Name | zlULDm29B16n9Rq4apOajLDm4fhM0noT9bVoFjIUDmzIMKDm72deLo_0 |
Workunit | 230229612 |
Created | 9 Feb 2025, 2:23:57 UTC |
Sent | 9 Feb 2025, 4:35:08 UTC |
Report deadline | 17 Feb 2025, 4:35:08 UTC |
Received | 9 Feb 2025, 5:36:15 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10848068 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 45.09 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.98 MB |
Peak swap size | 2.04 MB |
Peak disk usage | 326.20 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-08 22:35:51 (31124): Detected: vboxwrapper 26206 2025-02-08 22:35:51 (31124): Detected: BOINC client v7.24.1 2025-02-08 22:35:52 (31124): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-08 22:35:52 (31124): Successfully copied 'init_data.xml' to the shared directory. 2025-02-08 22:35:53 (31124): Create VM. (boinc_2ae18a11b744bbac, slot#17) 2025-02-08 22:35:53 (31124): Setting Memory Size for VM. (4800MB) 2025-02-08 22:35:54 (31124): Setting CPU Count for VM. (8) 2025-02-08 22:35:54 (31124): Setting Chipset Options for VM. 2025-02-08 22:35:54 (31124): Setting Graphics Controller Options for VM. 2025-02-08 22:35:54 (31124): Setting Boot Options for VM. 2025-02-08 22:35:55 (31124): Setting Network Configuration for NAT. 2025-02-08 22:35:55 (31124): Enabling VM Network Access. 2025-02-08 22:35:55 (31124): Disabling USB Support for VM. 2025-02-08 22:35:55 (31124): Disabling COM Port Support for VM. 2025-02-08 22:35:56 (31124): Disabling LPT Port Support for VM. 2025-02-08 22:35:56 (31124): Disabling Audio Support for VM. 2025-02-08 22:35:56 (31124): Disabling Clipboard Support for VM. 2025-02-08 22:35:56 (31124): Disabling Drag and Drop Support for VM. 2025-02-08 22:35:57 (31124): Adding storage controller(s) to VM. 2025-02-08 22:35:57 (31124): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-08 22:36:00 (31124): Adding VirtualBox Guest Additions to VM. 2025-02-08 22:36:00 (31124): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-08 22:36:00 (31124): forwarding host port 60964 to guest port 80 2025-02-08 22:36:01 (31124): Enabling remote desktop for VM. 2025-02-08 22:36:01 (31124): Required extension pack not installed, remote desktop not enabled. 2025-02-08 22:36:01 (31124): Enabling shared directory for VM. 2025-02-08 22:36:01 (31124): Starting VM using VBoxManage interface. (boinc_2ae18a11b744bbac, slot#17) 2025-02-08 22:36:02 (31124): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_2ae18a11b744bbac" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_2ae18a11b744bbac' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_2ae18a11b744bbac" to power on... 2025-02-08 22:36:02 (31124): VM failed to start. 2025-02-08 22:36:02 (31124): Could not start 2025-02-08 22:36:02 (31124): ERROR: VM failed to start 2025-02-08 22:36:02 (31124): Powering off VM. 2025-02-08 22:36:02 (31124): Deregistering VM. (boinc_2ae18a11b744bbac, slot#17) 2025-02-08 22:36:02 (31124): Removing network bandwidth throttle group from VM. 2025-02-08 22:36:02 (31124): Removing VM from VirtualBox. Hypervisor System Log: 00:00:20.630068 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:20.634705 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:22.177319 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:22.177729 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:22.177989 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:22.182444 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:22.182938 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:22.186550 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:22.449722 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:22.454058 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:22.716799 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:22.717500 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:22.721599 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:22.721814 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:22.723697 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:22.727292 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:22.727830 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:22.731398 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:22.975172 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:22.975568 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:22.976068 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:22.980762 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:23.239480 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:23.243704 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:23.504670 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:23.508861 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:24.027104 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:24.033217 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:24.287164 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:24.292019 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:24.292101 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:24.297539 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:24.557891 Launched VM: 818612720 pid: 33368 (0x8258) frontend: headless name: boinc_2ae18a11b744bbac 00:00:25.197377 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_2ae18a11b744bbac' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:25.197792 Watcher Reaper: Pid 33368 (0x8258) exited normally: 1 (0x1) 00:00:25.253246 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:25.301810 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" with version "1.19-windows" 00:00:25.306482 Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox" 00:00:25.559981 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:25.564423 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:25.564539 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:25.568458 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:25.569356 DeleteVM Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:25.573049 DeleteVM Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:30.583053 main VirtualBox: object deletion starts 00:00:30.583618 main HostDnsMonitor: shutting down ... 00:00:30.583648 main HostDnsMonitor: shut down 00:00:30.585089 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:30.585309 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: C\slots\17/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\17\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-08 22:35:53 (31124): Command: VBoxManage -q createvm --name "boinc_2ae18a11b744bbac" --basefolder "C:\ProgramData\BOINC\slots\17" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_2ae18a11b744bbac' is created and registered. UUID: 8d11731c-2c53-4ea5-a1aa-23040345a7eb Settings file: 'C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\boinc_2ae18a11b744bbac.vbox' 2025-02-08 22:35:53 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --description "zlULDm29B16n9Rq4apOajLDm4fhM0noT9bVoFjIUDmzIMKDm72deLo_0" Exit Code: 0 Output: 2025-02-08 22:35:54 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --memory 4800 Exit Code: 0 Output: 2025-02-08 22:35:54 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --cpus 8 Exit Code: 0 Output: 2025-02-08 22:35:54 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-08 22:35:54 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-08 22:35:55 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-08 22:35:55 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-08 22:35:55 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --cableconnected1 on Exit Code: 0 Output: 2025-02-08 22:35:55 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --usb off Exit Code: 0 Output: 2025-02-08 22:35:56 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-08 22:35:56 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-08 22:35:56 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-08 22:35:56 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --clipboard disabled Exit Code: 0 Output: 2025-02-08 22:35:57 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --draganddrop disabled Exit Code: 0 Output: 2025-02-08 22:35:57 (31124): Command: VBoxManage -q storagectl "boinc_2ae18a11b744bbac" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-08 22:35:57 (31124): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-08 22:35:58 (31124): Command: VBoxManage -q storageattach "boinc_2ae18a11b744bbac" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-08 22:35:58 (31124): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-08 22:35:59 (31124): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-08 22:35:59 (31124): Command: VBoxManage -q storageattach "boinc_2ae18a11b744bbac" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-08 22:36:00 (31124): Command: VBoxManage -q storageattach "boinc_2ae18a11b744bbac" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-08 22:36:00 (31124): Command: VBoxManage -q storageattach "boinc_2ae18a11b744bbac" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-08 22:36:00 (31124): Command: VBoxManage -q storageattach "boinc_2ae18a11b744bbac" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-08 22:36:00 (31124): Command: VBoxManage -q bandwidthctl "boinc_2ae18a11b744bbac" add "boinc_2ae18a11b744bbac_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-08 22:36:01 (31124): Command: VBoxManage -q modifyvm "boinc_2ae18a11b744bbac" --natpf1 ",tcp,127.0.0.1,60964,,80" Exit Code: 0 Output: 2025-02-08 22:36:01 (31124): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-08 22:36:01 (31124): Command: VBoxManage -q sharedfolder add "boinc_2ae18a11b744bbac" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\17/shared" Exit Code: 0 Output: 2025-02-08 22:36:02 (31124): Command: VBoxManage -q startvm "boinc_2ae18a11b744bbac" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_2ae18a11b744bbac' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\17\boinc_2ae18a11b744bbac\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_2ae18a11b744bbac" to power on... 2025-02-08 22:36:02 (31124): Command: VBoxManage -q snapshot "boinc_2ae18a11b744bbac" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-08 22:36:02 (31124): Command: VBoxManage -q bandwidthctl "boinc_2ae18a11b744bbac" remove "boinc_2ae18a11b744bbac_net" Exit Code: 0 Output: 2025-02-08 22:36:03 (31124): Command: VBoxManage -q unregistervm "boinc_2ae18a11b744bbac" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 22:36:08 (31124): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN