Name | CteNDm4eC16nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmfYQKDm1PxXpn_0 |
Workunit | 230230361 |
Created | 9 Feb 2025, 2:55:58 UTC |
Sent | 9 Feb 2025, 5:36:15 UTC |
Report deadline | 17 Feb 2025, 5:36:15 UTC |
Received | 9 Feb 2025, 6:37:42 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10848068 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 45.09 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.97 MB |
Peak swap size | 2.04 MB |
Peak disk usage | 331.60 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-08 23:36:37 (14884): Detected: vboxwrapper 26206 2025-02-08 23:36:37 (14884): Detected: BOINC client v7.24.1 2025-02-08 23:36:38 (14884): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-08 23:36:38 (14884): Successfully copied 'init_data.xml' to the shared directory. 2025-02-08 23:36:39 (14884): Create VM. (boinc_0c84f566cbe4b6c6, slot#17) 2025-02-08 23:36:39 (14884): Setting Memory Size for VM. (4800MB) 2025-02-08 23:36:39 (14884): Setting CPU Count for VM. (8) 2025-02-08 23:36:40 (14884): Setting Chipset Options for VM. 2025-02-08 23:36:40 (14884): Setting Graphics Controller Options for VM. 2025-02-08 23:36:40 (14884): Setting Boot Options for VM. 2025-02-08 23:36:41 (14884): Setting Network Configuration for NAT. 2025-02-08 23:36:41 (14884): Enabling VM Network Access. 2025-02-08 23:36:41 (14884): Disabling USB Support for VM. 2025-02-08 23:36:41 (14884): Disabling COM Port Support for VM. 2025-02-08 23:36:42 (14884): Disabling LPT Port Support for VM. 2025-02-08 23:36:42 (14884): Disabling Audio Support for VM. 2025-02-08 23:36:42 (14884): Disabling Clipboard Support for VM. 2025-02-08 23:36:42 (14884): Disabling Drag and Drop Support for VM. 2025-02-08 23:36:43 (14884): Adding storage controller(s) to VM. 2025-02-08 23:36:43 (14884): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-08 23:36:46 (14884): Adding VirtualBox Guest Additions to VM. 2025-02-08 23:36:46 (14884): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-08 23:36:46 (14884): forwarding host port 50201 to guest port 80 2025-02-08 23:36:47 (14884): Enabling remote desktop for VM. 2025-02-08 23:36:47 (14884): Required extension pack not installed, remote desktop not enabled. 2025-02-08 23:36:47 (14884): Enabling shared directory for VM. 2025-02-08 23:36:47 (14884): Starting VM using VBoxManage interface. (boinc_0c84f566cbe4b6c6, slot#17) 2025-02-08 23:36:48 (14884): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_0c84f566cbe4b6c6" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_0c84f566cbe4b6c6' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_0c84f566cbe4b6c6" to power on... 2025-02-08 23:36:48 (14884): VM failed to start. 2025-02-08 23:36:48 (14884): Could not start 2025-02-08 23:36:48 (14884): ERROR: VM failed to start 2025-02-08 23:36:48 (14884): Powering off VM. 2025-02-08 23:36:48 (14884): Deregistering VM. (boinc_0c84f566cbe4b6c6, slot#17) 2025-02-08 23:36:48 (14884): Removing network bandwidth throttle group from VM. 2025-02-08 23:36:48 (14884): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.576358 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.576522 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.580533 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:07.580918 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:07.584212 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:07.843616 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:07.847541 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:08.105286 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.105823 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:08.110249 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:08.110431 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.112571 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:08.116304 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:08.116788 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:08.120248 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:08.372933 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.374422 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.374636 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.379268 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:08.379612 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.383437 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:08.383856 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:08.387465 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:08.640475 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:08.644951 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:08.907670 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:08.911699 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:09.430636 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:09.435152 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:09.692296 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.698246 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.698334 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.705411 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.961791 Launched VM: 375739520 pid: 42992 (0xa7f0) frontend: headless name: boinc_0c84f566cbe4b6c6 00:00:10.598442 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_0c84f566cbe4b6c6' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.598864 Watcher Reaper: Pid 42992 (0xa7f0) exited normally: 1 (0x1) 00:00:10.654653 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.698086 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" with version "1.19-windows" 00:00:10.701888 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox" 00:00:10.967751 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.971935 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:10.972102 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.975750 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:10.976505 DeleteVM Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.980049 DeleteVM Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:15.996588 main VirtualBox: object deletion starts 00:00:15.997131 main HostDnsMonitor: shutting down ... 00:00:15.997159 main HostDnsMonitor: shut down 00:00:15.998672 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.998905 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: C\slots\17/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\17\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-08 23:36:39 (14884): Command: VBoxManage -q createvm --name "boinc_0c84f566cbe4b6c6" --basefolder "C:\ProgramData\BOINC\slots\17" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_0c84f566cbe4b6c6' is created and registered. UUID: 26d5911e-9ddc-4bcf-9166-63097174966b Settings file: 'C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\boinc_0c84f566cbe4b6c6.vbox' 2025-02-08 23:36:39 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --description "CteNDm4eC16nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmfYQKDm1PxXpn_0" Exit Code: 0 Output: 2025-02-08 23:36:39 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --memory 4800 Exit Code: 0 Output: 2025-02-08 23:36:40 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --cpus 8 Exit Code: 0 Output: 2025-02-08 23:36:40 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-08 23:36:40 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-08 23:36:41 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-08 23:36:41 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-08 23:36:41 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --cableconnected1 on Exit Code: 0 Output: 2025-02-08 23:36:41 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --usb off Exit Code: 0 Output: 2025-02-08 23:36:42 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-08 23:36:42 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-08 23:36:42 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-08 23:36:42 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --clipboard disabled Exit Code: 0 Output: 2025-02-08 23:36:43 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --draganddrop disabled Exit Code: 0 Output: 2025-02-08 23:36:43 (14884): Command: VBoxManage -q storagectl "boinc_0c84f566cbe4b6c6" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-08 23:36:43 (14884): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-08 23:36:43 (14884): Command: VBoxManage -q storageattach "boinc_0c84f566cbe4b6c6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-08 23:36:44 (14884): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-08 23:36:45 (14884): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-08 23:36:45 (14884): Command: VBoxManage -q storageattach "boinc_0c84f566cbe4b6c6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-08 23:36:46 (14884): Command: VBoxManage -q storageattach "boinc_0c84f566cbe4b6c6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-08 23:36:46 (14884): Command: VBoxManage -q storageattach "boinc_0c84f566cbe4b6c6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-08 23:36:46 (14884): Command: VBoxManage -q storageattach "boinc_0c84f566cbe4b6c6" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-08 23:36:46 (14884): Command: VBoxManage -q bandwidthctl "boinc_0c84f566cbe4b6c6" add "boinc_0c84f566cbe4b6c6_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-08 23:36:47 (14884): Command: VBoxManage -q modifyvm "boinc_0c84f566cbe4b6c6" --natpf1 ",tcp,127.0.0.1,50201,,80" Exit Code: 0 Output: 2025-02-08 23:36:47 (14884): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-08 23:36:47 (14884): Command: VBoxManage -q sharedfolder add "boinc_0c84f566cbe4b6c6" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\17/shared" Exit Code: 0 Output: 2025-02-08 23:36:48 (14884): Command: VBoxManage -q startvm "boinc_0c84f566cbe4b6c6" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_0c84f566cbe4b6c6' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\17\boinc_0c84f566cbe4b6c6\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_0c84f566cbe4b6c6" to power on... 2025-02-08 23:36:48 (14884): Command: VBoxManage -q snapshot "boinc_0c84f566cbe4b6c6" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-08 23:36:48 (14884): Command: VBoxManage -q bandwidthctl "boinc_0c84f566cbe4b6c6" remove "boinc_0c84f566cbe4b6c6_net" Exit Code: 0 Output: 2025-02-08 23:36:49 (14884): Command: VBoxManage -q unregistervm "boinc_0c84f566cbe4b6c6" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 23:36:54 (14884): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN