Name CMS_2610744_1737931995.057840_0
Workunit 229989083
Created 26 Jan 2025, 22:53:18 UTC
Sent 26 Jan 2025, 23:27:18 UTC
Report deadline 26 Feb 2025, 23:27:18 UTC
Received 26 Jan 2025, 23:30:18 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10670761
Run time 18 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 19.68 GFLOPS
Application version CMS Simulation v70.60 (vbox64_mt_mcore_cms)
windows_x86_64
Peak working set size 6.96 MB
Peak swap size 1.77 MB
Peak disk usage 0.74 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2025-01-26 17:27:21 (16164): vboxwrapper version 26208
2025-01-26 17:27:21 (16164): BOINC client version: 8.0.2
2025-01-26 17:27:22 (16164): Detected: VirtualBox VboxManage Interface (Version: 7.0.20)
2025-01-26 17:27:22 (16164): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2025-01-26 17:27:22 (16164): Successfully copied 'init_data.xml' to the shared directory.
2025-01-26 17:27:23 (16164): Create VM. (boinc_118edc5e3ab65005, slot#2)
2025-01-26 17:27:23 (16164): Setting Memory Size for VM. (4584MB)
2025-01-26 17:27:24 (16164): Setting CPU Count for VM. (4)
2025-01-26 17:27:24 (16164): Setting Chipset Options for VM.
2025-01-26 17:27:24 (16164): Setting Graphics Controller Options for VM.
2025-01-26 17:27:24 (16164): Setting Boot Options for VM.
2025-01-26 17:27:25 (16164): Setting Network Configuration for NAT.
2025-01-26 17:27:25 (16164): Enabling VM Network Access.
2025-01-26 17:27:25 (16164): Disabling USB Support for VM.
2025-01-26 17:27:25 (16164): Disabling COM Port Support for VM.
2025-01-26 17:27:26 (16164): Disabling LPT Port Support for VM.
2025-01-26 17:27:26 (16164): Disabling Audio Support for VM.
2025-01-26 17:27:26 (16164): Disabling Clipboard Support for VM.
2025-01-26 17:27:26 (16164): Disabling Drag and Drop Support for VM.
2025-01-26 17:27:27 (16164): Adding storage controller(s) to VM.
2025-01-26 17:27:27 (16164): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi)
2025-01-26 17:27:29 (16164): Adding VirtualBox Guest Additions to VM.
2025-01-26 17:27:29 (16164): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-01-26 17:27:30 (16164): forwarding host port 60188 to guest port 80
2025-01-26 17:27:30 (16164): Enabling remote desktop for VM.
2025-01-26 17:27:31 (16164): Enabling shared directory for VM.
2025-01-26 17:27:31 (16164): Starting VM using VBoxManage interface. (boinc_118edc5e3ab65005, slot#2)
2025-01-26 17:27:32 (16164): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_118edc5e3ab65005" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_118edc5e3ab65005' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_118edc5e3ab65005" to power on...

2025-01-26 17:27:32 (16164): VM failed to start.
2025-01-26 17:27:32 (16164): Could not start 
2025-01-26 17:27:32 (16164): ERROR: VM failed to start
2025-01-26 17:27:32 (16164): Powering off VM.
2025-01-26 17:27:32 (16164): Deregistering VM. (boinc_118edc5e3ab65005, slot#2)
2025-01-26 17:27:32 (16164): Removing network bandwidth throttle group from VM.
2025-01-26 17:27:32 (16164): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.963089          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.963192          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.969805          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:07.970143          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.970208          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:07.970303          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.977130          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:07.977655          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox" with version "1.19-windows"
00:00:07.986637          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox"
00:00:08.226807          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:08.229502          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox" with version "1.19-windows"
00:00:08.238584          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox"
00:00:08.495029          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:08.498664          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox" with version "1.19-windows"
00:00:08.507474          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox"
00:00:09.028290          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:09.033004          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox" with version "1.19-windows"
00:00:09.041992          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox"
00:00:09.305974          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:09.308996          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox" with version "1.19-windows"
00:00:09.318924          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox"
00:00:09.580331          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:09.582838          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={&#197;&#131;o extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0
00:00:09.591358          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.591486          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.601482          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.845795          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:09.861218          Launched VM: 3785077520 pid: 7292 (0x1c7c) frontend: headless name: boinc_118edc5e3ab65005
00:00:10.366171 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_118edc5e3ab65005' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.366711 Watcher  Reaper: Pid 7292 (0x1c7c) exited normally: 1 (0x1)
00:00:10.457103          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:10.459422          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.527950          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:10.530901          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox" with version "1.19-windows"
00:00:10.540705          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\boinc_118edc5e3ab65005.vbox"
00:00:10.795454          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:10.795848          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:10.795948          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.802646          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:10.802792          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.809424          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:10.810641 DeleteVM Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.818071 DeleteVM Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:15.833684 main     VirtualBox: object deletion starts
00:00:15.835126 main     HostDnsMonitor: shutting down ...
00:00:15.835182 main     HostDnsMonitor: shut down
00:00:15.836920 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:15.837282 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

1-26 17:27:24 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --cpus 4 
Exit Code: 0
Output:

2025-01-26 17:27:24 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-01-26 17:27:24 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-01-26 17:27:25 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-01-26 17:27:25 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-01-26 17:27:25 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --cableconnected1 on 
Exit Code: 0
Output:

2025-01-26 17:27:25 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --usb off 
Exit Code: 0
Output:

2025-01-26 17:27:26 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-01-26 17:27:26 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-01-26 17:27:26 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --audio-enabled off 
Exit Code: 0
Output:

2025-01-26 17:27:26 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --clipboard disabled 
Exit Code: 0
Output:

2025-01-26 17:27:27 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --draganddrop disabled 
Exit Code: 0
Output:

2025-01-26 17:27:27 (16164): 
Command: VBoxManage -q storagectl "boinc_118edc5e3ab65005" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-01-26 17:27:27 (16164): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" 
Exit Code: 0
Output:
UUID:           3da9ab36-1206-4cc3-8a9a-8d4138ab45c5
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-01-26 17:27:28 (16164): 
Command: VBoxManage -q storageattach "boinc_118edc5e3ab65005" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2025-01-26 17:27:28 (16164): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" 
Exit Code: 0
Output:
UUID:           3da9ab36-1206-4cc3-8a9a-8d4138ab45c5
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-01-26 17:27:28 (16164): 
Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-01-26 17:27:28 (16164): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" 
Exit Code: 0
Output:
UUID:           3da9ab36-1206-4cc3-8a9a-8d4138ab45c5
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-01-26 17:27:29 (16164): 
Command: VBoxManage -q storageattach "boinc_118edc5e3ab65005" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-01-26 17:27:29 (16164): 
Command: VBoxManage -q storageattach "boinc_118edc5e3ab65005" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-01-26 17:27:29 (16164): 
Command: VBoxManage -q storageattach "boinc_118edc5e3ab65005" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-01-26 17:27:29 (16164): 
Command: VBoxManage -q storageattach "boinc_118edc5e3ab65005" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-01-26 17:27:30 (16164): 
Command: VBoxManage -q bandwidthctl "boinc_118edc5e3ab65005" add "boinc_118edc5e3ab65005_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-01-26 17:27:30 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --natpf1 ",tcp,127.0.0.1,60188,,80" 
Exit Code: 0
Output:

2025-01-26 17:27:30 (16164): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:        6.1.16
Revision:       140961
Edition:        
Description:    Oracle Cloud Infrastructure integration, USB 2.0 and USB 3.0 Host Controller, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe.
VRDE Module:    VBoxVRDP
Crypto Module:  
Usable:         false
Why unusable:   VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='Helper version mismatch - expected 0x3 got 0x50000'

2025-01-26 17:27:31 (16164): 
Command: VBoxManage -q modifyvm "boinc_118edc5e3ab65005" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 60189 --vrde-property "Security/Method=RDP" 
Exit Code: 0
Output:

2025-01-26 17:27:31 (16164): 
Command: VBoxManage -q sharedfolder add "boinc_118edc5e3ab65005" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared"
Exit Code: 0
Output:

2025-01-26 17:27:32 (16164): 
Command: VBoxManage -q startvm "boinc_118edc5e3ab65005" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_118edc5e3ab65005' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\2\boinc_118edc5e3ab65005\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_118edc5e3ab65005" to power on...

2025-01-26 17:27:32 (16164): 
Command: VBoxManage -q snapshot "boinc_118edc5e3ab65005" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-01-26 17:27:32 (16164): 
Command: VBoxManage -q bandwidthctl "boinc_118edc5e3ab65005" remove "boinc_118edc5e3ab65005_net" 
Exit Code: 0
Output:

2025-01-26 17:27:32 (16164): 
Command: VBoxManage -q unregistervm "boinc_118edc5e3ab65005" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-01-26 17:27:38 (16164): called boinc_finish(1)

</stderr_txt>
]]>


©2025 CERN