\slots\18" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_5b28c4be5aa2d018' is created and registered.
UUID: 917e4ffb-8680-495b-8da9-3fd587d030ee
Settings file: 'C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\boinc_5b28c4be5aa2d018.vbox'

2025-02-09 01:54:43 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --description "4SXLDmMpE16nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmhtQKDmN8IU5m_0" 
Exit Code: 0
Output:

2025-02-09 01:54:44 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --memory 4800 
Exit Code: 0
Output:

2025-02-09 01:54:44 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --cpus 8 
Exit Code: 0
Output:

2025-02-09 01:54:44 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-02-09 01:54:44 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-02-09 01:54:45 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-02-09 01:54:45 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-02-09 01:54:45 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --cableconnected1 on 
Exit Code: 0
Output:

2025-02-09 01:54:45 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --usb off 
Exit Code: 0
Output:

2025-02-09 01:54:46 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-02-09 01:54:46 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-02-09 01:54:46 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2025-02-09 01:54:47 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --clipboard disabled 
Exit Code: 0
Output:

2025-02-09 01:54:47 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --draganddrop disabled 
Exit Code: 0
Output:

2025-02-09 01:54:47 (37868): 
Command: VBoxManage -q storagectl "boinc_5b28c4be5aa2d018" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-02-09 01:54:47 (37868): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-09 01:54:48 (37868): 
Command: VBoxManage -q storageattach "boinc_5b28c4be5aa2d018" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-02-09 01:54:48 (37868): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-09 01:54:49 (37868): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:
UUID:           ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   4204 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-02-09 01:54:49 (37868): 
Command: VBoxManage -q storageattach "boinc_5b28c4be5aa2d018" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-09 01:54:50 (37868): 
Command: VBoxManage -q storageattach "boinc_5b28c4be5aa2d018" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-02-09 01:54:50 (37868): 
Command: VBoxManage -q storageattach "boinc_5b28c4be5aa2d018" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" 
Exit Code: 0
Output:

2025-02-09 01:54:50 (37868): 
Command: VBoxManage -q storageattach "boinc_5b28c4be5aa2d018" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-02-09 01:54:50 (37868): 
Command: VBoxManage -q bandwidthctl "boinc_5b28c4be5aa2d018" add "boinc_5b28c4be5aa2d018_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-02-09 01:54:51 (37868): 
Command: VBoxManage -q modifyvm "boinc_5b28c4be5aa2d018" --natpf1 ",tcp,127.0.0.1,62861,,80" 
Exit Code: 0
Output:

2025-02-09 01:54:51 (37868): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-02-09 01:54:51 (37868): 
Command: VBoxManage -q sharedfolder add "boinc_5b28c4be5aa2d018" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\18/shared"
Exit Code: 0
Output:

2025-02-09 01:54:52 (37868): 
Command: VBoxManage -q startvm "boinc_5b28c4be5aa2d018" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_5b28c4be5aa2d018' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\18\boinc_5b28c4be5aa2d018\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_5b28c4be5aa2d018" to power on...

2025-02-09 01:54:52 (37868): 
Command: VBoxManage -q snapshot "boinc_5b28c4be5aa2d018" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-02-09 01:54:53 (37868): 
Command: VBoxManage -q bandwidthctl "boinc_5b28c4be5aa2d018" remove "boinc_5b28c4be5aa2d018_net" 
Exit Code: 0
Output:

2025-02-09 01:54:53 (37868): 
Command: VBoxManage -q unregistervm "boinc_5b28c4be5aa2d018" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

01:54:58 (37868): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN