Name | CMS_3885042_1738432543.420742_0 |
Workunit | 230096636 |
Created | 1 Feb 2025, 17:55:46 UTC |
Sent | 1 Feb 2025, 18:11:53 UTC |
Report deadline | 4 Mar 2025, 18:11:53 UTC |
Received | 1 Feb 2025, 18:20:37 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10867829 |
Run time | 24 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 18.74 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 11.31 MB |
Peak swap size | 5.24 MB |
Peak disk usage | 0.74 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Erreur non sp�cifi�e (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-02-01 19:16:57 (19732): vboxwrapper version 26208 2025-02-01 19:16:57 (19732): BOINC client version: 8.0.2 2025-02-01 19:16:58 (19732): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-01 19:16:59 (19732): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-02-01 19:16:59 (19732): Successfully copied 'init_data.xml' to the shared directory. 2025-02-01 19:16:59 (19732): Create VM. (boinc_a7bef5d41f7e7679, slot#2) 2025-02-01 19:17:00 (19732): Setting Memory Size for VM. (4584MB) 2025-02-01 19:17:00 (19732): Setting CPU Count for VM. (4) 2025-02-01 19:17:00 (19732): Setting Chipset Options for VM. 2025-02-01 19:17:00 (19732): Setting Graphics Controller Options for VM. 2025-02-01 19:17:01 (19732): Setting Boot Options for VM. 2025-02-01 19:17:01 (19732): Setting Network Configuration for NAT. 2025-02-01 19:17:01 (19732): Enabling VM Network Access. 2025-02-01 19:17:02 (19732): Disabling USB Support for VM. 2025-02-01 19:17:02 (19732): Disabling COM Port Support for VM. 2025-02-01 19:17:02 (19732): Disabling LPT Port Support for VM. 2025-02-01 19:17:03 (19732): Disabling Audio Support for VM. 2025-02-01 19:17:03 (19732): Disabling Clipboard Support for VM. 2025-02-01 19:17:03 (19732): Disabling Drag and Drop Support for VM. 2025-02-01 19:17:04 (19732): Adding storage controller(s) to VM. 2025-02-01 19:17:04 (19732): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-02-01 19:17:07 (19732): Adding VirtualBox Guest Additions to VM. 2025-02-01 19:17:07 (19732): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-01 19:17:08 (19732): forwarding host port 49881 to guest port 80 2025-02-01 19:17:08 (19732): Enabling remote desktop for VM. 2025-02-01 19:17:09 (19732): Required extension pack not installed, remote desktop not enabled. 2025-02-01 19:17:09 (19732): Enabling shared directory for VM. 2025-02-01 19:17:09 (19732): Starting VM using VBoxManage interface. (boinc_a7bef5d41f7e7679, slot#2) 2025-02-01 19:17:14 (19732): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_a7bef5d41f7e7679" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_a7bef5d41f7e7679" to power on... 2025-02-01 19:17:14 (19732): VM failed to start. 2025-02-01 19:17:14 (19732): Could not start 2025-02-01 19:17:14 (19732): ERROR: VM failed to start 2025-02-01 19:17:14 (19732): Powering off VM. 2025-02-01 19:17:14 (19732): Deregistering VM. (boinc_a7bef5d41f7e7679, slot#2) 2025-02-01 19:17:15 (19732): Removing network bandwidth throttle group from VM. 2025-02-01 19:17:15 (19732): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.727782 Saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" with version "1.19-windows" 00:00:08.750955 Finished saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" 00:00:09.099925 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.102241 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.103627 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.103735 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.103825 Saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.107691 Finished saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" 00:00:09.107994 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.108041 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.108135 Saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.111217 Finished saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" 00:00:09.111803 Saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" with version "1.19-windows" 00:00:09.141167 Finished saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" 00:00:09.586823 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.589301 Saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" with version "1.19-windows" 00:00:09.611230 Finished saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" 00:00:10.100507 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.103577 Saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" with version "1.19-windows" 00:00:10.127279 Finished saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" 00:00:10.861480 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.863541 Saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" with version "1.19-windows" 00:00:10.889966 Finished saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" 00:00:11.227348 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:11.229384 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:11.235827 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.235916 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.244010 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.458855 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:11.462705 Launched VM: 2509039312 pid: 19488 (0x4c20) frontend: headless name: boinc_a7bef5d41f7e7679 00:00:16.204781 Saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" with version "1.19-windows" 00:00:16.226689 Finished saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" 00:00:16.860099 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.871950 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:17.001751 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:17.004223 Saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" with version "1.19-windows" 00:00:17.022329 Finished saving settings file "G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox" 00:00:17.280445 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:17.284783 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:17.284877 Saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.288336 Finished saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" 00:00:17.288447 Saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.291243 Finished saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" 00:00:17.292221 DeleteVM Saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.295080 DeleteVM Finished saving settings file "C:\Users\Yves\.VirtualBox\VirtualBox.xml" 00:00:22.302978 main VirtualBox: object deletion starts 00:00:22.304289 main HostDnsMonitor: shutting down ... 00:00:22.304320 main HostDnsMonitor: shut down 00:00:22.305680 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:22.305849 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: stered machine named 'boinc_a7bef5d41f7e7679' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp 2025-02-01 19:16:59 (19732): Command: VBoxManage -q createvm --name "boinc_a7bef5d41f7e7679" --basefolder "G:\slots\2" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_a7bef5d41f7e7679' is created and registered. UUID: 54d3900e-8299-4263-98ac-13f9723989f9 Settings file: 'G:\slots\2\boinc_a7bef5d41f7e7679\boinc_a7bef5d41f7e7679.vbox' 2025-02-01 19:17:00 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --description "CMS_3885042_1738432543.420742_0" Exit Code: 0 Output: 2025-02-01 19:17:00 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --memory 4584 Exit Code: 0 Output: 2025-02-01 19:17:00 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --cpus 4 Exit Code: 0 Output: 2025-02-01 19:17:00 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-01 19:17:01 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-01 19:17:01 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-01 19:17:01 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-01 19:17:02 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --cableconnected1 on Exit Code: 0 Output: 2025-02-01 19:17:02 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --usb off Exit Code: 0 Output: 2025-02-01 19:17:02 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-01 19:17:03 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-01 19:17:03 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --audio-enabled off Exit Code: 0 Output: 2025-02-01 19:17:03 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --clipboard disabled Exit Code: 0 Output: 2025-02-01 19:17:04 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --draganddrop disabled Exit Code: 0 Output: 2025-02-01 19:17:04 (19732): Command: VBoxManage -q storagectl "boinc_a7bef5d41f7e7679" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-01 19:17:04 (19732): Command: VBoxManage -q showhdinfo "G:\/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: G:\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-01 19:17:05 (19732): Command: VBoxManage -q storageattach "boinc_a7bef5d41f7e7679" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "G:\/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'G:\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-01 19:17:05 (19732): Command: VBoxManage -q showhdinfo "G:\/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: G:\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-01 19:17:05 (19732): Command: VBoxManage -q closemedium disk "G:\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-01 19:17:06 (19732): Command: VBoxManage -q showhdinfo "G:\/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: G:\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-01 19:17:06 (19732): Command: VBoxManage -q storageattach "boinc_a7bef5d41f7e7679" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "G:\/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-01 19:17:06 (19732): Command: VBoxManage -q storageattach "boinc_a7bef5d41f7e7679" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-01 19:17:07 (19732): Command: VBoxManage -q storageattach "boinc_a7bef5d41f7e7679" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "G:\/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-01 19:17:07 (19732): Command: VBoxManage -q storageattach "boinc_a7bef5d41f7e7679" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-01 19:17:08 (19732): Command: VBoxManage -q bandwidthctl "boinc_a7bef5d41f7e7679" add "boinc_a7bef5d41f7e7679_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-01 19:17:08 (19732): Command: VBoxManage -q modifyvm "boinc_a7bef5d41f7e7679" --natpf1 ",tcp,127.0.0.1,49881,,80" Exit Code: 0 Output: 2025-02-01 19:17:09 (19732): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-01 19:17:09 (19732): Command: VBoxManage -q sharedfolder add "boinc_a7bef5d41f7e7679" --name "shared" --hostpath "G:\slots\2/shared" Exit Code: 0 Output: 2025-02-01 19:17:14 (19732): Command: VBoxManage -q startvm "boinc_a7bef5d41f7e7679" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_a7bef5d41f7e7679" to power on... 2025-02-01 19:17:15 (19732): Command: VBoxManage -q snapshot "boinc_a7bef5d41f7e7679" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-01 19:17:15 (19732): Command: VBoxManage -q bandwidthctl "boinc_a7bef5d41f7e7679" remove "boinc_a7bef5d41f7e7679_net" Exit Code: 0 Output: 2025-02-01 19:17:15 (19732): Command: VBoxManage -q unregistervm "boinc_a7bef5d41f7e7679" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-02-01 19:17:20 (19732): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN