Name | CMS_2506978_1737892369.302534_0 |
Workunit | 229978262 |
Created | 26 Jan 2025, 11:52:54 UTC |
Sent | 26 Jan 2025, 11:55:11 UTC |
Report deadline | 26 Feb 2025, 11:55:11 UTC |
Received | 26 Jan 2025, 12:24:59 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10670761 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 19.68 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 7.07 MB |
Peak swap size | 1.78 MB |
Peak disk usage | 0.74 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-01-26 06:20:45 (11608): vboxwrapper version 26208 2025-01-26 06:20:45 (11608): BOINC client version: 8.0.2 2025-01-26 06:20:46 (11608): Detected: VirtualBox VboxManage Interface (Version: 7.0.20) 2025-01-26 06:20:46 (11608): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-01-26 06:20:46 (11608): Successfully copied 'init_data.xml' to the shared directory. 2025-01-26 06:20:47 (11608): Create VM. (boinc_9afff5f72e296951, slot#3) 2025-01-26 06:20:47 (11608): Setting Memory Size for VM. (4584MB) 2025-01-26 06:20:48 (11608): Setting CPU Count for VM. (4) 2025-01-26 06:20:48 (11608): Setting Chipset Options for VM. 2025-01-26 06:20:48 (11608): Setting Graphics Controller Options for VM. 2025-01-26 06:20:48 (11608): Setting Boot Options for VM. 2025-01-26 06:20:49 (11608): Setting Network Configuration for NAT. 2025-01-26 06:20:49 (11608): Enabling VM Network Access. 2025-01-26 06:20:49 (11608): Disabling USB Support for VM. 2025-01-26 06:20:49 (11608): Disabling COM Port Support for VM. 2025-01-26 06:20:50 (11608): Disabling LPT Port Support for VM. 2025-01-26 06:20:50 (11608): Disabling Audio Support for VM. 2025-01-26 06:20:50 (11608): Disabling Clipboard Support for VM. 2025-01-26 06:20:51 (11608): Disabling Drag and Drop Support for VM. 2025-01-26 06:20:51 (11608): Adding storage controller(s) to VM. 2025-01-26 06:20:51 (11608): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-01-26 06:20:53 (11608): Adding VirtualBox Guest Additions to VM. 2025-01-26 06:20:53 (11608): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-01-26 06:20:54 (11608): forwarding host port 49926 to guest port 80 2025-01-26 06:20:54 (11608): Enabling remote desktop for VM. 2025-01-26 06:20:55 (11608): Enabling shared directory for VM. 2025-01-26 06:20:55 (11608): Starting VM using VBoxManage interface. (boinc_9afff5f72e296951, slot#3) 2025-01-26 06:20:56 (11608): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_9afff5f72e296951" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_9afff5f72e296951' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_9afff5f72e296951" to power on... 2025-01-26 06:20:56 (11608): VM failed to start. 2025-01-26 06:20:56 (11608): Could not start 2025-01-26 06:20:56 (11608): ERROR: VM failed to start 2025-01-26 06:20:56 (11608): Powering off VM. 2025-01-26 06:20:56 (11608): Deregistering VM. (boinc_9afff5f72e296951, slot#3) 2025-01-26 06:20:56 (11608): Removing network bandwidth throttle group from VM. 2025-01-26 06:20:56 (11608): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.710347 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:07.710498 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.716537 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:07.716820 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:07.716887 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:07.716980 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.722582 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:07.723023 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" with version "1.19-windows" 00:00:07.732082 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" 00:00:07.970301 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:07.973227 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" with version "1.19-windows" 00:00:07.982009 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" 00:00:08.240873 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:08.244495 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" with version "1.19-windows" 00:00:08.253562 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" 00:00:08.780443 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:08.785027 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" with version "1.19-windows" 00:00:08.794443 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" 00:00:09.044183 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.046685 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" with version "1.19-windows" 00:00:09.056001 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" 00:00:09.316360 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.318472 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.326373 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.326476 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.333908 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.573803 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.586341 Launched VM: 1105725600 pid: 14344 (0x3808) frontend: headless name: boinc_9afff5f72e296951 00:00:10.086050 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_9afff5f72e296951' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.086521 Watcher Reaper: Pid 14344 (0x3808) exited normally: 1 (0x1) 00:00:10.165980 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.167730 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.228897 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.231327 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" with version "1.19-windows" 00:00:10.241189 Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\boinc_9afff5f72e296951.vbox" 00:00:10.495845 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.496246 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.496348 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.505262 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:10.505393 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.511463 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:10.512661 DeleteVM Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.519122 DeleteVM Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:15.541756 main VirtualBox: object deletion starts 00:00:15.543013 main HostDnsMonitor: shutting down ... 00:00:15.543064 main HostDnsMonitor: shut down 00:00:15.544425 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.544747 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 1-26 06:20:48 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --cpus 4 Exit Code: 0 Output: 2025-01-26 06:20:48 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-01-26 06:20:48 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-01-26 06:20:49 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-01-26 06:20:49 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-01-26 06:20:49 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --cableconnected1 on Exit Code: 0 Output: 2025-01-26 06:20:49 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --usb off Exit Code: 0 Output: 2025-01-26 06:20:50 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --uart1 off --uart2 off Exit Code: 0 Output: 2025-01-26 06:20:50 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-01-26 06:20:50 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --audio-enabled off Exit Code: 0 Output: 2025-01-26 06:20:51 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --clipboard disabled Exit Code: 0 Output: 2025-01-26 06:20:51 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --draganddrop disabled Exit Code: 0 Output: 2025-01-26 06:20:51 (11608): Command: VBoxManage -q storagectl "boinc_9afff5f72e296951" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-01-26 06:20:51 (11608): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-26 06:20:52 (11608): Command: VBoxManage -q storageattach "boinc_9afff5f72e296951" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-01-26 06:20:52 (11608): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-26 06:20:52 (11608): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-26 06:20:52 (11608): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-26 06:20:53 (11608): Command: VBoxManage -q storageattach "boinc_9afff5f72e296951" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-26 06:20:53 (11608): Command: VBoxManage -q storageattach "boinc_9afff5f72e296951" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-01-26 06:20:53 (11608): Command: VBoxManage -q storageattach "boinc_9afff5f72e296951" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-26 06:20:53 (11608): Command: VBoxManage -q storageattach "boinc_9afff5f72e296951" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-01-26 06:20:54 (11608): Command: VBoxManage -q bandwidthctl "boinc_9afff5f72e296951" add "boinc_9afff5f72e296951_net" --type network --limit 1024G Exit Code: 0 Output: 2025-01-26 06:20:54 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --natpf1 ",tcp,127.0.0.1,49926,,80" Exit Code: 0 Output: 2025-01-26 06:20:54 (11608): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 6.1.16 Revision: 140961 Edition: Description: Oracle Cloud Infrastructure integration, USB 2.0 and USB 3.0 Host Controller, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe. VRDE Module: VBoxVRDP Crypto Module: Usable: false Why unusable: VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='Helper version mismatch - expected 0x3 got 0x50000' 2025-01-26 06:20:55 (11608): Command: VBoxManage -q modifyvm "boinc_9afff5f72e296951" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 49927 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-01-26 06:20:55 (11608): Command: VBoxManage -q sharedfolder add "boinc_9afff5f72e296951" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared" Exit Code: 0 Output: 2025-01-26 06:20:56 (11608): Command: VBoxManage -q startvm "boinc_9afff5f72e296951" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_9afff5f72e296951' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_9afff5f72e296951\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_9afff5f72e296951" to power on... 2025-01-26 06:20:56 (11608): Command: VBoxManage -q snapshot "boinc_9afff5f72e296951" list Exit Code: -108 Output: This machine does not have any snapshots 2025-01-26 06:20:56 (11608): Command: VBoxManage -q bandwidthctl "boinc_9afff5f72e296951" remove "boinc_9afff5f72e296951_net" Exit Code: 0 Output: 2025-01-26 06:20:56 (11608): Command: VBoxManage -q unregistervm "boinc_9afff5f72e296951" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-01-26 06:21:02 (11608): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN